The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors
Open accessAbstract
Biopotential signals are recorded mostly by using sticky, pre-gelled electrodes, which are not ideal for wearable, point-of-care monitoring where the usability of the personalized medical device depends critically on the level of comfort and wearability of the electrodes. We report a fully-wearable medical garment for mobile monitoring of cardiac biopotentials from the wrists or the neck with minimum restriction to regular clothing habits. The wearable prototype is based on elastic bands with graphene functionalized, textile electrodes and battery-powered, low-cost electronics for signal acquisition and wireless transmission. Comparison of the electrocardiogram (ECG) recordings obtained from the wearable prototype against conventional wet electrodes indicate excellent conformity and spectral coherence among the two signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Conductive Polymer Combined Silk Fiber Bundle for Bioelectrical Signal Recording
Tsukada, S., Nakashima, H., & Torimitsu, K. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033689 · Cited by 163
Cited by
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Fernández-Caramés, T., & Fraga-Lamas, P. (2018) · Electronics · doi:10.3390/electronics7120405 · Cited by 359
Graphene-based wearable sensors
Qiao, Y., Li, X., Hirtz, T., Deng, G., Wei, Y., Li, M., Ji, S., Wu, Q., Jian, J., Wu, F., et al. (2019) · Nanoscale · doi:10.1039/c9nr05532k · Cited by 158
Metadata
- Authors
- Yapici, M., & Alkhidir, T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-04-16
- Volume
- 17
- Issue
- 4
- Pages
- 875
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2607380958
- Cited by
- 166
- References
- 3
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors. https://app.cochat.ai/papers/10.3390/s17040875
- The paper
- Yapici, M., & Alkhidir, T. (2017). Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors. Sensors. https://doi.org/10.3390/s17040875
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.