Evaluation of Shifted Excitation Raman Difference Spectroscopy and Comparison to Computational Background Correction Methods Applied to Biochemical Raman Spectra

Open access

The DOI matches its Crossref record; 53 of the 56 references it cites were found in a registry or an index.

Abstract

Raman spectroscopy provides label-free biochemical information from tissue samples without complicated sample preparation. The clinical capability of Raman spectroscopy has been demonstrated in a wide range of in vitro and in vivo applications. However, a challenge for in vivo applications is the simultaneous excitation of auto-fluorescence in the majority of tissues of interest, such as liver, bladder, brain, and others. Raman bands are then superimposed on a fluorescence background, which can be several orders of magnitude larger than the Raman signal. To eliminate the disturbing fluorescence background, several approaches are available. Among instrumentational methods shifted excitation Raman difference spectroscopy (SERDS) has been widely applied and studied. Similarly, computational techniques, for instance extended multiplicative scatter correction (EMSC), have also been employed to remove undesired background contributions. Here, we present a theoretical and experimental evaluation and comparison of fluorescence background removal approaches for Raman spectra based on SERDS and EMSC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s17081724

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Baseline corrected spectra and spectra with simulated fluorescence backgrounds and shot noise levels: (a) Baseline corrected spectrum of lipids; (b) Baseline corrected spectrum of proteins; (c) Lipid spectra with added fluorescence intensities, i.e., 10 (blue), 8 (green) and 5 (red) times the maximal band of the lipid signal, including corresponding noise levels. The black spectrum is the lipid spectrum without fluorescence; (d) Protein spectra with added fluorescence intensities, i.e., 10 (blue), 8 (green) and 5 (red) times the maximal band of the lipid signal, including corresponding noise levels. The black spectrum is the protein spectrum without fluorescence; (e) Spectral bands and windows of the measured lipid spectrum, the black points are the maxima and the windows estimated by the Savitzky and Golay function; (f) SNR of the lipid spectra with fluorescence, the black spectrum is the SNR of the lipid spectrum, the red spectrum correspond to the SNR of the lipid spectrum with fluorescence 5 times the maximal band of the lipid signal, the blue spectrum is the SNR of the lipid spectrum with fluorescence factor 10 of the lipid signal.
Figure 1 Baseline corrected spectra and spectra with simulated fluorescence backgrounds and shot noise levels: (a) Baseline corrected spectrum of lipids; (b) Baseline corrected spectrum of proteins; (c) Lipid spectra with added fluorescence intensities, i.e., 10 (blue), 8 (green) and 5 (red) times the maximal band of the lipid signal, including corresponding noise levels. The black spectrum is the lipid spectrum without fluorescence; (d) Protein spectra with added fluorescence intensities, i.e., 10 (blue), 8 (green) and 5 (red) times the maximal band of the lipid signal, including corresponding noise levels. The black spectrum is the protein spectrum without fluorescence; (e) Spectral bands and windows of the measured lipid spectrum, the black points are the maxima and the windows estimated by the Savitzky and Golay function; (f) SNR of the lipid spectra with fluorescence, the black spectrum is the SNR of the lipid spectrum, the red spectrum correspond to the SNR of the lipid spectrum with fluorescence 5 times the maximal band of the lipid signal, the blue spectrum is the SNR of the lipid spectrum with fluorescence factor 10 of the lipid signal.CC BY · PubMed Central
Figure 2 Optimal shift: (a) Estimation by using the autocorrelation function of lipid and protein spectra (b) Estimation by using the 1-autocorrelation function of lipid and protein spectra; (c) Simulation of the difference spectra of lipid at 1 nm shift (green), 2 nm shift (black) and 4 nm shift (blue) with noise, the values are the percentage values of the retained signal; (d) Simulation of the difference spectra of lipid at 1 nm shift (green), 2 nm shift (black) and 4 nm shift (blue) without noise.
Figure 2 Optimal shift: (a) Estimation by using the autocorrelation function of lipid and protein spectra (b) Estimation by using the 1-autocorrelation function of lipid and protein spectra; (c) Simulation of the difference spectra of lipid at 1 nm shift (green), 2 nm shift (black) and 4 nm shift (blue) with noise, the values are the percentage values of the retained signal; (d) Simulation of the difference spectra of lipid at 1 nm shift (green), 2 nm shift (black) and 4 nm shift (blue) without noise.CC BY · PubMed Central
Figure 3 EMSC and SERDS spectra for lipid and protein: (a) Lipid spectrum without background (black); lipid spectrum with noise added (red, noise corresponds to the poison distribution of original spectrum and the added fluorescence five times the maximal band of the lipid signal); EMSC corrected lipid spectrum after adding a fluorescence background five times the maximal band of the lipid signal (green); absolute values of SERDS difference spectrum of lipid after shifting 4 nm (blue); (b) Protein spectrum without background (black); protein spectrum with noise added (red, this noise corresponds to the poison distribution of original spectrum and the added fluorescence five times the maximal band of the protein signal); EMSC corrected protein spectrum after having fluorescence background five times the maximal band of the protein signal (green); absolute values of SERDS difference spectrum of protein after shifting 4 nm (blue).
Figure 3 EMSC and SERDS spectra for lipid and protein: (a) Lipid spectrum without background (black); lipid spectrum with noise added (red, noise corresponds to the poison distribution of original spectrum and the added fluorescence five times the maximal band of the lipid signal); EMSC corrected lipid spectrum after adding a fluorescence background five times the maximal band of the lipid signal (green); absolute values of SERDS difference spectrum of lipid after shifting 4 nm (blue); (b) Protein spectrum without background (black); protein spectrum with noise added (red, this noise corresponds to the poison distribution of original spectrum and the added fluorescence five times the maximal band of the protein signal); EMSC corrected protein spectrum after having fluorescence background five times the maximal band of the protein signal (green); absolute values of SERDS difference spectrum of protein after shifting 4 nm (blue).CC BY · PubMed Central
Figure 4 Measured difference mean raw spectra of a lipid cluster at different excitation wavelength shifts (shift: 0.5 nm (black), 1.0 nm (red), 1.5 nm (green), 2.0 nm (blue)).
Figure 4 Measured difference mean raw spectra of a lipid cluster at different excitation wavelength shifts (shift: 0.5 nm (black), 1.0 nm (red), 1.5 nm (green), 2.0 nm (blue)).CC BY · PubMed Central
Figure 5 Comparison of measured lipid spectrum (a,d,g) and two protein spectra (b,e,h) and (c,f,i). Raw SERDS difference spectra (2 nm shift, (a–c), blue); EMSC corrected spectra at 785 nm ((d–f), green); 1st derivative of the EMSC corrected spectra at 785 nm ((g–i), green); the vertical black lines mark band positions.
Figure 5 Comparison of measured lipid spectrum (a,d,g) and two protein spectra (b,e,h) and (c,f,i). Raw SERDS difference spectra (2 nm shift, (a–c), blue); EMSC corrected spectra at 785 nm ((d–f), green); 1st derivative of the EMSC corrected spectra at 785 nm ((g–i), green); the vertical black lines mark band positions.CC BY · PubMed Central
Figure 6 Comparison of different SERDS data processing methods with a 2 nm shift for (a) measured lipid spectra and (b) measured protein spectra. For every method the mean spectrum (darker shade) along with its standard deviation is shown. Black: difference spectra obtained by subtraction of raw data; red: difference spectra after area normalization; green: difference spectra after z-score normalization; blue: difference spectra after subtraction optimization.
Figure 6 Comparison of different SERDS data processing methods with a 2 nm shift for (a) measured lipid spectra and (b) measured protein spectra. For every method the mean spectrum (darker shade) along with its standard deviation is shown. Black: difference spectra obtained by subtraction of raw data; red: difference spectra after area normalization; green: difference spectra after z-score normalization; blue: difference spectra after subtraction optimization.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Research works printed but not linked: 6

  1. Cadusch P.J. Hlaing M.M. Wade S.A. MxArthur S.L. Stoddart P.R. Improved methods for fluorescence background substraction from Raman spectra Mater. Sci. 2013 44 1587 1595
  2. Massart D.L. Vandeginste B.G.M. Buydens L.C.M. Jong S.D. Lewi P.J. Smeyers-Verbeke J. Data Handling in Science and Technology, Handbook of Chemometrics and Qualimetrics, Vols. 20A and 20B Elsevier Amsterdam, The Netherland 1997
  3. Vinzi V.E. Chin W.W. Henseler J. Wang H. Handbook of Partial Least Squares: Concepts, Methods and Applications Springer Science & Business Media Berlin, Germany 2010
  4. Dongy S. Melnik E.D. Ban V.S. Volodin B.L. A novel Method for practical implementation of shifted-excitation Raman difference spectroscopy (SERDS) Spectroscopy 2012 47 198 209
  5. Ryabchykov O. Spikes: Spike Correction of Raman Spectral Data R Package v 1.0 2016 · DOI
  6. Slobodan S. Pharmaceutical Applications of Raman Spectroscopy John Wiley & Sons, Inc. Sandwich, UK 2008

Cited by

See all 58

Metadata

Authors
Cordero, E., Korinth, F., Stiebing, C., Krafft, C., Schie, I., & Popp, J.
Affiliations
Leibniz Institute of Photonic Technology (DE)
Corresponding author
Schie, Iwan
Venue
Sensors
Publisher
MDPI AG
Published
2017-07-27
Volume
17
Issue
8
Pages
1724
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2741004015
Cited by
58
References
56
Citations by year
2026: 7 · 2025: 4 · 2024: 5 · 2023: 6 · 2022: 3 · 2021: 9 · 2020: 5 · 2019: 11 · 2018: 8
FWCI
3.85
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • RENATE (submittedVersion, cc-by-nc-nd)
  • RENATE (cc-by)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
Keywords
shifted excitation Raman difference spectroscopy, Raman spectroscopy, autofluorescence, in vivo Raman spectroscopy, liver tissue, bladder tissue, brain tissue
MeSH terms
Computers, Spectrometry, Fluorescence, Spectrum Analysis, Raman

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.