Evaluation of Shifted Excitation Raman Difference Spectroscopy and Comparison to Computational Background Correction Methods Applied to Biochemical Raman Spectra
Open accessThe DOI matches its Crossref record; 53 of the 56 references it cites were found in a registry or an index.
Abstract
Raman spectroscopy provides label-free biochemical information from tissue samples without complicated sample preparation. The clinical capability of Raman spectroscopy has been demonstrated in a wide range of in vitro and in vivo applications. However, a challenge for in vivo applications is the simultaneous excitation of auto-fluorescence in the majority of tissues of interest, such as liver, bladder, brain, and others. Raman bands are then superimposed on a fluorescence background, which can be several orders of magnitude larger than the Raman signal. To eliminate the disturbing fluorescence background, several approaches are available. Among instrumentational methods shifted excitation Raman difference spectroscopy (SERDS) has been widely applied and studied. Similarly, computational techniques, for instance extended multiplicative scatter correction (EMSC), have also been employed to remove undesired background contributions. Here, we present a theoretical and experimental evaluation and comparison of fluorescence background removal approaches for Raman spectra based on SERDS and EMSC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or software-based algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standard Normal Variate Transformation and De-Trending of Near-Infrared Diffuse Reflectance Spectra
Barnes, R. J., Dhanoa, M. S., & Lister, S. J. (1989) · Applied Spectroscopy · doi:10.1366/0003702894202201 · Cited by 3,867 · cited 1×
“z-score normalization/standard normal variate [64]:”
Raman Spectroscopy for Chemical Analysis
McCreery, R. L. (2000) · Wiley eBooks · doi:10.1002/0471721646 · Cited by 1,440
The Raman Effect: A Unified Treatment of the Theory of Raman Scattering by Molecules
Long, D. A. (2002) · Wiley eBooks · doi:10.1002/0470845767 · Cited by 1,108 · cited 1×
“The fluorescence scattering cross-section is usually several orders of magnitude higher than the Raman scattering cross-section [65,66].”
BackgroundAutomated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049 · cited 1×
“Computational methods include, for example, polynomial fitting [21], different least squares methods [22] and extended multiplicative scatter correction (EMSC) [23].”
MethodCell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887 · cited 1×
“Biological tissues can show significant auto-fluorescence [12], which depends on the excited fluorophores, the excitation wavelength, and is several magnitudes stronger”
Backgroundforecast: Forecasting Functions for Time Series and Linear Models
Hyndman, R., Athanasopoulos, G., Bergmeir, C., Caceres, G., Chhay, L., Kuroptev, K., Mücke, M., O'Hara-Wild, M., Petropoulos, F., Razbash, S., et al. (2009) · CRAN: Contributed Packages · doi:10.32614/cran.package.forecast · Cited by 791
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507 · cited 2×
“It is also based on a least squares fitting of pre-defined background spectra, but also including the fitting of pure components spectra [23].”
BackgroundMethodBaseline correction using asymmetrically reweighted penalized least squares smoothing
Baek, S.-J., Park, A., Ahn, Y.-J., & Choo, J. (2015) · The Analyst · doi:10.1039/c4an01061b · Cited by 477 · cited 1×
“Different least squares approaches have previously been implemented, such as for instance iterative least squares or weighted least squares [26,27].”
MethodShreve, A. P., Cherepy, N. J., & Mathies, R. A. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125122 · Cited by 312 · cited 1×
“The main limitation is the need of lock-in detection [34].”
BackgroundAn intelligent background‐correction algorithm for highly fluorescent samples in Raman spectroscopy
Zhang, Z., Chen, S., Liang, Y., Liu, Z., Zhang, Q., Ding, L., Ye, F., & Zhou, H. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2500 · Cited by 308
Advantages and limitations of Raman spectroscopy for molecular diagnostics: an update
Eberhardt, K., Stiebing, C., Matthäus, C., Schmitt, M., & Popp, J. (2015) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2015.1036744 · Cited by 282
Self-citationKrafft, C., Schmitt, M., Schie, I. W., Cialla‐May, D., Matthäus, C., Bocklitz, T., & Popp, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201607604 · Cited by 234 · cited 1×
“The ability to obtain specific biochemical information from biological samples without the need for labeling makes Raman spectroscopy attractive for many diagnostic applications in medicine [1,2].”
BackgroundSelf-citationCrow, P., Molckovsky, A., Stone, N., Uff, J., Wilson, B., & WongKeeSong, L.-M. (2005) · Urology · doi:10.1016/j.urology.2004.12.058 · Cited by 208
Krafft, C., Schie, I. W., Meyer, T., Schmitt, M., & Popp, J. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00564g · Cited by 198 · cited 1×
“The ability to obtain specific biochemical information from biological samples without the need for labeling makes Raman spectroscopy attractive for many diagnostic applications in medicine [1,2].”
BackgroundSelf-citationIn Vivo Bladder Cancer Diagnosis by High-Volume Raman Spectroscopy
Draga, R. O. P., Grimbergen, M. C. M., Vijverberg, P. L. M., Swol, C. F. P. V., Jonges, T. G. N., Kummer, J. A., & Ruud Bosch, J. L. H. (2010) · Analytical Chemistry · doi:10.1021/ac100448p · Cited by 196
Automated Fluorescence Rejection Using Shifted Excitation Raman Difference Spectroscopy
Zhao, J., Carrabba, M. M., & Allen, F. S. (2002) · Applied Spectroscopy · doi:10.1366/000370202760171491 · Cited by 186 · cited 2×
“The optimal shift distance has often been defined as the wavelength difference, which corresponds to the half-width of a Raman band [43].”
BackgroundBergholt, M. S., Zheng, W., Ho, K. Y., Teh, M., Yeoh, K. G., Yan So, J. B., Shabbir, A., & Huang, Z. (2014) · Gastroenterology · doi:10.1053/j.gastro.2013.11.002 · Cited by 159
Real-time Raman system for in vivo disease diagnosis
Motz, J. T., Gandhi, S. J., Scepanovic, O. R., Haka, A. S., Kramer, J. R., Dasari, R. R., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920247 · Cited by 139
Model‐based pre‐processing in Raman spectroscopy of biological samples
Liland, K. H., Kohler, A., & Afseth, N. K. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4886 · Cited by 132 · cited 1×
“One very promising framework for model-based background correction in Raman spectroscopy is EMSC [28].”
BackgroundStone, N., Prieto, M. C., Crow, P., Uff, J., & Ritchie, A. W. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0937-9 · Cited by 131
Gebrekidan, M. T., Knipfer, C., Stelzle, F., Popp, J., Will, S., & Braeuer, A. (2015) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4775 · Cited by 130
Self-citationOptimal algorithm for fluorescence suppression of modulated Raman spectroscopy
Mazilu, M., Luca, A. C. D., Riches, A., Herrington, C. S., & Dholakia, K. (2010) · Optics Express · doi:10.1364/oe.18.011382 · Cited by 126
The use of Raman spectroscopy to identify and characterize transitional cell carcinoma in vitro
Crow, P., Uff, J., Farmer, J. A., Wright, M., & Stone, N. (2004) · British Journal of Urology · doi:10.1111/j.1464-410x.2004.04852.x · Cited by 125
Online Fluorescence Suppression in Modulated Raman Spectroscopy
Luca, A. C. D., Mazilu, M., Riches, A., Herrington, C. S., & Dholakia, K. (2009) · Analytical Chemistry · doi:10.1021/ac9026737 · Cited by 113 · cited 1×
“Modulated Raman spectroscopy was introduced with a frequency-modulated excitation laser, continuous acquisition of Raman spectra, and without lock-in detection [35].”
MethodMulti-excitation Raman spectroscopy technique for fluorescence rejection
McCain, S. T., Willett, R. M., & Brady, D. J. (2008) · Optics Express · doi:10.1364/oe.16.010975 · Cited by 103
Automatization of spike correction in Raman spectra of biological samples
Ryabchykov, O., Bocklitz, T. W., Ramoji, A., Neugebauer, U., Foerster, M., Kroegel, C., Bauer, M. W., Kiehntopf, M., & Popp, J. (2016) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2016.03.024 · Cited by 100 · cited 1×
“All spectra were cleared from cosmic spikes [62,63].”
BackgroundSelf-citationAnalysis of luminescent samples using subtracted shifted Raman spectroscopy
Bell, S. E. J., Bourguignon, E., & Dennis, A. C. (1998) · The Analyst · doi:10.1039/a802802h · Cited by 78
A Prototype Hand-Held Raman Sensor for the in situ Characterization of Meat Quality
Schmidt, H., Sowoidnich, K., & Kronfeldt, H. (2010) · Applied Spectroscopy · doi:10.1366/000370210792081028 · Cited by 76
Separation of Raman spectra from fluorescence emission background by principal component analysis
Hasegawa, T., Nishijo, J., & Umemura, J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01427-x · Cited by 64 · cited 1×
“Further computational techniques used to separate the fluorescence background from Raman spectra are principal component analysis [29], and wavelets analysis [30].”
MethodCombined fiber probe for fluorescence lifetime and Raman spectroscopy
Dochow, S., Ma, D., Latka, I., Bocklitz, T. W., Hartl, B. A., Bec, J., Fatakdawala, H., Marple, E. T., Urmey, K., Wachsmann‐Hogiu, S., et al. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8800-5 · Cited by 60
Self-citationDevelopment of a time-gated system for Raman spectroscopy of biological samples
Knorr, F., Smith, Z. J., & Wachsmann-Hogiu, S. (2010) · Optics Express · doi:10.1364/oe.18.020049 · Cited by 59 · cited 1×
“However, the systems are highly complex, costly, and challenging to modify [33].”
BackgroundIdentification of Bladder Wall Layers by Raman Spectroscopy
de Jong, B. W. D., Schut, T. C. B., Wolffenbuttel, K. P., Nijman, J. M., Kok, D. J., & Puppels, G. J. (2002) · The Journal of Urology · doi:10.1016/s0022-5347(05)64411-4 · Cited by 56 · cited 1×
“Human tissue is mainly composed of proteins, lipids, nucleic acids, and carbohydrates [11].”
BackgroundModulated Raman Spectroscopy for Enhanced Cancer Diagnosis at the Cellular Level
Luca, A. C. D., Dholakia, K., & Mazilu, M. (2015) · Sensors · doi:10.3390/s150613680 · Cited by 52 · cited 1×
“These values are much higher than commonly reported [37,67,68].”
BackgroundSimple Reconstruction Algorithm for Shifted Excitation Raman Difference Spectroscopy
Matousek, P., Towrie, M., & Parker, A. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702054280757 · Cited by 51
Background correction in near-infrared spectra of plant extracts by orthogonal signal correction
Qu, H., Ou, D.-L., & Cheng, Y. (2005) · Journal of Zhejiang University. Science A · doi:10.1631/jzus.2005.b0838 · Cited by 49
Zięba‐Palus, J., & Michalska, A. (2014) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2014.06.007 · Cited by 49 · cited 1×
“By irradiating the sample with an excitation laser for a long period of time, a photolytic decomposition of the fluorescent interfering molecules is induced [14,15,32].”
BackgroundMacdonald, A. M., & Wyeth, P. (2006) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1510 · Cited by 48 · cited 1×
“By irradiating the sample with an excitation laser for a long period of time, a photolytic decomposition of the fluorescent interfering molecules is induced [14,15,32].”
BackgroundMartins, M. A. D. S., Ribeiro, D. G., Pereira dos Santos, E. A., Martin, A. A., Fontes, A., & Martinho, H. D. S. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000617 · Cited by 43
Osticioli, I., Zoppi, A., & Castellucci, E. (2007) · Applied Spectroscopy · doi:10.1366/000370207781540169 · Cited by 38
A portable shifted excitation Raman difference spectroscopy system: device and field demonstration
Maiwald, M., Müller, A., Sumpf, B., & Tränkle, G. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4953 · Cited by 37 · cited 1×
“These values are much higher than commonly reported [37,67,68].”
BackgroundMecozzi, M. (2014) · APCBEE Procedia · doi:10.1016/j.apcbee.2014.10.003 · Cited by 29 · cited 1×
“Next to manually deciding which areas should be used, automatic methods for curve fitting in chromatographic analysis have been proposed under high noise circumstances, which is a limiting factor for this method [24].”
MethodCapability of shifted excitation Raman difference spectroscopy under ambient daylight
Maiwald, M., Müller, A., Sumpf, B., Erbert, G., & Tränkle, G. (2015) · Applied Optics · doi:10.1364/ao.54.005520 · Cited by 28
Applications of Raman spectroscopy to the urinary bladder for cancer diagnostics
Kerr, L. T., Domijan, K., Cullen, I. M., & Hennelly, B. M. (2014) · Photonics and Lasers in Medicine · doi:10.1515/plm-2014-0004 · Cited by 28
Dochow, S., Bergner, N., Krafft, C., Clement, J. H., Mazilu, M., Praveen, B. B., Ashok, P. C., Marchington, R., Dholakia, K., & Popp, J. (2013) · Analytical Methods · doi:10.1039/c3ay40193f · Cited by 27 · cited 1×
“Since the positions of the Raman bands are used for the interpretation of Raman spectra, it was previously suggested that the optimal shift in excitation wavelength should correspond to the full width at half maximum of a relevant Raman band [43,44].”
BackgroundSelf-citationBackground Estimation of Biomedical Raman Spectra Using a Geometric Approach
Kourkoumelis, N., Polymeros, A., & Tzaphlidou, M. (2012) · Journal of Spectroscopy · doi:10.1155/2012/530791 · Cited by 27 · cited 1×
“However, the transformation of the signal into frequency bands may result in distortion in some spectral areas [19,31].”
BackgroundDesign and first applications of a flexible Raman micro-spectroscopic system for biological imaging
Kiselev, R., Schie, I. W., Aškrabić, S., Krafft, C., & Popp, J. (2016) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-160141 · Cited by 25 · cited 1×
“The setup has been previously described [61].”
Self-citationAsfour, H., Swift, L., Sarvazyan, N. A., Doroslovacki, M. I., & Kay, M. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2143713 · Cited by 24 · cited 1×
“Further computational techniques used to separate the fluorescence background from Raman spectra are principal component analysis [29], and wavelets analysis [30].”
MethodOshima, Y., Komachi, Y., Furihata, C., Tashiro, H., & Sato, H. (2006) · Applied Spectroscopy · doi:10.1366/000370206778397344 · Cited by 22
Clinical Raman measurements under special ambient lighting illumination
Zhao, J., Short, M. A., Braun, T., Lui, H., McLean, D. I., & Zeng, H. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.11.111609 · Cited by 10
polynom: A Collection of Functions to Implement a Class for Univariate Polynomial Manipulations
Venables, B., Hornik, K., & Maechler, M. (1999) · doi:10.32614/cran.package.polynom · Cited by 9
Multiscale Reconstruction for Photon-Limited Shifted Excitation Raman Spectroscopy
Willett, R. M. (2007) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2007.366809 · Cited by 7
Raman spectra of single cells with autofluorescence suppression by modulated wavelength excitation
Krafft, C., Dochow, S., Bergner, N., Clement, J. H., Praveen, B. B., Mazilu, M., Marchington, R., Dholakia, K., & Popp, J. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.908564 · Cited by 2
Self-citation
Research works printed but not linked: 6
- Cadusch P.J. Hlaing M.M. Wade S.A. MxArthur S.L. Stoddart P.R. Improved methods for fluorescence background substraction from Raman spectra Mater. Sci. 2013 44 1587 1595
- Massart D.L. Vandeginste B.G.M. Buydens L.C.M. Jong S.D. Lewi P.J. Smeyers-Verbeke J. Data Handling in Science and Technology, Handbook of Chemometrics and Qualimetrics, Vols. 20A and 20B Elsevier Amsterdam, The Netherland 1997
- Vinzi V.E. Chin W.W. Henseler J. Wang H. Handbook of Partial Least Squares: Concepts, Methods and Applications Springer Science & Business Media Berlin, Germany 2010
- Dongy S. Melnik E.D. Ban V.S. Volodin B.L. A novel Method for practical implementation of shifted-excitation Raman difference spectroscopy (SERDS) Spectroscopy 2012 47 198 209
- Ryabchykov O. Spikes: Spike Correction of Raman Spectral Data R Package v 1.0 2016 · DOI
- Slobodan S. Pharmaceutical Applications of Raman Spectroscopy John Wiley & Sons, Inc. Sandwich, UK 2008
Cited by
In-vivo Raman spectroscopy: from basics to applications
Cordero, E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.7.071210 · Cited by 195
Self-citationThe role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“These approaches are at an early technology development stage, appear to offer no compelling advantage over spontaneous Raman at higher wavelengths or softwarebased algorithms for fluorescence suppression, and appear to be currently limited to off-line or laboratory use [22, 26].”
BackgroundMethodArtifacts and Anomalies in Raman Spectroscopy: A Review on Origins and Correction Procedures
Vulchi, R. T., Morgunov, V., Junjuri, R., & Bocklitz, T. W. (2024) · Molecules · doi:10.3390/molecules29194748 · Cited by 123
“Genetic algorithm (GA) [145,146] Based on natural selection and evolution principles, GA optimizes the parameters of methods like ALS, spline smoothing, and polynomial fitting.”
MethodLi, Z., Li, Z., Chen, Q., Ramos, A., Zhang, J., Boudreaux, J. P., Thiagarajan, R., Bren‐Mattison, Y., Dunham, M. E., McWhorter, A. J., et al. (2021) · Neural Networks · doi:10.1016/j.neunet.2021.09.006 · Cited by 86
Surface-Enhanced Raman Scattering Detection of Fipronil Pesticide Adsorbed on Silver Nanoparticles
Ly, N. H., Nguyen, T. H., Ngo, D. N., Kim, Y., & Joo, S. (2019) · Sensors · doi:10.3390/s19061355 · Cited by 47
“Therefore, the development and application of systems based on combinations of SERS and DFT calculations are a current hot topic that has contributed to a better understanding of the phenomena related to detection and monitoring at very low concentrations—especially at physiological levels [18,22,24].”
Background
Metadata
- Authors
- Cordero, E., Korinth, F., Stiebing, C., Krafft, C., Schie, I., & Popp, J.
- Affiliations
- Leibniz Institute of Photonic Technology (DE)
- Corresponding author
- Schie, Iwan
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-07-27
- Volume
- 17
- Issue
- 8
- Pages
- 1724
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC5579526
- OpenAlex
- W2741004015
- Cited by
- 58
- References
- 56
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 5 · 2023: 6 · 2022: 3 · 2021: 9 · 2020: 5 · 2019: 11 · 2018: 8
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- RENATE (submittedVersion, cc-by-nc-nd)
- RENATE (cc-by)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Keywords
- shifted excitation Raman difference spectroscopy, Raman spectroscopy, autofluorescence, in vivo Raman spectroscopy, liver tissue, bladder tissue, brain tissue
- MeSH terms
- Computers, Spectrometry, Fluorescence, Spectrum Analysis, Raman
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.