The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Review and Analysis of Peak Tracking Techniques for Fiber Bragg Grating Sensors
Open accessAbstract
Fiber Bragg Grating (FBG) sensors are among the most popular elements for fiber optic sensor networks used for the direct measurement of temperature and strain. Modern FBG interrogation setups measure the FBG spectrum in real-time, and determine the shift of the Bragg wavelength of the FBG in order to estimate the physical parameters. The problem of determining the peak wavelength of the FBG from a spectral measurement limited in resolution and noise, is referred as the peak-tracking problem. In this work, the several peak-tracking approaches are reviewed and classified, outlining their algorithmic implementations: the methods based on direct estimation, interpolation, correlation, resampling, transforms, and optimization are discussed in all their proposed implementations. Then, a simulation based on coupled-mode theory compares the performance of the main peak-tracking methods, in terms of accuracy and signal to noise ratio resilience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-resolution frequency-wavenumber spectrum analysis
Capon, J. (1969) · Proceedings of the IEEE · doi:10.1109/proc.1969.7278 · Cited by 6,374
Kersey, A. D., Davis, M. A., Patrick, H. J., LeBlanc, M., Koo, K. P., Askins, C. G., Putnam, M. A., & Friebele, E. J. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618377 · Cited by 3,599
Erdogan, T. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618322 · Cited by 3,369
Formation of Bragg gratings in optical fibers by a transverse holographic method
Meltz, G., Morey, W. W., & Glenn, W. H. (1989) · Optics Letters · doi:10.1364/ol.14.000823 · Cited by 1,808
In-fibre Bragg grating sensors
Rao, Y.-J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/4/002 · Cited by 1,606
Fiber Bragg Grating Sensors for Harsh Environments
Mihailov, S. J. (2012) · Sensors · doi:10.3390/s120201898 · Cited by 830
Fiber Optic Sensors: An Introduction for Engineers and Scientists
(2011) · Wiley eBooks · doi:10.1002/9781118014103 · Cited by 783
Fiber Optic Sensors in Structural Health Monitoring
Lopez-Higuera, J. M., Rodriguez Cobo, L., Quintela Incera, A., & Cobo, A. (2011) · Journal of Lightwave Technology · doi:10.1109/jlt.2011.2106479 · Cited by 783
Kinet, D., Mégret, P., Goossen, K., Qiu, L., Heider, D., & Caucheteur, C. (2014) · Sensors · doi:10.3390/s140407394 · Cited by 523
Chan, T. H. T., Yu, L., Tam, H. Y., Ni, Y. Q., Liu, S. Y., Chung, W. H., & Cheng, L. K. (2006) · Engineering Structures · doi:10.1016/j.engstruct.2005.09.018 · Cited by 484
Cited by
Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2988692 · Cited by 128
Self-citation
Metadata
- Authors
- Tosi, D.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-10-17
- Volume
- 17
- Issue
- 10
- Pages
- 2368
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2766940139
- Cited by
- 266
- References
- 27
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review and Analysis of Peak Tracking Techniques for Fiber Bragg Grating Sensors. https://app.cochat.ai/papers/10.3390/s17102368
- The paper
- Tosi, D. (2017). Review and Analysis of Peak Tracking Techniques for Fiber Bragg Grating Sensors. Sensors. https://doi.org/10.3390/s17102368
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.