Recent Research and Developing Trends of Wearable Sensors for Detecting Blood Pressure
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Blood pressure is considered an index to measure a person’s health or state. The IEEE published a standard for wearable cuffless blood pressure measuring devices, which was certified as IEEE1708 on 26 August 2014, and, according to this standard, the development of wearable devices based on blood pressure is expected in the future. Considering this, blood pressure should be detectable all the time and everywhere, and this can help improve health consciousness. In this review, we introduce the recent development of wearable blood pressure measuring devices and research trends, and present the future prospects for blood pressure measuring devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899 · cited 1×
“It is now commercially available as the Finometer and Portapres recorders and has been validated in several studies against intra-arterial pressures [21,22].”
MethodPotential U.S. Population Impact of the 2017 ACC/AHA High Blood Pressure Guideline
Muntner, P., Carey, R. M., Gidding, S., Jones, D. W., Taler, S. J., Wright, J. T., & Whelton, P. K. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.073 · Cited by 339
Cited by
Fernández-Caramés, T., & Fraga-Lamas, P. (2018) · Electronics · doi:10.3390/electronics7120405 · Cited by 359
An intelligent healthcare monitoring framework using wearable sensors and social networking data
Ali, F., El-Sappagh, S., Islam, S. M. R., Ali, A., Attique, M., Imran, M., & Kwak, K.-S. (2021) · Future Generation Computer Systems · doi:10.1016/j.future.2020.07.047 · Cited by 355
Progress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
Mukkamala, R., Yavarimanesh, M., Natarajan, K., Hahn, J.-O., Kyriakoulis, K. G., Avolio, A. P., & Stergiou, G. S. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17747 · Cited by 211
Wearables in cardiology: Here to stay
Dagher, L., Shi, H., Zhao, Y., & Marrouche, N. F. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.02.023 · Cited by 107
Metadata
- Authors
- Arakawa, T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-08-23
- Volume
- 18
- Issue
- 9
- Pages
- 2772
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2888571403
- Cited by
- 100
- References
- 2
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.