The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optical Biosensors for Label-Free Detection of Small Molecules
Open accessAbstract
Label-free optical biosensors are an intriguing option for the analyses of many analytes, as they offer several advantages such as high sensitivity, direct and real-time measurement in addition to multiplexing capabilities. However, development of label-free optical biosensors for small molecules can be challenging as most of them are not naturally chromogenic or fluorescent, and in some cases, the sensor response is related to the size of the analyte. To overcome some of the limitations associated with the analysis of biologically, pharmacologically, or environmentally relevant compounds of low molecular weight, recent advances in the field have improved the detection of these analytes using outstanding methodology, instrumentation, recognition elements, or immobilization strategies. In this review, we aim to introduce some of the latest developments in the field of label-free optical biosensors with the focus on applications with novel innovations to overcome the challenges related to small molecule detection. Optical label-free methods with different transduction schemes, including evanescent wave and optical fiber sensors, surface plasmon resonance, surface-enhanced Raman spectroscopy, and interferometry, using various biorecognition elements, such as antibodies, aptamers, enzymes, and bioinspired molecularly imprinted polymers, are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179
Cited by
Molecularly Imprinted Polymers: Antibody Mimics for Bioimaging and Therapy
Haupt, K., Medina Rangel, P. X., & Bui, B. T. S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00428 · Cited by 561
Metasurface Micro/Nano-Optical Sensors: Principles and Applications
Qin, J., Jiang, S., Wang, Z., Cheng, X., Li, B., Shi, Y., Tsai, D. P., Liu, A. Q., Huang, W., & Zhu, W. (2022) · ACS Nano · doi:10.1021/acsnano.2c03310 · Cited by 359
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Metadata
- Authors
- Peltomaa, R., Glahn-Martínez, B., Benito-Peña, E., & Moreno-Bondi, M. C.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-11-24
- Volume
- 18
- Issue
- 12
- Pages
- 4126
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2903132245
- Cited by
- 249
- References
- 1
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Biosensors for Label-Free Detection of Small Molecules. https://app.cochat.ai/papers/10.3390/s18124126
- The paper
- Peltomaa, R., Glahn-Martínez, B., Benito-Peña, E., & Moreno-Bondi, M. C. (2018). Optical Biosensors for Label-Free Detection of Small Molecules. Sensors. https://doi.org/10.3390/s18124126
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.