CoChat

A New Wearable Device for Blood Pressure Estimation Using Photoplethysmogram

Open access
Lazazzera, Remo, Belhaj, Yassir, Carrault, Guy · 2019 · Sensors
Cited by 121

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

We present a novel smartwatch, CareUp ® , for estimating the Blood Pressure (BP) in real time. It consists of two pulse oximeters: one placed on the back and one on the front of the device. Placing the index finger on the front oximeter starts the acquisition of two photoplethysmograms (PPG); the signals are then filtered and cross-correlated to obtain a Time Delay between them, called Pulse Transit Time (PTT). The Heart Rate (HR) (estimated from the finger PPG) and the PTT are then input in a linear model to give an estimation of the Systolic and Diastolic BP. The performance of the smartwatch in measuring BP have been validated in the Institut Coeur Paris Centre Turin (ICPC), using a sphygmomanometer, on 44 subjects. During the validation, the measures of the CareUp ® were compared to those of two oscillometry-based devices already available on the market: Thuasne ® and Magnien ® . The results showed an accuracy comparable to the oscillometry-based devices and they almost agreed with the American Association for the Advancement of Medical Instrumentation standard for non-automated sphygmomanometers. The integration of the BP estimation algorithm in the smartwatch makes the CareUp ® an easy-to-use, wearable device for monitoring the BP in real time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s19112557

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 121

Metadata

Authors
Lazazzera, R., Belhaj, Y., & Carrault, G.
Venue
Sensors
Publisher
MDPI AG
Published
2019-06-04
Volume
19
Issue
11
Pages
2557
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2948321969
Cited by
121
References
6
FWCI
6.14
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.