Detecting Moments of Stress from Measurements of Wearable Physiological Sensors
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
There is a rich repertoire of methods for stress detection using various physiological signals and algorithms. However, there is still a gap in research efforts moving from laboratory studies to real-world settings. A small number of research has verified when a physiological response is a reaction to an extrinsic stimulus of the participant’s environment in real-world settings. Typically, physiological signals are correlated with the spatial characteristics of the physical environment, supported by video records or interviews. The present research aims to bridge the gap between laboratory settings and real-world field studies by introducing a new algorithm that leverages the capabilities of wearable physiological sensors to detect moments of stress (MOS). We propose a rule-based algorithm based on galvanic skin response and skin temperature, combing empirical findings with expert knowledge to ensure transferability between laboratory settings and real-world field studies. To verify our algorithm, we carried out a laboratory experiment to create a “gold standard” of physiological responses to stressors. We validated the algorithm in real-world field studies using a mixed-method approach by spatially correlating the participant’s perceived stress, geo-located questionnaires, and the corresponding real-world situation from the video. Results show that the algorithm detects MOS with 84% accuracy, showing high correlations between measured (by wearable sensors), reported (by questionnaires and eDiary entries), and recorded (by video) stress events. The urban stressors that were identified in the real-world studies originate from traffic congestion, dangerous driving situations, and crowded areas such as tourist attractions. The presented research can enhance stress detection in real life and may thus foster a better understanding of circumstances that bring about physiological stress in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Habituation: a model phenomenon for the study of neuronal substrates of behavior
Thompson, R. F., & Spencer, W. A. (1966) · Psychological Review · doi:10.1037/h0022681 · Cited by 2,608 · cited 1×
“This concurs with the phenomenon of habituation, describing the reduction of the physiological responses elicited by repeated exposure to a monotypic stressor [80].”
BackgroundBoucsein, W. (2012) · doi:10.1007/978-1-4614-1126-0 · Cited by 2,526
Toward machine emotional intelligence: analysis of affective physiological state
Picard, R. W., Vyzas, E., & Healey, J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.954607 · Cited by 2,334 · cited 3×
“Moreover, most of the researchers who have achieved similar or higher accuracies, mainly in laboratory settings, have used more physiological signals [25,44,46] while we use only GSR and ST making our approach excelling in terms of data collection requirements.”
BackgroundMethodDetecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Discriminating Stress From Cognitive Load Using a Wearable EDA Device
Setz, C., Arnrich, B., Schumm, J., La Marca, R., Troster, G., & Ehlert, U. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036164 · Cited by 742 · cited 3×
“[44] used only GSR, and they achieved a higher accuracy (82.”
BackgroundMethodPreference for Nature in Urbanized Societies: Stress, Restoration, and the Pursuit of Sustainability
Van Den Berg, A. E., Hartig, T., & Staats, H. (2007) · Journal of Social Issues · doi:10.1111/j.1540-4560.2007.00497.x · Cited by 727
Cardiovascular, electrodermal, and respiratory response patterns to fear‐ and sadness‐inducing films
Kreibig, S. D., Wilhelm, F. H., Roth, W. T., & Gross, J. J. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00550.x · Cited by 495 · cited 1×
“[56] distinguish fear, sadness, and calm, inducing films.”
Self-citationThe effect of stress on core and peripheral body temperature in humans
Vinkers, C. H., Penning, R., Hellhammer, J., Verster, J. C., Klaessens, J. H. G. M., Olivier, B., & Kalkman, C. J. (2013) · Stress · doi:10.3109/10253890.2013.807243 · Cited by 220 · cited 1×
“However, in some cases, it may show greater variations because of extreme environmental temperature, fever, malnutrition, physical exertion, and physiological changes such as vasospasm [34].”
BackgroundTowards the smart sensors based human emotion recognition
Quazi, M. T., Mukhopadhyay, S. C., Suryadevara, N. K., & Huang, Y. M. (2012) · 2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings · doi:10.1109/i2mtc.2012.6229646 · Cited by 49
Cited by
Human stress classification during public speaking using physiological signals
Arsalan, A., & Majid, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104377 · Cited by 77
Human-Centric Data Science for Urban Studies
Resch, B., & Szell, M. (2019) · ISPRS International Journal of Geo-Information · doi:10.3390/ijgi8120584 · Cited by 32
Self-citationBolinski, F., Etzelmüller, A., De Witte, N. A. J., van Beurden, C., Debard, G., Bonroy, B., Cuijpers, P., Riper, H., & Kleiboer, A. (2021) · Behaviour Research and Therapy · doi:10.1016/j.brat.2021.103877 · Cited by 23
Metadata
- Authors
- Kyriakou, K., Resch, B., Sagl, G., Petutschnig, A., Werner, C., Niederseer, D., Liedlgruber, M., Wilhelm, F., Osborne, T., & Pykett, J.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-09-03
- Volume
- 19
- Issue
- 17
- Pages
- 3805
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2971526326
- Cited by
- 239
- References
- 11
- FWCI
- 30.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.