Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The presence of small amounts of human serum albumin (HSA) in urine or microalbuminuria (30–300 µg/mL) is a valuable clinical biomarker for the early detection of chronic kidney disease (CKD). Herein, we report on the development of an inexpensive and disposable immunosensor for the sensitive, specific, and label-free detection of HSA using electrochemical impedance spectroscopy (EIS). We have utilized a simple one-step screen-printing protocol to fabricate the carbon-based three-electrode system on flexible plastic substrates. To enable efficient antibody immobilization and improved sensitivity, the carbon working electrode was sequentially modified with electropolymerized polyaniline (PANI) and electrodeposited gold nanocrystals (AuNCs). The PANI matrix serves as an interconnected nanostructured scaffold for homogeneous distribution of AuNCs and the resulting PANI/AuNCs nanocomposite synergically improved the immunosensor response. The PANI/AuNCs-modified working electrode surface was characterized using scanning electron microscopy (SEM) and the electrochemical response at each step was analyzed using EIS in a ferri/ferrocyanide redox probe solution. The normalized impedance variation during immunosensing increased linearly with HSA concentration in the range of 3–300 µg/mL and a highly repeatable response was observed for each concentration. Furthermore, the immunosensor displayed high specificity when tested using spiked sample solutions containing different concentrations of actin protein and J82 cell lysate (a complex fluid containing a multitude of interfering proteins). Consequently, these experimental results confirm the feasibility of the proposed immunosensor for early diagnosis and prognosis of CKD at the point of care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Milo, R. (2013) · BioEssays · doi:10.1002/bies.201300066 · Cited by 614
Research works printed but not linked: 35
- Luyckx, 2018, The global burden of kidney disease and the sustainable development goals, Bull. World Health Organ., 96, 414, 10.2471/BLT.17.206441 · DOI · Paper page
- Hill, N.R., Fatoba, S.T., Oke, J.L., Hirst, J.A., O’Callaghan, C.A., Lasserson, D.S., and Hobbs, F.R. (2016). Global prevalence of chronic kidney disease—A systematic review and meta-analysis. PLoS ONE, 11. · DOI · Paper page
- Murray, 2015, Global, regional, and national disability-adjusted life years (DALYs) for 306 diseases and injuries and healthy life expectancy (HALE) for 188 countries, 1990–2013: Quantifying the epidemiological transition, Lancet, 386, 2145, 10.1016/S0140-6736(15)61340-X · DOI · Paper page
- American Diabetes Association (2004). Nephropathy in diabetes. Diabetes Care, 27, s79–s83. · DOI · Paper page
- Hillege, 2002, Urinary albumin excretion predicts cardiovascular and noncardiovascular mortality in general population, Circulation, 106, 1777, 10.1161/01.CIR.0000031732.78052.81 · DOI · Paper page
- Souto, 2017, Electrochemical biosensors in point-of-care devices: Recent advances and future trends, ChemElectroChem, 4, 778, 10.1002/celc.201600758 · DOI · Paper page
- Gauglitz, 2014, Point-of-care platforms, Annu. Rev. Anal. Chem., 7, 297, 10.1146/annurev-anchem-071213-020332 · DOI
- Guo, 2018, Smartphone-powered electrochemical biosensing dongle for emerging medical IoTs application, IEEE Trans. Ind. Inform., 14, 2592, 10.1109/TII.2017.2777145 · DOI
- Xu, 2018, Automatic smartphone-based microfluidic biosensor system at the point of care, Biosens. Bioelectron., 110, 78, 10.1016/j.bios.2018.03.018 · DOI · Paper page
- Ronkainen, 2010, Electrochemical biosensors, Chem. Soc. Rev., 39, 1747, 10.1039/b714449k · DOI · Paper page
- Felix, 2018, Electrochemical immunosensors—A powerful tool for analytical applications, Biosens. Bioelectron., 102, 470, 10.1016/j.bios.2017.11.029 · DOI · Paper page
- Moina, C., and Ybarra, G. (2012). Fundamentals and applications of immunosensors. Advances in Immunoassay Technology, IntechOpen. · DOI
- Singh, 2010, Minimizing nonspecific adsorption in protein biosensors that utilize electrochemical impedance spectroscopy, J. Electrochem. Soc., 157, J334, 10.1149/1.3478635 · DOI
- Lisdat, 2008, The use of electrochemical impedance spectroscopy for biosensing, Anal. Bioanal. Chem., 391, 1555, 10.1007/s00216-008-1970-7 · DOI · Paper page
- Chuang, 2016, Immunosensor for the ultrasensitive and quantitative detection of bladder cancer in point of care testing, Biosens. Bioelectron., 84, 126, 10.1016/j.bios.2015.12.103 · DOI
- Shaikh, 2018, based immunosensor utilizing dielectrophoretic trapping of microprobes for quantitative and label free detection using electrochemical impedance spectroscopy, Biomicrofluidics, 12, 064102, 10.1063/1.5057731 · doi:10.1063/1.5057731
- Taleat, 2014, Screen-printed electrodes for biosensing: A review (2008–2013), Microchim. Acta, 181, 865, 10.1007/s00604-014-1181-1 · DOI · Paper page
- Mistry, 2014, A review on amperometric-type immunosensors based on screen-printed electrodes, Analyst, 139, 2289, 10.1039/c3an02050a · DOI
- Couto, 2016, Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis, Talanta, 146, 801, 10.1016/j.talanta.2015.06.011 · DOI · Paper page
- Suprun, 2011, Electrochemical immunosensor based on metal nanoparticles for cardiac myoglobin detection in human blood plasma, Electroanalysis, 23, 1051, 10.1002/elan.201000668 · doi:10.1002/elan.201000668
- Tam, 2011, Conducting polymer film-based immunosensors using carbon nanotube/antibodies doped polypyrrole, Appl. Surf. Sci., 257, 9817, 10.1016/j.apsusc.2011.06.028 · DOI
- Wang, 2018, Label-free electrochemical immunosensor based on flower-like Ag/MoS2/rGO nanocomposites for ultrasensitive detection of carcinoembryonic antigen, Sens. Actuators B Chem., 255, 125, 10.1016/j.snb.2017.07.129 · DOI · Paper page
- Mo, 2019, A sensitive and regenerative electrochemical immunosensor for quantitative detection of Escherichia coli O157: H7 based on stable polyaniline coated screen-printed carbon electrode and rGO-NR-Au@ Pt, Anal. Methods, 11, 1475, 10.1039/C8AY02594K · doi:10.1039/c8ay02594k
- Yukird, 2017, Label-free immunosensor based on graphene/polyaniline nanocomposite for neutrophil gelatinase-associated lipocalin detection, Biosens. Bioelectron., 87, 249, 10.1016/j.bios.2016.08.062 · DOI
- Bora, 2012, Fabrication of polypyrrole/graphene oxide nanocomposites by liquid/liquid interfacial polymerization and evaluation of their optical, electrical and electrochemical properties, Polymer, 53, 923, 10.1016/j.polymer.2011.12.054 · DOI · Paper page
- Xing, 2012, Electrochemical sensor based on molecularly imprinted film at polypyrrole-sulfonated graphene/hyaluronic acid-multiwalled carbon nanotubes modified electrode for determination of tryptamine, Biosens. Bioelectron., 31, 277, 10.1016/j.bios.2011.10.032 · DOI · Paper page
- 2016, Layered composites of PEDOT/PSS/nanoparticles and PEDOT/PSS/phthalocyanines as electron mediators for sensors and biosensors, Beilstein J. Nanotechnol., 7, 1948, 10.3762/bjnano.7.186 · doi:10.3762/bjnano.7.186
- Sharma, 2017, Electrochemical immunosensor based on poly (3,4-ethylenedioxythiophene) modified with gold nanoparticle to detect aflatoxin B1, Mater. Sci. Eng. C, 76, 802, 10.1016/j.msec.2017.03.146 · DOI
- Dhand, 2011, Recent advances in polyaniline based biosensors, Biosens. Bioelectron., 26, 2811, 10.1016/j.bios.2010.10.017 · DOI · Paper page
- Dey, 2012, Mediator free highly sensitive polyaniline–gold hybrid nanocomposite based immunosensor for prostate-specific antigen (PSA) detection, J. Mater. Chem., 22, 14763, 10.1039/c2jm31663c · DOI
- Hu, 2003, A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon, Talanta, 61, 769, 10.1016/S0039-9140(03)00368-0 · doi:10.1016/s0039-9140(03)00368-0
- Shaikh, 2019, Electrochemical immunosensor utilizing electrodeposited Au nanocrystals and dielectrophoretically trapped PS/Ag/ab-HSA nanoprobes for detection of microalbuminuria at point of care, Biosens. Bioelectron., 126, 572, 10.1016/j.bios.2018.11.035 · doi:10.1016/j.bios.2018.11.035
- Chuang, 2016, A rapid and sensitive impedance-based immunosensor utilizing dielectrophoretic manipulations of polyaniline modified nanoprobes, IEEE Sens. J., 16, 4166, 10.1109/JSEN.2016.2546954 · doi:10.1109/jsen.2016.2546954
- Tolba, 2012, A bacteriophage endolysin-based electrochemical impedance biosensor for the rapid detection of Listeria cells, Analyst, 137, 5749, 10.1039/c2an35988j · doi:10.1039/c2an35988j
- Ganesh, 2006, Self-assembled monolayers (SAMs) of alkoxycyanobiphenyl thiols on gold—A study of electron transfer reaction using cyclic voltammetry and electrochemical impedance spectroscopy, J. Colloid Interface Sci., 296, 195, 10.1016/j.jcis.2005.08.051 · doi:10.1016/j.jcis.2005.08.051
Cited by
Brett, C. M. A. (2022) · Molecules · doi:10.3390/molecules27051497 · Cited by 288
Yan, T., Zhang, G., Chai, H., Qu, L., & Zhang, X. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.753692 · Cited by 59
Metadata
- Authors
- Shaikh, M. O., Srikanth, B., Zhu, P.-Y., & Chuang, C.-H.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-09-16
- Volume
- 19
- Issue
- 18
- Pages
- 3990
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2972478211
- Cited by
- 50
- References
- 1
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- Ministry of Science and Technology, Taiwan (MOST 107-2221-E-218 -030 -MY3)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease. https://app.cochat.ai/papers/10.3390/s19183990
- The paper
- Shaikh, M. O., Srikanth, B., Zhu, P.-Y., & Chuang, C.-H. (2019). Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease. Sensors. https://doi.org/10.3390/s19183990
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.