The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects
Open accessAbstract
During recent years, field-effect transistor biosensors (Bio-FET) for biomedical applications have experienced a robust development with evolutions in FET characteristics as well as modification of bio-receptor structures. This review initially provides contemplation on this progress by analyzing and summarizing remarkable studies on two aforementioned aspects. The former includes fabricating unprecedented nanostructures and employing novel materials for FET transducers whereas the latter primarily synthesizes compact molecules as bio-probes (antibody fragments and aptamers). Afterwards, a future perspective on research of FET-biosensors is also predicted depending on current situations as well as its great demand in clinical trials of disease diagnosis. From these points of view, FET-biosensors with infinite advantages are expected to continuously advance as one of the most promising tools for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
Georgakilas, V., Perman, J. A., Tucek, J., & Zboril, R. (2015) · Chemical Reviews · doi:10.1021/cr500304f · Cited by 2,147
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Jang, H.-J., Lee, T., Song, J., Russell, L., Li, H., Dailey, J., Searson, P. C., & Katz, H. E. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18855 · Cited by 80
Cited by
Biosensing based on field-effect transistors (FET): Recent progress and challenges
Sadighbayan, D., Hasanzadeh, M., & Ghafar-Zadeh, E. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116067 · Cited by 305
Fazio, E., Spadaro, S., Corsaro, C., Neri, G., Leonardi, S. G., Neri, F., Lavanya, N., Sekar, C., Donato, N., & Neri, G. (2021) · Sensors · doi:10.3390/s21072494 · Cited by 274
Metadata
- Authors
- Vu, C.-A., & Chen, W.-Y.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-09-28
- Volume
- 19
- Issue
- 19
- Pages
- 4214
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2976050857
- Cited by
- 238
- References
- 6
- FWCI
- 13.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects. https://app.cochat.ai/papers/10.3390/s19194214
- The paper
- Vu, C.-A., & Chen, W.-Y. (2019). Field-Effect Transistor Biosensors for Biomedical Applications: Recent Advances and Future Prospects. Sensors. https://doi.org/10.3390/s19194214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.