Cited by 80Analytical Chemistry and SensorsElectrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting Materials

Electronic Cortisol Detection Using an Antibody-Embedded Polymer Coupled to a Field-Effect Transistor

Open access
Jang, Hyun-June, Lee, Taein, Song, Jian, Russell, Luisa, Li, Hui, Dailey, Jennifer, Searson, Peter C., Katz, Howard E.·2018·ACS Applied Materials & Interfaces

Abstract

A field-effect transistor-based cortisol sensor was demonstrated in physiological conditions. An antibody-embedded polymer on the remote gate was proposed to overcome the Debye length issue (λ D ). The sensing membrane was made by linking poly(styrene- co -methacrylic acid) (PSMA) with anticortisol before coating the modified polymer on the remote gate. The embedded receptor in the polymer showed sensitivity from 10 fg/mL to 10 ng/mL for cortisol and a limit of detection (LOD) of 1 pg/mL in 1× PBS where λ D is 0.2 nm. A LOD of 1 ng/mL was shown in lightly buffered artificial sweat. Finally, a sandwich ELISA confirmed the antibody binding activity of antibody-embedded PSMA.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.7b18855

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jang, H.-J., Lee, T., Song, J., Russell, L., Li, H., Dailey, J., Searson, P. C., & Katz, H. E.
Affiliations
Johns Hopkins University (US)
Corresponding author
Katz, Howard E.
Venue
ACS Applied Materials & Interfaces
Published
2018-04-27
Volume
10
Issue
19
Pages
16233-16237
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2799650283
Cited by
80
References
27
Citations by year
2026: 3 · 2025: 8 · 2024: 9 · 2023: 11 · 2022: 14 · 2021: 19 · 2020: 11 · 2019: 4 · 2018: 1
FWCI
5.27
Type
journal article
Language
en
Open access
Locations
  • ACS Applied Materials & Interfaces (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Air Force Research Laboratory
  • National Institute of Biomedical Imaging and Bioengineering (R21EB018426)
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
cortisol detection, field-effect transistor biosensors, poly(styrene-co-methacrylic acid), Debye length, artificial sweat, electrochemical biosensor, sandwich ELISA
MeSH terms
Equipment Design, Hydrocortisone, Polymers, Transistors, Electronic, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review