A Power Spectral Density-Based Method to Detect Tremor and Tremor Intermittency in Movement Disorders
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
There is no objective gold standard to detect tremors. This concerns not only the choice of the algorithm and sensors, but methods are often designed to detect tremors in one specific group of patients during the performance of a specific task. Therefore, the aim of this study is twofold. First, an objective quantitative method to detect tremor windows (TWs) in accelerometer and electromyography recordings is introduced. Second, the tremor stability index (TSI) is determined to indicate the advantage of detecting TWs prior to analysis. Ten Parkinson’s disease (PD) patients, ten essential tremor (ET) patients, and ten healthy controls (HC) performed a resting, postural and movement task. Data was split into 3-s windows, and the power spectral density was calculated for each window. The relative power around the peak frequency with respect to the power in the tremor band was used to classify the windows as either tremor or non-tremor. The method yielded a specificity of 96.45%, sensitivity of 84.84%, and accuracy of 90.80% of tremor detection. During tremors, significant differences were found between groups in all three parameters. The results suggest that the introduced method could be used to determine under which conditions and to which extent undiagnosed patients exhibit tremors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The total PSD in ET is higher than for controls [68], suggesting that, when performing similar tasks, people with ET have increased overall motor activity.”
From Wearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor (2024) · cites this paper as [68]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“While tremor frequency tends to be a little greater in physiological tremor, there is substantial overlap with ET frequencies24.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Previous research has shown the effectiveness of power spectral analysis of acceleration signal is effective in the detection of tremor24,39–41.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [24]
In the citing paper
“Power spectrum analysis of accelerometer signals can discriminate effectively between PD and controls, between ET and controls, and between PD and ET24.”
From Wearable sensors during drawing tasks to measure the severity of essential tremor (2022) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The assessment and analysis of handedness: The Edinburgh inventory
Oldfield, R. C. (1971) · Neuropsychologia · doi:10.1016/0028-3932(71)90067-4 · Cited by 35,900 · cited 1×
“All subjects were right-handed according to the Edinburgh Handedness Inventory [19], and all patients were off tremor-suppressing medication (tapered on an individual basis).”
MethodDiagnostic Criteria for Parkinson Disease
Gelb, D. J., Oliver, E., & Gilman, S. (1999) · Archives of Neurology · doi:10.1001/archneur.56.1.33 · Cited by 2,822 · cited 1×
“Furthermore, PD patients were diagnosed according to the UK Brain Bank criteria for Parkinson’s disease [20] and showed neither major fluctuation in symptoms nor suffer from severe dyskinesia.”
BackgroundConsensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“A large tremor frequency range needs to be adopted [16,17].”
BackgroundBhatia, K. P., Bain, P., Bajaj, N., Elble, R. J., Hallett, M., Louis, E. D., Raethjen, J., Stamelou, M., Testa, C. M., Deuschl, G., et al. (2018) · Movement Disorders · doi:10.1002/mds.27121 · Cited by 1,575 · cited 1×
“A large tremor frequency range needs to be adopted [16,17].”
BackgroundAccuracy of clinical diagnosis of Parkinson disease: A systematic review and meta-analysis
Rizzo, G., Copetti, M., Arcuti, S., Martino, D., Fontana, A., & Logroscino, G. (2016) · Neurology · doi:10.1212/wnl.0000000000002350 · Cited by 870
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Common Misdiagnosis of a Common Neurological Disorder: How Are We Misdiagnosing Essential Tremor?
Jain, S., Lo, S. E., & Louis, E. D. (2006) · Archives of Neurology · doi:10.1001/archneur.63.8.1100 · Cited by 304
Cohen, O., Pullman, S., Jurewicz, E., Watner, D., & Louis, E. D. (2003) · Archives of Neurology · doi:10.1001/archneur.60.3.405 · Cited by 298
Post, B., Merkus, M. P., de Bie, R. M. A., de Haan, R. J., & Speelman, J. D. (2005) · Movement Disorders · doi:10.1002/mds.20640 · Cited by 266
Characteristics of physiologic tremor in young and elderly adults
Elble, R. J. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00006-3 · Cited by 163 · cited 1×
“This is in accordance with a study of Elble [26], who found that up to 8% of young and elderly adults have an EMG-acceleration pattern which is indistinguishable from an essential tremor.”
Result
Cited by
Powers, R., Etezadi-Amoli, M., Arnold, E. M., Kianian, S., Mance, I., Gibiansky, M., Trietsch, D., Alvarado, A. S., Kretlow, J. D., Herrington, T. M., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abd7865 · Cited by 200
Machine Learning in Tremor Analysis: Critique and Directions
De, A., Bhatia, K. P., Volkmann, J., Peach, R. L., & Schreglmann, S. R. (2023) · Movement Disorders · doi:10.1002/mds.29376 · Cited by 47
“However, absolute mean TSI values for ET postural tremor have been reported below 0.5 by other groups, 15,16 casting doubt on its generalizability.”
BackgroundInfluentialWearable sensors during drawing tasks to measure the severity of essential tremor
Ali, S. M., Arjunan, S. P., Peters, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-08922-6 · Cited by 35
Spiral drawing analysis with a smart ink pen to identify Parkinson's disease fine motor deficits
Toffoli, S., Lunardini, F., Parati, M., Gallotta, M., MARIA, B. D., Longoni, L., Dell'Anna, M. E., & Ferrante, S. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1093690 · Cited by 24
“(38) in postural activities, was adapted to the spiral drawing condition (TSI_T) to measure the frequency variability in tremor cycles.”
MethodWearable Accelerometer and Gyroscope Sensors for Estimating the Severity of Essential Tremor
Ali, S. M., Arjunan, S. P., Peter, J., Perju-Dumbrava, L., Ding, C., Eller, M., Raghav, S., Kempster, P., Motin, M. A., Radcliffe, P. J., et al. (2024) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2023.3329344 · Cited by 22
“The total PSD in ET is higher than for controls [68], suggesting that, when performing similar tasks, people with ET have increased overall motor activity.”
BackgroundDevelopment of a New Wearable Device for the Characterization of Hand Tremor
Vescio, B., Maria, M. D., Crasà, M., Nisticò, R., Calomino, C., Aracri, F., Quattrone, A., & Quattrone, A. (2023) · Bioengineering · doi:10.3390/bioengineering10091025 · Cited by 19
Gauthier-Lafrenière, E., Aljassar, M., Rymar, V. V., MILTON, J. G., & Sadikot, A. F. (2022) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2022.878279 · Cited by 22
Crowe, C., Sica, M., Kenny, L., O’Flynn, B., Mueller, D. S., Timmons, S., Barton, J. J., & Tedesco, S. A. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3477003 · Cited by 19
“…ML and kinematics-based algorithms on inertial sensor data can indeed identify the three cardinal symptoms of PD: tremor [36], [39], [40], [41], [42], [43], [44], [45], bradykinesia [36], [39], [44], [45], [46], [47], [48], [49], [50], [51], [52], and dyskinesia [45], [50], [51], [52], [53],…”
BackgroundWearable Peripheral Electrical Stimulation Devices for the Reduction of Essential Tremor: A Review
Karamesinis, A. D., Sillitoe, R. V., & Kouzani, A. Z. (2021) · IEEE Access · doi:10.1109/access.2021.3084819 · Cited by 14
“measurements are being developed and validated [9]–[11].”
Defining the Rhythm: Developing a New Method to Describe Tremor and Myoclonus
Latorre, A., Hale, B., Cordivari, C., Humaidan, K., Rothwell, J. C., Bhatia, K. P., & Rocchi, L. (2025) · Movement Disorders · doi:10.1002/mds.70034 · Cited by 9
“8,9 One such feature, peak width (also termed full width at half maximum — FWHM — and half-power bandwidth in previous literature 4,10 ), re fl ects the range of frequencies contributing to the tremor signal and it has been proposed to distinguish ET from ET-plus and DT. 11,12 A broader peak width…”
Valdunciel, A. P., Lopo-Martínez, V., Beltrán-Carrero, A. J., Sendra-Arranz, R., González-Sánchez, M., Sánchez, J. R. P., Grandas, F., Farina, D., Pons, J. L., Barroso, F. O., et al. (2023) · Entropy · doi:10.3390/e25010114 · Cited by 12
Digranes, N., Hoeberg, E., Lervik, A., Hubin, A., Nordgreen, J., & Haga, H. A. (2024) · Veterinary Anaesthesia and Analgesia · doi:10.1016/j.vaa.2024.07.002 · Cited by 4
Phenotypical Differentiation of Tremor Using Time Series Feature Extraction and Machine Learning
Häring, V., Selzam, V., Martin‐Rodríguez, J. F., Schwingenschuh, P., Tamás, G., Köhler, L., Raethjen, J., Paschen, S., Goltz, F., Mulroy, E., et al. (2025) · Movement Disorders · doi:10.1002/mds.70032 · Cited by 6
“28 However, absolute TSI values have been found to differ in other cohorts, 29,30 casting doubt on its generalizability.”
Quantitative and qualitative tremor evaluation after MR-guided focused ultrasound thalamotomy
Purrer, V., Chand, T., Pohl, E., Weiland, H., Borger, V., Schmeel, F. C., Boecker, H., & Wüllner, U. (2025) · Frontiers in Neurology · doi:10.3389/fneur.2025.1594382 · Cited by 5
McGeown, J. P., Pedersen, M., Hume, P. A., Theadom, A., Kara, S., & Russell, B. K. (2023) · Biomechanics · doi:10.3390/biomechanics3020020 · Cited by 5
Sriraam, N. (2021) · International Journal of E-Health and Medical Communications · doi:10.4018/ijehmc.20211101.oa10 · Cited by 6
Shanghavi, A. A., Larrañaga, D., Patil, R., Frazier, E. M., Ambike, S., Duerstock, B. S., & Sereno, A. B. (2024) · Scientific Reports · doi:10.1038/s41598-024-60286-1 · Cited by 3
“For example, using accelerometer and electromyograph recordings of short 3-s windows in ET and PD patients, Luft and colleagues observed excellent classifier ( ∼ 91% accuracy) in categorizing short 3-s time windows as either tremor or non-tremor 28 .”
Action tremor kinematics exhibit features of stabilization dysfunction in essential tremor patients
Mendlen, M., Tien, R. N., Chee, K., Platt, J. P., Machnik, J. V., Bayman, E., Anigbogu, C., Kern, D. S., Ojemann, S. G., Thompson, J. A., et al. (2026) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2026.110680 · Cited by 1
Tiwari, V. K., Hossain, N. I., & Tabassum, S. (2023) · IEEE Dallas Circuits and Systems Conference (DCAS) · doi:10.1109/dcas57389.2023.10130272 · Cited by 1
“Using a support vector machine-based classification algorithm, Ghassemi et al. [11] obtained an overall accuracy of 83% by extracting and processing hand motion acceleration and EMG signals from standardized upper limb movements (resting, holding, and carrying weight) of 13 PD patients and 11…”
MethodLuft, F. (2020) · doi:10.3990/1.9789036549752
Self-citationDefining the rhythm: a new method to classify tremor and myoclonusPreprint
Latorre, A., Hale, B., Cordivari, C., Humaidan, K., Rothwell, J. C., Bhatia, K. P., & Rocchi, L. (2025) · medRxiv · doi:10.1101/2025.04.13.25325747
Accelerometer-Based Multi-Domain Feature Extraction for Parkinsonian Activity Recognition
Nguyen, H. T. A., Dao, V. A., Pham, Q. H., Nguyen, D. K., Pham, Q. N., & Le, N. T. (2025) · International Conference on Activity and Behavior Computing (ABC) · doi:10.1109/abc64332.2025.11118560
Sensor-based data-driven differentiation between Parkinson’s tremor and essential tremor
Sil, T., Selzam, V., Peach, R. L., Tamás, G., Deuschl, G., Schreglmann, S. R., Volkmann, J., Reich, M. M., & Muthuraman, M. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.130336 · Cited by 2
“Contradictory findings by other researchers raise robustness concerns (Balachandar et al., 2022; Luft et al., 2019; Panyakaew et al., 2020).”
Evolution and trends in tremor diagnosis and differential diagnosis—a bibliometric study
Liu, J., Xu, X., Liu, J., Bian, R., Zheng, J., Dong, K., Zhu, X., & Xh, C. (2026) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2026.1829580
“Building on this, Luft et al. (2019) introduced the concept of tremor windows (TWs) and employed 3D accelerometry combined with surface EMG to differentiate TWs from non-TW tremors (NTWs).”
Piazzalunga, C., Gentile, C., Dui, L. G., Donati, A., Ravazzani, S., Fontolan, S., Termine, C., & Ferrante, S. (2026) · Pattern Recognition Letters · doi:10.1016/j.patrec.2026.10.002
Quantification of Neuromotor Control in STXBP1 -Related Disorders With Wearable Sensors
Orlando, J. M., Bane, B., Chisari, T., Magielski, J. H., Pierce, S. R., Cunningham, K. G., Woo, C., Tefft, S., Nolan, J., Ruggiero, S. M., et al. (2026) · Neurology Genetics · doi:10.1212/nxg.0000000000200439 · Cited by 1
“While this range encompasses most pediatric limb movements and tremor frequencies, 34 and neurologic tremor rarely exceeds 10 Hz, 20 higher frequency components (greater than the Nyquist frequency of 10 Hz) could not be accurately evaluated and, therefore, may have been underestimated.”
Metadata
- Authors
- Luft, F., Sharifi, S., Mugge, W., Schouten, A., Bour, L., van Rootselaar, A.-F., Veltink, P., & Heida, T.
- Affiliations
- University of Twente (NL)
- Amsterdam Neuroscience (NL)
- Delft University of Technology (NL)
- Amsterdam Neuroscience, Amsterdam UMC, Department of Neurology, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands
- Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands
- Corresponding author
- Luft, Frauke
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-10-04
- Volume
- 19
- Issue
- 19
- Pages
- 4301
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC6806079
- OpenAlex
- W2977295017
- Cited by
- 27
- References
- 28
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 3 · 2023: 8 · 2022: 2 · 2021: 3 · 2020: 1
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Pure Amsterdam UMC (submittedVersion, cc-by)
- University of Twente Research Information (submittedVersion, cc-by)
- Research Repository (Delft University of Technology) (submittedVersion, cc-by)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- Stichting voor de Technische Wetenschappen (NeuroSIPE Project 10739)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- tremor detection, power spectral density, Parkinson's disease, essential tremor, movement disorders, electromyography, postural tremor, motor tasks
- MeSH terms
- Aged, Electromyography, Female, Humans, Male, Middle Aged, Movement, Parkinson Disease, Essential Tremor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.