Multi-Channel Neural Recording Implants: A Review
Open accessThe DOI matches its Crossref record; 123 of the 124 references it cites were found in a registry or an index.
Abstract
The recently growing progress in neuroscience research and relevant achievements, as well as advancements in the fabrication process, have increased the demand for neural interfacing systems. Brain–machine interfaces (BMIs) have been revealed to be a promising method for the diagnosis and treatment of neurological disorders and the restoration of sensory and motor function. Neural recording implants, as a part of BMI, are capable of capturing brain signals, and amplifying, digitizing, and transferring them outside of the body with a transmitter. The main challenges of designing such implants are minimizing power consumption and the silicon area. In this paper, multi-channel neural recording implants are surveyed. After presenting various neural-signal features, we investigate main available neural recording circuit and system architectures. The fundamental blocks of available architectures, such as neural amplifiers, analog to digital converters (ADCs) and compression blocks, are explored. We cover the various topologies of neural amplifiers, provide a comparison, and probe their design challenges. To achieve a relatively high SNR at the output of the neural amplifier, noise reduction techniques are discussed. Also, to transfer neural signals outside of the body, they are digitized using data converters, then in most cases, the data compression is applied to mitigate power consumption. We present the various dedicated ADC structures, as well as an overview of main data compression methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures














Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Biopotential amplifier designs use ac-coupled or dc-coupled structures for dc offset cancellation to avoid amplifier saturation due to the presence of electrode-tissue interface potentials [155], [158].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [155]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candes, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,839 · cited 1×
“As presented in [102], employing a random measurement matrix Φ , as a universal encoder as well as large enough input samples X is required to perform signal reconstruction of any sparse signal.”
MethodThe origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225 · cited 1×
“Noninvasive methods are capable of recording millions of neurons through the skull, however this signal is nonspecific and distorted [9,10].”
MethodNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 1×
“For example, researchers have implemented robotic limbs [1,2], speech synthesizers [3], and human neuroprosthetic control of computer cursors [4–6], utilizing less than 300 electrodes [7].”
MethodReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“For example, researchers have implemented robotic limbs [1,2], speech synthesizers [3], and human neuroprosthetic control of computer cursors [4–6], utilizing less than 300 electrodes [7].”
MethodSparsity and incoherence in compressive sampling
Candès, E., & Romberg, J. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/3/008 · Cited by 2,075 · cited 1×
“In this method, instead of sending all N samples of the neural signal of each channel, an M linear combination of these samples are sent where M is less than N [31–33].”
MethodEnz, C. C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,877 · cited 2×
“The residual output offset is mainly due to the non-idealities of the CMOS switches in the input chopper [73].”
BackgroundMethodLarge-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Research works printed but not linked: 8
- Clark, J.W., Neuman, M.R., Olson, W.H., Peura, R., Primiano, F., Siedband, M., Webster, J., and Wheeler, L. (1998). Medical Instrumentation: Application and Design, John Wiley & Sons.
- Kandel, E.R., Schwartz, J.H., Jessell, T.M., of Biochemistry, D., Jessell, M.B.T., Siegelbaum, S., and Hudspeth, A. (2000). Principles of Neural Science, McGraw-Hill.
- Abdelhalim, K., and Genov, R. (2012, January 20–23). Compact chopper-stabilized neural amplifier with low-distortion high-pass filter in 013 μm CMOS. Proceeding of the IEEE International Symposium on Circuits and Systems, Seoul, Korea.
- Carusone, T.C., Johns, D.A., and Martin, K.W. (2012). Integrated-Circuit Devices and Modeling. Analog Integrated Circuit Design, John Wiley & Sons. [2nd ed.].
- Razavi, B. (2005). Design of Analog CMOS Integrated Circuits, McGraw-Hill Series.
- Makinwa, K. (2007). Dynamic-offset Cancellation Techniques in CMOS. IEEE ISSCC Tutor. Sess.
- Van Der Meer, J.C., Riedijk, F.R., van Kampen, E., Makinwa, K.A., and Huijsing, J.H. (2005, January 10). A fully integrated CMOS Hall sensor with a 365 μT 3σ offset for compass applications. Proceedings of the IEEE International Solid State Circuits Conference—Digest of Technical Papers, San Francisco, CA, USA.
- Huang, Q., and Menolfi, C. (2001, January 7). A 200 nV offset 65 nV/Hz noise PSD 5.6 kHz chopper instrumentation amplifier in 1 μm digital CMOS. Proceedings of the IEEE International Solid-State Circuits Conference—Digest of Technical Papers, San Francisco, CA, USA.
Cited by
A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants
Yang, W., Gong, Y. P., & Li, W. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.622923 · Cited by 120
Applications of Microwaves in Medicine
Chiao, J. ‐., Li, C., Lin, J., Caverly, R. H., Hwang, J. C. M., Rosen, H. D., & Rosen, A. (2022) · IEEE Journal of Microwaves · doi:10.1109/jmw.2022.3223301 · Cited by 103
“Advances in amplifiers, noise reduction, analog-to-digital converters, and data compression techniques specific to neural signals [54] have increased the channel and electrode counts”
BackgroundSoft Electronics Based on Stretchable and Conductive Nanocomposites for Biomedical Applications
Zambrano, B. L., Renz, A. F., Ruff, T., Lienemann, S., Tybrandt, K., Vörös, J., & Lee, J. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202001397 · Cited by 76
Wu, H., Chen, J., Liu, X., Zou, W., Yang, J., & Sawan, M. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3293492 · Cited by 45
“signal [10], [11], [12], [13], [14], in which the amplitudes of most biosignals range from several μV to tens of mV, and frequencies in the sub-Hz to a few kHz, as illustrated in Table I.”
Self-citationCurrent and emerging strategies for biocompatible materials for implantable electronics
Zhou, Y., Morris, G. H. B., & Nair, M. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101852 · Cited by 51
Harnessing insect olfactory neural circuits for detecting and discriminating human cancers
Farnum, A., Parnas, M., Apu, E. H., Cox, E., Lefevre, N., Contag, C. H., & Saha, D. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114814 · Cited by 41
Recent Trends and Future Prospects of Neural Recording Circuits and Systems: A Tutorial Brief
Chen, J., Tarkhan, M., Wu, H., Noshahr, F. H., Yang, J., & Sawan, M. (2022) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2022.3171689 · Cited by 38
“Most bio-signals are sparse in the Gabor, time, or wavelet domains [11], making them applicable to compressive sensing.”
BackgroundSelf-citationRecording Strategies for High Channel Count, Densely Spaced Microelectrode Arrays
Pérez-Prieto, N., & Delgado‐Restituto, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.681085 · Cited by 25
Emerging Trends of Biomedical Circuits and Systems
Sawan, M., Yang, J., Tarkhan, M., Chen, J., Wang, M., Wang, C., Xia, F., & Chen, Y.-H. (2021) · Foundations and Trends® in Integrated Circuits and Systems · doi:10.1561/3500000005 · Cited by 23
Self-citationAbuShawish, I. Y., & Mahmoud, S. A. (2021) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2021.153952 · Cited by 21
Efficient in Vivo Neural Signal Compression Using an Autoencoder-Based Neural Network
Valencia, D., Mercier, P. P., & Alimohammad, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3359994 · Cited by 19
“Conventional analog front-end (AFE) circuitry for neural recording typically employs a shared ADC among various recording sites along with low-noise amplifiers (LNAs) [53].”
BackgroundHigh-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Tasneem, N. T., & Mahbub, I. (2021) · Electronics · doi:10.3390/electronics10050590 · Cited by 19
“Hence, the objective of this simultaneous multi-channel neuropotential recording system is to meet the constraints of low power, low noise, and minimized chip area to perceive brain signal insights [16,27].”
BackgroundMethodPalomeque-Mangut, D., Rodriguez-Vazquez, A., & Delgado‐Restituto, M. (2022) · Sensors · doi:10.3390/s22176429 · Cited by 12
“In most cases, neural stimulation uses current mode techniques to force a flow of charge through the extracellular fluid of some excitable nervous system tissue accessed with microelectrodes [5,6].”
BackgroundActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“Schematics of neural recording analog front-ends implemented using ( a ) an ac-coupled capacitive feedback network [155], ( b ) a dc-coupled amplifier with active low-frequency suppression [159], ( c ) a dc-coupled fully differential difference amplifier [170], and ( d ) a chopper-stabilised…”
Wireless interfaces for brain neurotechnologies
Kim, H., & Ho, J. S. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0020 · Cited by 18
“This system is implemented by an integrated circuit, which amplifies, filters, and digitizes signals with the goal of consuming the least possible amount of power [83,84].”
BackgroundMethodCMOS Bio-medical Amplifier based on Tera-Ohm Pseudo-resistor for Bio-detection System
AbuShawish, I. Y., & Mahmoud, S. A. (2021) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd52085.2021.9429430 · Cited by 11
“The issue is arising since these offset voltages which range between (1 mV – 50 mV) have higher voltages values compared to the brain’s signals, thus it is compulsory to get rid of these offset voltages [5].”
BackgroundA Compact Low-Power Chopper Low Noise Amplifier for High Density Neural Front-Ends
Fava, A., Centurelli, F., Monsurrò, P., & Scotti, G. (2025) · Sensors · doi:10.3390/s25041157 · Cited by 10
Koleibi, E. R., Lemaire, W., Koua, K., Benhouria, M., Bostani, R., Mazandarani, M. S., Gauthier, L.-P., Besrour, M., Ménard, J., Majdoub, M., et al. (2025) · Sensors · doi:10.3390/s25072320 · Cited by 11
Low-Cutoff Frequency Reduction in Neural Amplifiers: Analysis and Implementation in CMOS 65 nm
Noshahr, F. H., Nabavi, M., Gosselin, B. J., & Sawan, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667846 · Cited by 10
“A complete review on neural recording is given in Hashemi Noshahr et al. (2020) and Luan et al. (2020).”
BackgroundSelf-citationTechnical survey of end-to-end signal processing in BCIs using invasive MEAs
Erbslöh, A., Buron, L., Ur-Rehman, Z., Musall, S., Hrycak, C., Löhler, P., Klaes, C., Seidl, K., & Schiele, G. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8031 · Cited by 14
Constant Tera-ohm Pseudo-resistor Over Wide Dynamic Range
AbuShawish, I. Y., & Mahmoud, S. A. (2021) · IEEE International IOT, Electronics and Mechatronics Conference (IEMTRONICS) · doi:10.1109/iemtronics52119.2021.9422490 · Cited by 9
“The neural recording implants are the core element in the BMIs which consist of three main blocks, bio-medical amplifiers, ADCs and compressors [15], [16].”
BackgroundWu, H., Liu, X., Yang, J., & Sawan, M. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948655 · Cited by 9
Self-citationMoosaei, A., Maghami, M. H., Nejati, A., Amiri, P., & Sawan, M. (2025) · Electronics · doi:10.3390/electronics14081543 · Cited by 8
Self-citationAnalysing and measuring the performance of memristive integrating amplifiers
Wang, J., Serb, A., Papavassiliou, C., Maheshwari, S., & Prodromakis, T. (2021) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3101 · Cited by 8
“After processing, analogue neuronal trains [5] or digital format [6] will be transmitted to external devices wirelessly.”
MethodDrakopoulou, S., Varkevisser, F., Sohail, L., Aqamolaei, M., Costa, T. L., & Spyropoulos, G. D. (2023) · Frontiers in Electronics · doi:10.3389/felec.2023.1250655 · Cited by 10
“A pipeline ADC could be a good option if high-speed acquisition is the priority.”
BackgroundInfluentialJurgielewicz, P., Fiutowski, T., Kublik, E., Skoczeń, A., Szypulska, M., Wiacek, P. K., Hottowy, P., & Mindur, B. A. (2021) · Sensors · doi:10.3390/s21134423 · Cited by 8
“However, these electrodes are passive elements, and their development has to be followed/paralleled by the development of adequate electronic devices, able to amplify and filter electric signals from all MEAs’ sites simultaneously [13,14].”
BackgroundKim, H., Park, Y.-H., Eom, K., & Park, S. (2021) · Electronics · doi:10.3390/electronics10161972 · Cited by 9
Review on Variable and Programmable Gain Amplifiers and Applications
de Deus, M. S., Catunda, S. Y. C., Soares, A. W. A., & Belfort, D. R. (2022) · Journal of Integrated Circuits and Systems · doi:10.29292/jics.v17i1.583 · Cited by 12
“The signals acquired from these methods have a frequency range of a few mHz to 10 kHz and their amplitude is at the range of 20 μV to 10 mV [106].”
MethodChen, C., Yang, J., Sands, J., Khan, M. A., & Poon, A. S. Y. (2022) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2022.3202738 · Cited by 7
“Multiple review papers and tutorials have detailed these general considerations and their recent development [20], [21], [22].”
BackgroundMiniaturized Wireless Neural Interfaces: A tutorial
Muller, R., Ghanbari, M. M., & Zhou, A. (2021) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2021.3111387 · Cited by 6
“The design of recording circuits to manage the power and data demands of scale have been the subject of numerous review articles and tutorials [15]–[17].”
BackgroundBiomedical Amplifiers Design Based on Pseudo-Resistors: A Review
AbuShawish, I. Y., Mahmoud, S. A., Majzoub, S., & Hussain, A. J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3280668 · Cited by 6
“Having a high fL is desirable in some cases to detect the intra-cellular and extracellular APs which are in the range of (100 Hz–10 kHz) [5].”
BackgroundInfluentialDesign and Analysis of Cross-Coupled Source Degenerated Balanced OTA for Biomedical Application
Nath, S., Kundu, L., Guha, K., & Baishnab, K. L. (2024) · International Symposium on VLSI Design and Test (VDAT) · doi:10.1109/vdat63601.2024.10705720 · Cited by 5
“This proposed OTA in this paper is basically designed to be used in G m − C filter for recording neural extracellular action potential signal of band width 100Hz to 10kHz with an amplitude of 50 µV to 500 µV [14].”
MethodChen, Y., Yang, X., Gielen, G. E., & López, C. M. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3574917 · Cited by 5
“Additionally, this work does not seek to review or compare different recording architectures and their power/area trade-offs, as these aspects are covered in other dedicated studies [30], [31], [32].”
Abdelgaliel, B. H., Exalto, M., Ou-Yang, Y.-H., & Muratore, D. G. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798201 · Cited by 4
Shen, J., Li, M., Long, C., Yang, L., & Jiang, J. (2022) · Journal of Alzheimer s Disease · doi:10.3233/jad-220694 · Cited by 4
Liang, Z., Li, B., Wu, Z., & Hu, Y. (2020) · IEICE Electronics Express · doi:10.1587/elex.17.20200238 · Cited by 4
“The ripplereduction-loop (RRL) is also designed to suppress the output ripple, which is not introduced in this letter [29, 30, 31].”
BackgroundAn Intracortical Wireless Bidirectional Brain-Computer Interface with High Data Density
Kong, L., Zhang, Z., Yu, S. P., & Mao, J. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558134 · Cited by 3
“For the maximum number of occurrences of the APs, 120 per second [21], the system can still record 8 channels with a transmission rate of 460.8 kbps.”
BackgroundInfluentialHong, S. M., Park, J.-W., Jeong, J.-H., & Kim, S. Y. (2026) · Applied Sciences · doi:10.3390/app16041675 · Cited by 3
A 16-channel Si probe monolithically integrated with CMOS chips for neural recording
Gou, G., You, C., Yao, P., Guo, Y.-S., Liu, T.-Z., Song, Z., He, B.-Y., Yin, M., Zhang, X., Liu, C., et al. (2024) · Sensors and Actuators Reports · doi:10.1016/j.snr.2024.100206 · Cited by 3
AC amplifiers with ultra‐low corner frequency by using bootstrapping
Martincorena‐Arraiza, M., Carlosena, A., Cruz‐Blas, C. A. D. L., & López‐Martín, A. J. (2021) · Electronics Letters · doi:10.1049/ell2.12042 · Cited by 3
Digitally Programmable Gain and Tunable Band-Width DPOTA based Bio-medical Amplifier
AbuShawish, I. Y., & Mahmoud, S. A. (2021) · International SoC Design Conference · doi:10.1109/isocc53507.2021.9613859 · Cited by 3
Chen, J., Wu, H., Liu, X., Eskandari, R., Tian, F., Zou, W., Fang, C., Yang, J., & Sawan, M. (2023) · IEEE International Conference on Artificial Intelligence Circuits and Systems (AICAS) · doi:10.1109/aicas57966.2023.10168619 · Cited by 3
Self-citationA Two Channels Fully-Programmable Integrated Neurostimulator with a 0.07% Charge Mismatch
Contardi, S., Ria, A., Nannipieri, I., Scognamiglio, M., & Piotto, M. (2024) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime61930.2024.10559689 · Cited by 2
“To mitigate the effects of these disorders, NeuroStimulation (NS) has been used for at least two centuries as an alternative to classical treatments [1], [2].”
MethodTrzpil-Jurgielewicz, B., Dąbrowski, W., & Hottowy, P. (2021) · Sensors · doi:10.3390/s21093116 · Cited by 2
“Many designs based on this circuit idea, with excellent noise performance and low power consumption, have been reported; for a review see [29,30].”
BackgroundA Clockless Robust Bionic Spike Detector for Implantable Brain-Computer Interfaces
Chen, J., Liu, X., Wu, H., Tian, F., Zou, W., Katebi, M., Eskandari, R., Yang, J., & Sawan, M. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388732 · Cited by 2
Self-citationA Bidirectional ASIC for Active Microchannel Neural Interfaces
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2022) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs202256217.2022.9970803 · Cited by 2
“Several techniques for low-noise amplifier (LNA) design have been developed to filter out-of-band noise sources and limit in-band sources such as the 1/f noise to limit contribution to the inputreferred noise (IRN) and the noise efficiency factor (NEF), which highlights the noise-power trade-off [11].”
BackgroundTowards Task-aware Signal Compression for Efficient Continuous Health Monitoring
Wu, D., Yang, J., & Sawan, M. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937415 · Cited by 2
“It is a proven, resource-efficient, and low computation compression method that has been utilized in many implantable and wearable sensors [11], [12].”
Self-citationBrain-machine interface: New challenge for humanity
Nikolić, N., Bojić, L., & Tucaković, L. (2022) · Filozofija i drustvo · doi:10.2298/fid2202283n · Cited by 1
New Sensory Method for Neural Activity by Frequency Upconversion With Nonlinear Element
Bontempi, A., Meimandi, A., Barbruni, G. L., Crovetti, P., Demarchi, D., Carrara, S., & Ros, P. M. (2024) · IEEE Sensors Letters · doi:10.1109/lsens.2024.3430493 · Cited by 1
Mneimneh, M., Quadir, N. A., & Albasha, L. (2024) · IEEE Access · doi:10.1109/access.2024.3441840 · Cited by 1
“Most neural technologies are integrated using 180 nm technology or less posing significant challenges to reaching the required gain (gm) [82], [83].”
BackgroundMethodInfluentialEvaluation of surface roughness of titanium implants on human fibroblast cells
Hamadani, M. A., Banu, A., Wieczorek, K., Seneci, C., Irzan, H., García-Peraza-Herrera, L. C., Garna, D. F., Terry, S. Y. A., Silvio, L. D., Jha, P., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-46836-9 · Cited by 1
“These devices, ranging from cardiac pacemakers ensuring steady heart rhythms to neural implants that restore lost functionalities, have introduced transformative changes to healthcare practice 16–20 .”
Nicolini, G., Fava, A., Centurelli, F., & Scotti, G. (2024) · Journal of Low Power Electronics and Applications · doi:10.3390/jlpea14030038 · Cited by 1
“It is worth noting that down-scaling the technology to achieve a smaller area introduces short-channel effects of the MOS transistors, resulting in a reduction in transconductance and an increase in gate leakage current, flicker, and thermal noise power [27].”
BackgroundInvasive neurointerfaces – fields of their application.
Витальевна, Б. Е., Moscow, R., Shaderkina, A. I., Efimochkina, S. M., Litavrin, A. I., & Kuznetsova, M. A. (2024) · Russian Journal of Telemedicine and E-Health · doi:10.29188/2712-9217-2024-10-2-27-42 · Cited by 2
Programable Bandwidth Bio-medical Amplifier for Multiple Bio-potential Signals Detection Systems
AbuShawish, I. Y., & Mahmoud, S. A. (2021) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas47672.2021.9531898 · Cited by 1
Zhang, H., Wang, Y., Yang, X., Yuan, M., Yang, X., Gui, Q., Wang, Y., Chen, H., Liu, R., & Pei, W. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.11.07.515530 · Cited by 2
Low-Power Biopotential Signal Acquisition System for Biomedical Applications
Tasneem, N. T. (2022) · University of North Texas Digital Library (University of North Texas) · doi:10.12794/metadc1944354 · Cited by 1
Women in Circuits [Guest Editorial]
Gu, Q. J. (2022) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2022.3207334
Nonlinear Modeling and Precision Analysis of Neural Recording System in Simulink
He, J., Wang, Y., & Xu, J. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798142
Lin, X., Wang, B., Liu, L., Zhou, X., Yang, W., & Wang, H. (2025) · Circuits Systems and Signal Processing · doi:10.1007/s00034-025-03268-6
He, J., Xu, J., & Wang, Y. (2025) · Micromachines · doi:10.3390/mi16101176
“Neural recording system, a key component of BMIs, enables the acquisition of neural signals from different brain regions to decode brain functionality [9,10].”
Surface Engineering of Neural Implants
Rasulov, A., Yaxshinorov, H., Abdisattorov, J., Berdimurodov, E. T., Dagdag, O., Rbaa, M., Mamanazarov, M., & Berdimuradov, K. (2025) · Royal Society of Chemistry eBooks · doi:10.1039/9781837676606-00320
A Miniaturized 35uW Wirelessly Powered Chip for Implantable Neural Recording
Habibagahi, I., Mathews, R. P., Sharemi, H. J., & Babakhani, A. (2025) · IEEE BioSensors Conference (BioSensors) · doi:10.1109/biosensors65002.2025.11239335
Battery-Free Cmos Multichannel Selector Design for Electrical Stimulation and Recording
Banerjee, A., Benbuk, A. A., Gulick, D. W., & Christen, J. B. (2025) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas53549.2025.11244525
Design and Development of a Multi-stage High Gain EEG Amplifier for Neonatal Brain Signal Monitoring
Deepika, P., & Chandrasekaran, R. (2026) · Information systems engineering and management · doi:10.1007/978-3-032-20735-7_27
Dedhia, K., Airun, A., & Misra, M. (2026) · Springer eBooks · doi:10.1007/978-981-95-9386-6_13
Metadata
- Authors
- Hashemi Noshahr, F., Nabavi, M., & Sawan, M.
- Affiliations
- Polystim Neurotech. Lab., Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3T 1J4, Canada
- Polytechnique Montréal (CA)
- Westlake University (CN)
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-02-07
- Volume
- 20
- Issue
- 3
- Pages
- 904
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7038972
- OpenAlex
- W3004729186
- Cited by
- 66
- References
- 124
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 13 · 2023: 6 · 2022: 16 · 2021: 16 · 2020: 3
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- PolyPublie (École Polytechnique de Montréal) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- brain-computer interface, multichannel neural recording, neural amplifier, analog-to-digital converter, data compression, energy consumption reduction, noise reduction, neural signal processing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.