Review of Microwaves Techniques for Breast Cancer Detection
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Conventional breast cancer detection techniques including X-ray mammography, magnetic resonance imaging, and ultrasound scanning suffer from shortcomings such as excessive cost, harmful radiation, and inconveniences to the patients. These challenges motivated researchers to investigate alternative methods including the use of microwaves. This article focuses on reviewing the background of microwave techniques for breast tumour detection. In particular, this study reviews the recent advancements in active microwave imaging, namely microwave tomography and radar-based techniques. The main objective of this paper is to provide researchers and physicians with an overview of the principles, techniques, and fundamental challenges associated with microwave imaging for breast cancer detection. Furthermore, this study aims to shed light on the fact that until today, there are very few commercially available and cost-effective microwave-based systems for breast cancer imaging or detection. This conclusion is not intended to imply the inefficacy of microwaves for breast cancer detection, but rather to encourage a healthy debate on why a commercially available system has yet to be made available despite almost 30 years of intensive research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries
de González, A. B., & Darby, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15433-0 · Cited by 1,718
The benefits and harms of breast cancer screening: an independent review
(2012) · The Lancet · doi:10.1016/s0140-6736(12)61611-0 · Cited by 1,492
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439 · cited 1×
“The most common clinical imaging and detection modalities used for breast cancer detection are: X-ray mammography, magnetic resonance imaging (MRI), and ultrasound scanning [2].”
MethodLazebnik, M., Popovic, D., McCartney, L., Watkins, C. B., Lindstrom, M. J., Harter, J. M., Sewall, S., Ogilvie, T., Magliocco, A. M., Breslin, T. M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/20/002 · Cited by 1,402
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
Joines, W. T., Zhang, Y., Li, C., & Jirtle, R. L. (1994) · Medical Physics · doi:10.1118/1.597312 · Cited by 763 · cited 3×
“[17] 50–900 MHz Flat-ended coaxial probe Normal (unspecified) and malignant 12”
BackgroundMR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Orel, S. G., & Schnall, M. D. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl3113 · Cited by 759 · cited 1×
“Additionally, in MRI, inadequate breast positioning can cause unsuccessful detection [9].”
BackgroundDielectric properties of breast carcinoma and the surrounding tissues
Surowiec, A. J., Stuchly, S. S., Barr, J. R., & Swarup, A. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1374 · Cited by 736 · cited 2×
“[15] 20 kHz–100 MHz End-of-the-line capacitive probe Normal (various) and malignant 7”
BackgroundEnhancing breast tumor detection with near-field imaging
Fear, E. C., Hagness, S. C., Meaney, P. M., Okoniewski, M., & Stuchly, M. A. (2002) · IEEE Microwave Magazine · doi:10.1109/6668.990683 · Cited by 672
Microwave Imaging for Breast Cancer
Nikolova, N. (2011) · IEEE Microwave Magazine · doi:10.1109/mmm.2011.942702 · Cited by 640 · cited 2×
“Microwave-based detection modalities are mainly based on the observation of a high variation of the dielectric properties between normal and malignant breast tissues [12,13].”
BackgroundMethodHagness, S. C., Taflove, A., & Bridges, J. E. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.730440 · Cited by 637 · cited 2×
“[72] 6 GHz 17 3D-FDTD-CMI 2 mm NA PopoviC et al.”
BackgroundMicrowaves for breast cancer detection?
Fear, E. C., Meaney, P. M., & Stuchly, M. A. (2003) · IEEE Potentials · doi:10.1109/mp.2003.1180933 · Cited by 487
Lim, H. B., Nhung, N. T., Li, E., & Thang, N. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919716 · Cited by 468
Li, X., Bond, E., Veen, B. D. V., & Hagness, S. C. (2005) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2005.1436217 · Cited by 438 · cited 1×
“[141] 6 GHz M 2D-FDTD-MIST 2 mm DAS and AR Sill et al.”
MethodLi, X., Davis, S. K., Hagness, S. C., vanderWeide, D. W., & VanVeen, B. D. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832686 · Cited by 387 · cited 1×
“[135] 6 GHz 49 3D-FDTD-MIST 4 mm AR Nilavalan et al.”
MethodRadiation and breast cancer: a review of current evidence
Ronckers, C. M., Erdmann, C. A., & Land, C. E. (2004) · Breast Cancer Research · doi:10.1186/bcr970 · Cited by 366
Hagness, S. C., Taflove, A., & Bridges, J. E. (1999) · IEEE Transactions on Antennas and Propagation · doi:10.1109/8.774131 · Cited by 358
Microwave Breast Imaging: Clinical Advances and Remaining Challenges
O’Loughlin, D., O’Halloran, M., Moloney, B. M., Glavin, M., Jones, E., & Elahi, M. A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2809541 · Cited by 307 · cited 1×
“This can have a significant impact on the measured data, apart from the effects of sample temperatures, patients’ age, and time taken between the measurements and excision of the samples [20,24,30].”
BackgroundElectromagnetic Breast Imaging: Results of a Pilot Study in Women with Abnormal Mammograms
Poplack, S. P., Tosteson, T. D., Wells, W. A., Pogue, B. W., Meaney, P. M., Hartov, A., Kogel, C. A., Soho, S. K., Gibson, J. J., & Paulsen, K. D. (2007) · Radiology · doi:10.1148/radiol.2432060286 · Cited by 299
Dielectric Properties Characterization From 0.5 to 50 GHz of Breast Cancer Tissues
Martellosio, A., Bellomi, M., Pasian, M., Bozzi, M., Perregrini, L., Mazzanti, A., Svelto, F., Summers, P. E., Renne, G., & Preda, L. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2631162 · Cited by 261
Microwave tomography: review of the progress towards clinical applications
Semenov, S. Y. (2009) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2009.0092 · Cited by 224
Recent Advances in Microwave Imaging for Breast Cancer Detection
Kwon, S., & Lee, S. (2016) · International Journal of Biomedical Imaging · doi:10.1155/2016/5054912 · Cited by 219 · cited 2×
“An MI system is based on two main parts: (i) hardware (antenna) responsible for illuminating and collecting microwave signals reflected from the illuminated object under test such as breast tissues; (ii) software or post-processing algorithms that are responsible for reconstructing an image of the target object as sho…”
BackgroundMethodA Wearable Microwave Antenna Array for Time-Domain Breast Tumor Screening
Porter, E., Bahrami, H., Santorelli, A., Gosselin, B., Rusch, L. A., & Popovic, M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2518489 · Cited by 216 · cited 2×
“The results showed that the quality of reconstructed breast images was improved (see Figure 28) [83].”
BackgroundMARIA M4: clinical evaluation of a prototype ultrawideband radar scanner for breast cancer detection
Preece, A. W., Craddock, I. J., Shere, M., Jones, L. I., & Winton, H. L. (2016) · Journal of medical imaging · doi:10.1117/1.jmi.3.3.033502 · Cited by 207
An Early Clinical Study of Time-Domain Microwave Radar for Breast Health Monitoring
Porter, E., Coates, M., & Popovic, M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2465867 · Cited by 200 · cited 1×
“McGill University 5 min 13 ! 7 Microstrip stationary Time, DAS Seated [110] shell”
BackgroundComplex permittivities of breast tumor tissues obtained from cancer surgeries
Sugitani, T., Kubota, S.-I., Kuroki, S.-I., Sogo, K., Arihiro, K., Okada, M., Kadoya, T., Hide, M., Oda, M., & Kikkawa, T. (2014) · Applied Physics Letters · doi:10.1063/1.4885087 · Cited by 199
Dielectric properties of female human breast tissue measured in vitro at 3.2 GHz
Campbell, A. M., & Land, D. V. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/1/014 · Cited by 189
Shea, J. D., Kosmas, P., Van Veen, B. D., & Hagness, S. C. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/7/074009 · Cited by 158 · cited 1×
“[202] 3 GHz 40 3D-FDTD 10 mm and 20 mm GNIA”
Davis, S. K., Tandradinata, H., Hagness, S. C., & VanVeen, B. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847528 · Cited by 151
Hussein, M. I., Awwad, F. R., Jithin, D., Hasasna, H. E., Athamneh, K., & Iratni, R. (2019) · Scientific Reports · doi:10.1038/s41598-019-41124-1 · Cited by 143
Neira, L. M., Veen, B. D. V., & Hagness, S. C. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2751668 · Cited by 133
Microwave Imaging of the Breast
Fear, E. C. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400110 · Cited by 130 · cited 2×
“Bridges’ method utilized an ultra-wide microwave signal to illuminate the breast tissues using an antenna array placed at different locations surrounding the breast [73,74].”
BackgroundMethodCheng, Y., & Fu, M. (2018) · Thoracic Cancer · doi:10.1111/1759-7714.12605 · Cited by 128
Computational modeling of three-dimensional microwave tomography of breast cancer
Bulyshev, A., Semenov, S. Y., Souvorov, A. E., Svenson, R. H., Nazarov, A. G., Sizov, Y. E., & Tatsis, G. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.942596 · Cited by 127 · cited 1×
“The data visualization part is achieved by utilizing 2D or 3D tomogram images that show the presence, location, and size of the tumour [37,54].”
MethodPoplack, S. P., Paulsen, K. D., Hartov, A., Meaney, P. M., Pogue, B. W., Tosteson, T. D., Grove, M. R., Soho, S. K., & Wells, W. A. (2004) · Radiology · doi:10.1148/radiol.2312030606 · Cited by 126
Multiple-Frequency DBIM-TwIST Algorithm for Microwave Breast Imaging
Miao, Z., & Kosmas, P. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2679067 · Cited by 116
ON QUANTITATIVE MICROWAVE TOMOGRAPHY OF FEMALE BREAST
Catapano, I., Donato, L. D., Crocco, L., Bucci, O. M., Morabito, A. F., Isernia, T., & Massa, R. (2009) · Electromagnetic waves · doi:10.2528/pier09080604 · Cited by 111
Microwave open-ended coaxial dielectric probe: interpretation of the sensing volume re-visited
Meaney, P. M., Gregory, A. P., Epstein, N. R., & Paulsen, K. D. (2014) · BMC Medical Physics · doi:10.1186/1756-6649-14-3 · Cited by 109
Fang, Q., Meaney, P. M., & Paulsen, K. D. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832014 · Cited by 106
Estimating the Breast Surface Using UWB Microwave Monostatic Backscatter Measurements
Winters, D. W., Shea, J. D., Madsen, E. L., et al. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901028 · Cited by 105
Quasi-Multistatic MIST Beamforming for the Early Detection of Breast Cancer
O’Halloran, M., Jones, E., & Glavin, M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2016392 · Cited by 99
Time-Domain Wideband Adaptive Beamforming for Radar Breast Imaging
Byrne, D., & Craddock, I. J. (2015) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2015.2398125 · Cited by 95
A Multithreshold Iterative DBIM-Based Algorithm for the Imaging of Heterogeneous Breast Tissues
Ambrosanio, M., Kosmas, P., & Pascazio, V. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2849648 · Cited by 88 · cited 1×
“Furthermore, some of these methodologies adopted magnetic nanoparticles [87,88] and compressive sensing tools [97] to enhance the detection process,”
MethodDATA INDEPENDENT RADAR BEAMFORMING ALGORITHMS FOR BREAST CANCER DETECTION
Byrne, D., O’Halloran, M., Glavin, M., & Jones, E. (2010) · Electromagnetic waves · doi:10.2528/pier10061001 · Cited by 85
Machine Learning Approaches for Automated Lesion Detection in Microwave Breast Imaging Clinical Data
Rana, S. P., Dey, M., Tiberi, G., Sani, L., Vispa, A., Raspa, G., Duranti, M., Ghavami, M., & Dudley, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-46974-3 · Cited by 81
Davis, S. K., Bond, E., Hagness, S. C., & Veen, B. D. V. (2003) · Journal of Electromagnetic Waves and Applications · doi:10.1163/156939303322235860 · Cited by 80 · cited 1×
“[131] 6 GHz 17 2D-FDTD-MIST 2 mm SSA Zhang et al.”
MethodWavelet-Based Regularization for Robust Microwave Imaging in Medical Applications
Scapaticci, R., Kosmas, P., & Crocco, L. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2381270 · Cited by 77 · cited 1×
“[92] 1–3 GHz Distorted Born inversion method”
Two-dimensional computer analysis of a microwave flat antenna array for breast cancer tomography
Souvorov, A. E., Bulyshev, A., Semenov, S. Y., Svenson, R. H., & Tatsis, G. (2000) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.859490 · Cited by 73
Ultra wideband compact near‐field imaging system for breast cancer detection
Jalilvand, M., Li, X., Zwirełło, Ł., & Zwick, T. (2015) · IET Microwaves Antennas & Propagation · doi:10.1049/iet-map.2014.0735 · Cited by 66
An Effective Procedure for MNP-Enhanced Breast Cancer Microwave Imaging
Scapaticci, R., Bellizzi, G. G., Catapano, I., Crocco, L., & Bucci, O. M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2293839 · Cited by 63 · cited 1×
“[90] 2 GHz Magnetic nanoparticles as the contrast agent”
BackgroundLi, Y., Porter, E., Santorelli, A., Popović, M., & Coates, M. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.003 · Cited by 62 · cited 2×
“The presented classification techniques had the ability to distinguish between normal and malignant breast tissues [84].”
BackgroundA Time-Domain Microwave System for Breast Cancer Detection Using a Flexible Circuit Board
Santorelli, A., Porter, E., Kang, E., Piske, T., Popović, M., & Schwartz, J. D. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2440565 · Cited by 60 · cited 2×
“The system performance was clinically tested showcasing its capability for detecting a 1 cm tumour inserted inside a breast phantom (see Figure 26) [82].”
MethodInvestigation of Histology Region in Dielectric Measurements of Heterogeneous Tissues
Porter, E., & O’Halloran, M. (2017) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2017.2741026 · Cited by 52
Accuracy Evaluation of Ultrawideband Time Domain Systems for Microwave Imaging
Zeng, X., Fhager, A., Persson, M., Linnér, P., & Zirath, H. (2011) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2011.2164174 · Cited by 43
Application of the No-Sampling Linear Sampling Method to Breast Cancer Detection
Bozza, G., Brignone, M., & Pastorino, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055059 · Cited by 40
Effect of logarithmic and linear frequency scales on parametric modelling of tissue dielectric data
Salahuddin, S., Porter, E., Meaney, P. M., & O’Halloran, M. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa59db · Cited by 32 · cited 1×
“This can have a significant impact on the measured data, apart from the effects of sample temperatures, patients’ age, and time taken between the measurements and excision of the samples [20,24,30].”
BackgroundCo-polarised and cross-polarised antenna arrays for breast, cancer detection
Jafari, H. M., Deen, M. J., Hranilovic, S., & Nikolova, N. K. (2007) · IET Microwaves Antennas & Propagation · doi:10.1049/iet-map:20060327 · Cited by 32
Kwon, S., Lee, H., & Lee, S. (2016) · Electronics Letters · doi:10.1049/el.2015.3613 · Cited by 25
An Analysis of the Assumptions Inherent to Near-Field Beamforming for Biomedical Applications
Curtis, C. F., Lavoie, B. R., & Fear, E. C. (2017) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2017.2756022 · Cited by 22
Microwave Radar Imaging of Heterogeneous Breast Tissue Integrating A Priori Information
Moll, J., Kelly, T. N., Byrne, D., Sarafianou, M., Krozer, V., & Craddock, I. J. (2014) · International Journal of Biomedical Imaging · doi:10.1155/2014/943549 · Cited by 21 · cited 1×
“[239] 2 GHz 31 3D-FDTD 4 mm DAS Song et al.”
MethodEstimating average dielectric properties for microwave breast imaging using focal quality metrics
O’Loughlin, D., Krewer, F., Glavin, M., et al. (2016) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2016.7481766 · Cited by 15 · cited 1×
“[255] 6 GHz 20 3D-FDTD-CMI 3 mm and 5 mm DAS”
Medina, M. A. Y., Manuel, A., & Paz, A. V. (2016) · IEEE ANDESCON · doi:10.1109/andescon.2016.7836226 · Cited by 13 · cited 1×
“[257] 9 GHz 1 2D-FDTD-CMI 15 mm DAS Song et al.”
Cited by
Breast cancer heterogeneity and its implication in personalized precision therapy
Guo, L., Kong, D., Liu, J., Zhan, L., Luo, L., Zheng, W., Zheng, Q., Chen, C., & Sun, S. (2023) · Experimental Hematology & Oncology · doi:10.1186/s40164-022-00363-1 · Cited by 327
Metadata
- Authors
- Aldhaeebi, M. A., Alzoubi, K., Almoneef, T. S., Bamatraf, S. M., Attia, H., & Ramahi, O. M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-04-22
- Volume
- 20
- Issue
- 8
- Pages
- 2390
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3018270146
- Cited by
- 237
- References
- 61
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.