Pressure sensors have been widely used in electronic wearable devices and medical devices to detect tiny physical movements and mechanical deformation. However, it remains a challenge to fabricate desirable, comfortable wearing, and highly sensitive as well as fast responsive sensors to capture human body physiological signs. Here, a new capacitive flexible pressure sensor that is likely to solve this problem was constructed using thermoplastic polyurethane elastomer rubber (TPU) electrospinning nanofiber membranes as a stretchable substrate with the incorporation of silver nanowires (AgNWs) to build a composite dielectric layer. In addition, carbon nanotubes (CNTs) were painted on the TPU membranes as flexible electrodes by screen printing to maintain the flexibility and breathability of the sensors. The flexible pressure sensor could detect tiny body signs; fairly small physical presses and mechanical deformation based on the variation in capacitance due to the synergistic effects of microstructure and easily altered composite permittivity of AgNW/TPU composite dielectric layers. The resultant sensors exhibited high sensitivity (7.24 kPa−1 within the range of 9.0 × 10−3 ~ 0.98 kPa), low detection limit (9.24 Pa), and remarkable breathability as well as fast responsiveness (<55 ms). Moreover, both continuously pressing/releasing cycle over 1000 s and bending over 1000 times did not impair the sensitivity, stability, and durability of this flexible pressure sensor. This proposed strategy combining the elastomer nanofiber membrane and AgNW dopant demonstrates a cost-effective and scalable fabrication of capacitive pressure sensors as a promising application in electronic skins and wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inflammation-free, gas-permeable, lightweight, stretchable on-skin electronics with nanomeshes
Miyamoto, A., Lee, S., Cooray, N. F., Lee, S., Mori, M., Matsuhisa, N., Jin, H., Yoda, L., Yokota, T., Itoh, A., et al. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.125 · Cited by 1,181
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870 · cited 1×
“Currently, with the development of technology and the progress of society, more and more flexible and highly sensitive pressure sensors are being developed for various applications in health monitoring [14,15], human-machine interfaces [16,17], smart robots [18,19], wearable devices [20,21], etc.”
BackgroundCarbonized Silk Nanofiber Membrane for Transparent and Sensitive Electronic Skin
Wang, Q., Jian, M., Wang, C., & Zhang, Y. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605657 · Cited by 549
Jia, J., Huang, G., Deng, J., & Pan, K. (2019) · Nanoscale · doi:10.1039/c8nr08503j · Cited by 172 · cited 1×
“[32] managed to fabricate a capacitive pressure sensor by using rGO film as the dielectric layer to increase the permittivity, which not only achieved high sensitivity (178 kPa−1), but also acquired a low detection limit (42 Pa).”
Method
Cited by
A review on polymers and their composites for flexible electronics
Li, L., Han, L., Hu, H., & Zhang, R. (2023) · Materials Advances · doi:10.1039/d2ma00940d · Cited by 256
Yuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180
Sharma, A., Ansari, M. Z., & Cho, C. (2022) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2022.113934 · Cited by 95
Li, X., Liu, Y., Ding, Y., Zhang, M., Lin, Z., Hao, Y., Li, Y., & Chang, J. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c01042 · Cited by 79
Self-citation
Metadata
- Authors
- Wang, J., Lou, Y., Wang, B., Sun, Q., Zhou, M., & Li, X.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-04-26
- Volume
- 20
- Issue
- 9
- Pages
- 2459
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3018712997
- Cited by
- 83
- References
- 4
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive, Breathable, and Flexible Pressure Sensor Based on Electrospun Membrane with Assistance of AgNW/TPU as Composite Dielectric Layer. https://app.cochat.ai/papers/10.3390/s20092459
- The paper
- Wang, J., Lou, Y., Wang, B., Sun, Q., Zhou, M., & Li, X. (2020). Highly Sensitive, Breathable, and Flexible Pressure Sensor Based on Electrospun Membrane with Assistance of AgNW/TPU as Composite Dielectric Layer. Sensors. https://doi.org/10.3390/s20092459
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.