The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Evaluation of the Pose Tracking Performance of the Azure Kinect and Kinect v2 for Gait Analysis in Comparison with a Gold Standard: A Pilot Study
Open accessAbstract
Gait analysis is an important tool for the early detection of neurological diseases and for the assessment of risk of falling in elderly people. The availability of low-cost camera hardware on the market today and recent advances in Machine Learning enable a wide range of clinical and health-related applications, such as patient monitoring or exercise recognition at home. In this study, we evaluated the motion tracking performance of the latest generation of the Microsoft Kinect camera, Azure Kinect, compared to its predecessor Kinect v2 in terms of treadmill walking using a gold standard Vicon multi-camera motion capturing system and the 39 marker Plug-in Gait model. Five young and healthy subjects walked on a treadmill at three different velocities while data were recorded simultaneously with all three camera systems. An easy-to-administer camera calibration method developed here was used to spatially align the 3D skeleton data from both Kinect cameras and the Vicon system. With this calibration, the spatial agreement of joint positions between the two Kinect cameras and the reference system was evaluated. In addition, we compared the accuracy of certain spatio-temporal gait parameters, i.e., step length, step time, step width, and stride time calculated from the Kinect data, with the gold standard system. Our results showed that the improved hardware and the motion tracking algorithm of the Azure Kinect camera led to a significantly higher accuracy of the spatial gait parameters than the predecessor Kinect v2, while no significant differences were found between the temporal parameters. Furthermore, we explain in detail how this experimental setup could be used to continuously monitor the progress during gait rehabilitation in older people.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OpenPose: Realtime Multi-Person 2D Pose Estimation Using Part Affinity Fields
Cao, Z., Hidalgo, G., Simon, T., Wei, S.-E., & Sheikh, Y. (2021) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2019.2929257 · Cited by 5,536
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Real-time human pose recognition in parts from single depth images
Shotton, J., Fitzgibbon, A., Cook, M., Sharp, T., Finocchio, M., Moore, R., Kipman, A., & Blake, A. (2011) · CVPR 2011 · doi:10.1109/cvpr.2011.5995316 · Cited by 3,491
DeepPose: Human Pose Estimation via Deep Neural Networks
Toshev, A., & Szegedy, C. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.214 · Cited by 3,185
White Paper: “Walking Speed: the Sixth Vital Sign”
Fritz, S., & Lusardi, M. (2009) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200932020-00002 · Cited by 1,390
Zeni, J. A., Richards, J. G., & Higginson, J. S. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.07.007 · Cited by 1,261
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
VNect: real-time 3D human pose estimation with a single RGB camera
Mehta, D., Sridhar, S., Sotnychenko, O., Rhodin, H., Shafiei, M., Seidel, H.-P., Xu, W., Casas, D., & Theobalt, C. (2017) · ACM Transactions on Graphics · doi:10.1145/3072959.3073596 · Cited by 1,113
Validity of the Microsoft Kinect for assessment of postural control
Clark, R. A., Pua, Y.-H., Fortin, K., Ritchie, C., Webster, K. E., Denehy, L., & Bryant, A. L. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.033 · Cited by 687
Automatic detection of gait events using kinematic data
O’Connor, C. M., Thorpe, S. K., O’Malley, M. J., & Vaughan, C. L. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2006.05.016 · Cited by 557
Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease
Galna, B., Barry, G., Jackson, D., Mhiripiri, D., Olivier, P., & Rochester, L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.01.008 · Cited by 544
A Study of Vicon System Positioning Performance
Merriaux, P., Dupuis, Y., Boutteau, R., Vasseur, P., & Savatier, X. (2017) · Sensors · doi:10.3390/s17071591 · Cited by 435
Kinect range sensing: Structured-light versus Time-of-Flight Kinect
Sarbolandi, H., Lefloch, D., & Kolb, A. (2015) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2015.05.006 · Cited by 389
Quantitative Gait Analysis in Parkinson’s Disease: Comparison With a Healthy Control Group
Sofuwa, O., Nieuwboer, A., Desloovere, K., Willems, A.-M., Chavret, F., & Jonkers, I. (2005) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2004.08.012 · Cited by 351
Gait parameters following stroke: a practical assessment.
von Schroeder, H. P., Coutts, R. D., Lyden, P. D., Billings, E., & Nickel, V. L. (1995) · PubMed · Cited by 317
Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function
Otte, K., Kayser, B., Mansow-Model, S., Verrel, J., Paul, F., Brandt, A. U., & Schmitz-Hübsch, T. (2016) · PLOS ONE · doi:10.1371/journal.pone.0166532 · Cited by 255
Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking
Xu, X., McGorry, R. W., Chou, L.-S., Lin, J.-H., & Chang, C.-C. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.05.002 · Cited by 239
Lachat, E., Macher, H., Landes, T., & Grussenmeyer, P. (2015) · Remote Sensing · doi:10.3390/rs71013070 · Cited by 212
Clark, R. A., Mentiplay, B. F., Hough, E., & Pua, Y. H. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2018.11.029 · Cited by 209
Evaluation of Pose Tracking Accuracy in the First and Second Generations of Microsoft Kinect
Wang, Q., Kurillo, G., Ofli, F., & Bajcsy, R. (2015) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi.2015.54 · Cited by 199
Mentiplay, B. F., Perraton, L. G., Bower, K. J., Pua, Y.-H., McGaw, R., Heywood, S., & Clark, R. A. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.05.021 · Cited by 195
Geerse, D. J., Coolen, B. H., & Roerdink, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0139913 · Cited by 182
Improved kinect-based spatiotemporal and kinematic treadmill gait assessment
Eltoukhy, M. A., Oh, J., Kuenze, C. M., & Signorile, J. F. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.10.001 · Cited by 148
Constraints on the kinetic, kinematic and spatiotemporal parameters of gait in Parkinson's disease
Morris, M. E., McGinley, J. L., Huxham, F. E., Collier, J. M., & Iansek, R. (1999) · Human Movement Science · doi:10.1016/s0167-9457(99)00020-2 · Cited by 145
A markerless system for gait analysis based on OpenPose library
D’Antonio, E., Taborri, J., Palermo, E., Rossi, S., & Patanè, F. (2020) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc43012.2020.9128918 · Cited by 94
Fusion of depth, skeleton, and inertial data for human action recognition
Chen, C., Jafari, R., & Kehtarnavaz, N. (2016) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2016.7472170 · Cited by 90
Tsushima, H., Morris, M. E., & McGinley, J. L. (2003) · Journal of the Japanese Physical Therapy Association · doi:10.1298/jjpta.6.9 · Cited by 77
Accuracy evaluation of the Kinect v2 sensor during dynamic movements in a rehabilitation scenario
Capecci, M., Ceravolo, M. G., Ferracuti, F., Iarlori, S., Longhi, S., Romeo, L., Russi, S. N., & Verdini, F. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591950 · Cited by 55
Macpherson, T. W., Taylor, J. M., McBain, T., Weston, M., & Spears, I. R. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.008 · Cited by 38
Naeemabadi, M., Dinesen, B., Andersen, O. K., & Hansen, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204052 · Cited by 37
Lin, C., Chang, C.-L., Lu, M., Lu, T., & Wu, C. (2018) · BMC Veterinary Research · doi:10.1186/s12917-018-1714-7 · Cited by 21
Scano, A., Caimmi, M., Chiavenna, A., Malosio, M., & Tosatti, L. M. (2016) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-4666-9740-9.ch013 · Cited by 7
Metadata
- Authors
- Albert, J. A., Owolabi, V., Gebel, A., Brahms, C. M., Granacher, U., & Arnrich, B.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-09-08
- Volume
- 20
- Issue
- 18
- Pages
- 5104
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3083997743
- Cited by
- 261
- References
- 32
- FWCI
- 11.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.