Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
There is an increased interest in using wearable inertial measurement units (IMUs) in clinical contexts for the diagnosis and rehabilitation of gait pathologies. Despite this interest, there is a lack of research regarding optimal sensor placement when measuring joint kinematics and few studies which examine functionally relevant motions other than straight level walking. The goal of this clinical measurement research study was to investigate how the location of IMU sensors on the lower body impact the accuracy of IMU-based hip, knee, and ankle angular kinematics. IMUs were placed on 11 different locations on the body to measure lower limb joint angles in seven participants performing the timed-up-and-go (TUG) test. Angles were determined using different combinations of IMUs and the TUG was segmented into different functional movements. Mean bias and root mean square error values were computed using generalized estimating equations comparing IMU-derived angles to a reference optical motion capture system. Bias and RMSE values vary with the sensor position. This effect is partially dependent on the functional movement analyzed and the joint angle measured. However, certain combinations of sensors produce lower bias and RMSE more often than others. The data presented here can inform clinicians and researchers of placement of IMUs on the body that will produce lower error when measuring joint kinematics for multiple functionally relevant motions. Optimization of IMU-based kinematic measurements is important because of increased interest in the use of IMUs to inform diagnose and rehabilitation in clinical settings and at home.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Niswander et al., 2020
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172 · cited 1×
“While direct observation of human gait is easily done, the quantification of gait is more difficult but important to effectively track changes over time or compare gait to other clinical populations [2].”
BackgroundDeterminants of the Sit-to-Stand Movement: A Review
Janssen, W. G., Bussmann, H. B., & Stam, H. J. (2002) · Physical Therapy · doi:10.1093/ptj/82.9.866 · Cited by 692 · cited 1×
“Examining functional movements such as sit-to-stand and turning are important to clinicians because they aid in assessing lower extremity strength and balance [8,9].”
BackgroundInertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients
Rampp, A., Barth, J., Schuelein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2368211 · Cited by 303 · cited 1×
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
Spain, R. I., St. George, R. J., Salarian, A., Mancini, M., Wagner, J. M., Horak, F. B., & Bourdette, D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.026 · Cited by 287
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237
Gait posture estimation using wearable acceleration and gyro sensors
Takeda, R., Tadano, S., Natorigawa, A., Todoh, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.016 · Cited by 197 · cited 1×
“Other studies have reported lower RMSE values at the same joints [39,40].”
BackgroundPacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.08.025 · Cited by 188 · cited 4×
“A few publications optimized sensor placement when measuring gait parameters such as stance/swing percent and cadence [10,11] and evaluated sensitivity of pose estimation accuracy to IMU sensor placements during single leg squats [12].”
BackgroundInfluentialPalermo, E., Rossi, S., Marini, F., Patanè, F., & Cappa, P. (2014) · Measurement · doi:10.1016/j.measurement.2014.03.004 · Cited by 182 · cited 1×
“was used to define calibration vectors describing body segment orientations in terms of sensor coordinate systems and is briefly described here [18].”
MethodMeasurement of foot placement and its variability with inertial sensors
Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.05.012 · Cited by 180 · cited 1×
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
Clinimetric Properties of the Timed Up and Go Test for Patients With Stroke: A Systematic Review
Hafsteinsdóttir, T. B., Rensink, M., & Schuurmans, M. (2014) · Topics in Stroke Rehabilitation · doi:10.1310/tsr2103-197 · Cited by 176 · cited 1×
“Participants performed the Timed-Up-And-Go (TUG) test given its extensive validation in clinical populations and the variety of functional movements performed [13–15].”
Method
Cited by
Items 101–116 of 116
Vogl, A. M., Becker, L. K., Liebetanz, K., Zorn, J., Tsitou, P.-E., & Gulde, P. (2026) · Next research. · doi:10.1016/j.nexres.2026.102099
IMU-based gait analysis methods: a systematic review of techniques for different body locations
Chen, L., Guo, R., Guo, R., Chen, Y., Wang, Y., Zhang, S., & Zhang, Q. (2026) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2026.1854615
“Niswander et al. (9) systematically evaluated 11 anatomical locations during the timed-up-and-go test, revealing that standardized placements for straight-line walking are insufficient for complex clinical assessments.”
Moan, D. L., & Phomsoupha, M. (2026) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371261475045
IMU- and Vision-Based Measurement Techniques for Joint Kinematics: A Narrative Review
Ceriola, L., Molinaro, L., Taborri, J., Patanè, F., & Mileti, I. (2026) · Sensors · doi:10.3390/s26165063
“…the physical placement of IMUs also influences bias and RMSE; a dedicated sensor placement optimization study demonstrated that errors depend on sensor location and the movement sub-task being analyzed, highlighting a practical source of variability in clinical and field deployments [160].”
Saroli, V., Santis, R. D., Silvestri, S., Schena, E., & Massaroni, C. (2026) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot69397.2026.11653073
A Quantitative Comparison of Human Body Modeling Methods to Synthesize IMU Data
Uhlenberg, L., Kempfle, J., Haeusler, L. O., & Amft, O. (2026) · IEEE Access · doi:10.1109/access.2026.3726408
“To understand the impact of variations in sensor modalities and positions, whether for human activity recognition (HAR), biomedical prediction, or wearable health monitoring, iterative physical testing of sensor devices that involves human participants is essential [1], [2], [3].”
Rattanakoch, J., Limroongreungrat, W., Guerra, G., Manupibul, U., Apidech, H., Niamsang, W., Suphab, M., Laucha, T., & Samala, M. (2026) · PLoS ONE · doi:10.1371/journal.pone.0356786
“Sensor location has been shown to influence lower-limb joint-angle estimates [34], whereas sensor-to-segment misalignment can substantially affect estimates of knee abduction and internal rotation [35].”
Saroli, V., Lelli, M., Schena, E., & Massaroni, C. (2026) · Additive Manufacturing Letters · doi:10.1016/j.addlet.2026.100418 · Cited by 1
GyroStep: A Portable IMU-Based System for Knee Flexion Measurement and Real-Time Analysis
Korbel, J., Frącczak, Ł., & Piasecka, K. (2026) · International Conference on Methods and Models in Automation and Robotics · doi:10.1109/mmar70562.2026.11667872
Three-Axis Distance Estimation Using an Inertial Measurement Unit
Kongpramot, C., Auysakul, J., Stojanović, G., & Chatpun, S. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-29116-5_22
Validation of a Smartphone Imu Against Force Plate for Postural Sway Assessment
Shrestha, A., Ghahramani, M., & French, J. (2026) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc66907.2026.11694954
“The Umidigi Power 5 smartphone (dimensions: 164.0 × 74.9 × 16.9 mm; weight: 218 g; sampling frequency: 50 Hz; Android OS 11) was converted into a wearable device by securing it in a waist pack positioned at the L4-L5 lumbar region, approximating the body’s center of mass [20].”
InfluentialCarro, G. G., Álvarez, J. C. Á., Alonso, A. C., Prieto, D. Á., & Lopez, A. M. (2026) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc66907.2026.11694494
“Static-pose calibration techniques [22] report RMSEs spanning from 3.90° to over 6° across the lower-limb joints.”
InfluentialChien, Y.-H., Koo, L.-K., Chang, C.-W., Chen, C.-C., Chen, S., & Wang, F. (2026) · Sensors · doi:10.3390/s26196182
“According to the requirements of different functional tests, IMUs were secured to designated anatomical landmarks, adhering to previous research [23,30,46,47].”
Liu, W., Lu, C., & Qian, L. (2026) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2026.1980454
Molero-Mateo, P., Trigo, C., Torres-Pardo, A., Navarro‐López, V., Vázquez, D. F., Rueda, F. M., Diego, I. M. A., Carratalá‐Tejada, M., Algaba-Vidoy, M., Akgün, İ., et al. (2026) · Biosystems & biorobotics · doi:10.1007/978-3-032-18746-8_8
Lira-Zamacona, M. A., León-Hernández, A. D., López‐López, C. O., & Martínez‐Hernández, A. (2026) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk11040433
Metadata
- Authors
- Niswander, W., Wang, W., & Kontson, K.
- Affiliations
- United States Food and Drug Administration (US)
- Corresponding author
- Kontson, Kimberly
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-10-22
- Volume
- 20
- Issue
- 21
- Pages
- 5993
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7660215
- OpenAlex
- W3094382181
- Cited by
- 116
- References
- 39
- Citations by year
- 2026: 32 · 2025: 23 · 2024: 23 · 2023: 18 · 2022: 13 · 2021: 7
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Food and Drug Administration (CPI)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, sensor placement, lower limb joint kinematics, hip joint angle, knee joint angle, ankle joint angle, Timed Up and Go test, wearable sensors, gait analysis, measurement accuracy, functional movement, rehabilitation
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Biomechanical Phenomena, Exercise Test, Humans, Range of Motion, Articular, Walking, Lower Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.