Optimization of IMU Sensor Placement for the Measurement of Lower Limb Joint Kinematics
Open accessAbstract
There is an increased interest in using wearable inertial measurement units (IMUs) in clinical contexts for the diagnosis and rehabilitation of gait pathologies. Despite this interest, there is a lack of research regarding optimal sensor placement when measuring joint kinematics and few studies which examine functionally relevant motions other than straight level walking. The goal of this clinical measurement research study was to investigate how the location of IMU sensors on the lower body impact the accuracy of IMU-based hip, knee, and ankle angular kinematics. IMUs were placed on 11 different locations on the body to measure lower limb joint angles in seven participants performing the timed-up-and-go (TUG) test. Angles were determined using different combinations of IMUs and the TUG was segmented into different functional movements. Mean bias and root mean square error values were computed using generalized estimating equations comparing IMU-derived angles to a reference optical motion capture system. Bias and RMSE values vary with the sensor position. This effect is partially dependent on the functional movement analyzed and the joint angle measured. However, certain combinations of sensors produce lower bias and RMSE more often than others. The data presented here can inform clinicians and researchers of placement of IMUs on the body that will produce lower error when measuring joint kinematics for multiple functionally relevant motions. Optimization of IMU-based kinematic measurements is important because of increased interest in the use of IMUs to inform diagnose and rehabilitation in clinical settings and at home.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Niswander et al., 2020
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172 · cited 1×
“While direct observation of human gait is easily done, the quantification of gait is more difficult but important to effectively track changes over time or compare gait to other clinical populations [2].”
BackgroundDeterminants of the Sit-to-Stand Movement: A Review
Janssen, W. G., Bussmann, H. B., & Stam, H. J. (2002) · Physical Therapy · doi:10.1093/ptj/82.9.866 · Cited by 692 · cited 1×
“Examining functional movements such as sit-to-stand and turning are important to clinicians because they aid in assessing lower extremity strength and balance [8,9].”
BackgroundInertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients
Rampp, A., Barth, J., Schuelein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2368211 · Cited by 303 · cited 1×
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
Spain, R. I., St. George, R. J., Salarian, A., Mancini, M., Wagner, J. M., Horak, F. B., & Bourdette, D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.026 · Cited by 287
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237
Gait posture estimation using wearable acceleration and gyro sensors
Takeda, R., Tadano, S., Natorigawa, A., Todoh, M., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.016 · Cited by 197 · cited 1×
“Other studies have reported lower RMSE values at the same joints [39,40].”
BackgroundPacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.08.025 · Cited by 188 · cited 4×
“A few publications optimized sensor placement when measuring gait parameters such as stance/swing percent and cadence [10,11] and evaluated sensitivity of pose estimation accuracy to IMU sensor placements during single leg squats [12].”
BackgroundInfluentialPalermo, E., Rossi, S., Marini, F., Patanè, F., & Cappa, P. (2014) · Measurement · doi:10.1016/j.measurement.2014.03.004 · Cited by 182 · cited 1×
“was used to define calibration vectors describing body segment orientations in terms of sensor coordinate systems and is briefly described here [18].”
MethodMeasurement of foot placement and its variability with inertial sensors
Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.05.012 · Cited by 180 · cited 1×
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
Clinimetric Properties of the Timed Up and Go Test for Patients With Stroke: A Systematic Review
Hafsteinsdóttir, T. B., Rensink, M., & Schuurmans, M. (2014) · Topics in Stroke Rehabilitation · doi:10.1310/tsr2103-197 · Cited by 176 · cited 1×
“Participants performed the Timed-Up-And-Go (TUG) test given its extensive validation in clinical populations and the variety of functional movements performed [13–15].”
Method
Cited by
Cereatti, A., Gurchiek, R., Mündermann, A., Fantozzi, S., Horak, F., Delp, S., & Aminian, K. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112225 · Cited by 79
Tibial bone forces can be monitored using shoe-worn wearable sensors during running
Elstub, L. J., Nurse, C. A., Grohowski, L. M., Völgyesi, P., Wolf, D. N., & Zelik, K. E. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2107816 · Cited by 41
“However, the optimization of IMU calibration (Choe et al., 2019; Favre et al., 2008), placement (Niswander et al., 2020), and processing (Gui et al., 2015; Sabatelli et al., 2013) has led to improvements in accuracy of kinematic estimates compared with 3D motion capture during gait (Lebleu et al.,…”
MethodNiswander, W., & Kontson, K. L. (2021) · Sensors · doi:10.3390/s21123989 · Cited by 45
“Although other locations on the upper thigh and lower torso were identified as common locations for IMU sensors in previous work [23], Panebianco et al.”
MethodSelf-citationRattanakoch, J., Samala, M., Limroongreungrat, W., Guerra, G., Tharawadeepimuk, K., Nanbancha, A., Niamsang, W., Kerdsomnuek, P., & Suwanmana, S. (2023) · Sensors · doi:10.3390/s23031738 · Cited by 34
Co-simulation of human digital twins and wearable inertial sensors to analyse gait event estimation
Uhlenberg, L., Derungs, A., & Amft, O. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1104000 · Cited by 36
“Practical deployment of wearable motion analysis often involves iterative physical testing to optimise and correct sensor positioning (Förster et al., 2009; Niswander et al., 2020), which is tedious due to repeated measurements and prone to error due to, e.”
MethodIoT-Enabled Gait Assessment: The Next Step for Habitual Monitoring
Young, F., Mason, R., Morris, R., Stuart, S., & Godfrey, A. (2023) · Sensors · doi:10.3390/s23084100 · Cited by 39
“For example, Niswander et al. [63] found that the Top: use early PD to detect (i.e., hip, knee and ankle) requires 3.2.1.”
BackgroundInfluentialMarques, J. B., Auliffe, S. M., Thomson, A., Sideris, V., Santiago, P. R. P., & Read, P. J. (2022) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2022.01.004 · Cited by 27
Ainuddin, H. A., Romli, M. H., Hamid, T. A., Salim, M. S., & Mackenzie, L. A. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.611793 · Cited by 63
Validation of a portable marker-based motion analysis system
Wang, S., Zeng, X., Huangfu, L., Xie, Z., Ma, L., Huang, W., & Zhang, Y. (2021) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-021-02576-2 · Cited by 20
Robust Sensor Fusion and Biomimetic Control of a Lower-Limb Exoskeleton With Multimodal Sensors
Arceo, J. C., Yu, L., & Bai, S. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2024.3421318 · Cited by 19
“Subsequently, in [7] the ideal placement of IMU sensors for accurately measuring the hip, knee, and ankle joints was explored, recommending sensor placement at specific body locations and utilizing optical motion capture for sensor calibration.”
Jabri, S., Carender, W. J., Wiens, J., & Sienko, K. H. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01099-z · Cited by 20
“The choice of IMU placement on different body segments was shown to have an effect on model performance in the context of gait-based classification of stroke and other neurological disorders [36], and the choice of IMU placement on a given body segment was shown to affect the accuracy of estimated spatio-temporal gait…”
BackgroundMeng, W., Zhu, C. J., Liu, H., Liu, Q., & Xie, S. Q. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3385798 · Cited by 22
“Human-robot state information mainly includes kinematic information, kinetic information, and physiological information, which can be obtained from the pressure-sensitive insole, FSR [82], [83], [84], encoder, IMU [85], [86], load cell [87], [88], and EMG sensor [89], [90], [91], [92].”
BackgroundMethodInfluentialde Miguel-Fernández, J., Rio, M. S.-D., Rey-Prieto, M., Bayón, C., Guirao-Cano, L., Font-Llagunes, J. M., & Lobo-Prat, J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1208561 · Cited by 17
“However, it is important to consider that the accuracy of estimation is highly related to the level of impairment and the location of the IMU sensors (Picerno, 2017; Carcreff et al., 2018; Niswander et al., 2020).”
BackgroundDigo, E., Panero, E., Agostini, V., & Gastaldi, L. (2022) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119221135051 · Cited by 16
“The position is slightly above the calcaneum, as it was instead in Misu et al.30 and Niswander et al.31 IMUs on the trunk (TRN), right ankle (ANK_R), and left ankle (ANK_L) were oriented with the x-axis (xTRN, xANK_R, and xANK_L) pointing downward, the y-axis (yTRN, yANK_R, and yANK_L) directed toward the participant’…”
MethodBrognara, L., Mazzotti, A., Zielli, S. O., Arceri, A., Artioli, E., Traina, F., & Faldini, C. (2024) · Sensors · doi:10.3390/s24217059 · Cited by 24
“The positioning of sensors is crucial, as improper placement can result in unreliable data due to placement errors, and the effectiveness of the algorithms used can vary depending on the target cohort and environment [59–61].”
Moghadam, S. M., Yeung, T., & Choisne, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3317366 · Cited by 19
“The type of activity (such as sit-to-stand, stand-to-sit, turning, stair climbing, and walking) can also affect the optimal number and location of IMU sensors [20].”
BackgroundMethodPlaza-Bravo, J. M., Mateo‐March, M., Sanchís-Sanchís, R., Pérez‐Soriano, P., Zabala, M., & Martínez, A. E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19148375 · Cited by 16
“At present, this type of technology is widely used, and currently, this type of device is becoming more and more frequent in the analysis of different joint angles [7] applied to human gait [8], especially to analyze heel strike and toe off [9], in the running analysis [10,11], in weightlifting to measure barbell spee…”
BackgroundVilla, G., Cerfoglio, S., Bonfiglio, A., Capodaglio, P., Galli, M., & Cimolin, V. (2025) · Sensors · doi:10.3390/s25123736 · Cited by 14
“However, while IMU-based systems are generally reported to provide reliable descriptions, their accuracy in estimating joint kinematics can vary depending on system complexity and sensor placement [54,55].”
Ng, G., & Andrysek, J. (2023) · Sensors · doi:10.3390/s23031412 · Cited by 17
“This location was chosen based on previous work [12,34].”
MethodThe Effect of Sensor Feature Inputs on Joint Angle Prediction across Simple Movements
Hollinger, D. S., Schall, M. C., Chen, H., & Zabala, M. E. (2024) · Sensors · doi:10.3390/s24113657 · Cited by 13
“Along with sensor count and type, precise sensor location for extracting relevant physiological signals is essential for effective HMIP [19].”
MethodFezazi, M. E., Achmamad, A., Jbari, A., & Jilbab, A. (2023) · Scientific African · doi:10.1016/j.sciaf.2023.e01676 · Cited by 10
“Data collection The dataset used in this research was collected and used in [27].”
MethodZhang, Y., Liu, X., Qiao, X., & Fan, Y. (2022) · Machines · doi:10.3390/machines10111061 · Cited by 9
Quantifying Turning Tasks With Wearable Sensors: A Reliability Assessment
Weston, A. R., Antonellis, P., Fino, P. C., Hoppes, C. W., Lester, M., Weightman, M. M., Dibble, L. E., & King, L. A. (2023) · Physical Therapy · doi:10.1093/ptj/pzad134 · Cited by 10
González‐Alonso, J., Simón-Martínez, C., Antón‐Rodríguez, M., González‐Ortega, D., Pernas, F. J. D., & Martínez‐Zarzuela, M. (2024) · Safety Science · doi:10.1016/j.ssci.2024.106431 · Cited by 10
“Sensor placement is crucial in both upper-limb (H ¨ oglund et al., 2021) and lower-limb (Niswander et al., 2020) IMU-based approaches, since incorrect placement can lead to measurement inconsistencies.”
Cornish, B. M., Diamond, L. E., Saxby, D. J., Lloyd, D. G., Shi, B., Lyon, J., Abbruzzese, K. M., Gallie, P., & Maharaj, J. N. (2024) · PLoS ONE · doi:10.1371/journal.pone.0297899 · Cited by 8
“Inertial measurement units have measured joint angles during functional tasks with root-mean-square-difference (RMSD) less than 5 degrees compared to OMC [22, 28–30], which were not different to OMC for measurement of knee ROM during walking in individuals post total hip arthroplasty [31].”
MethodResultCeglia, A., Facon, K., Begon, M., & Séoud, L. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109434 · Cited by 7
“The first technology is based on inertial measurement units (IMUs) placed on predefined positions of body segments [NWK20].”
MethodNilsson, S., Ertzgaard, P., Lundgren, M., & Grip, H. (2022) · Sensors · doi:10.3390/s22031171 · Cited by 10
“This study suggested that the foot sensor could be placed either on the dorsal foot (as in our study) or on the heel, and that the shank sensor should be placed in a lateral position [33].”
MethodDang, M., Liu, B., Chen, Y., & Zhang, Z. (2026) · Psychoradiology · doi:10.1093/psyrad/kkag007 · Cited by 10
An Integrated Approach for Real-Time Monitoring of Knee Dynamics with IMUs and Multichannel EMG
Malešević, N., Svensson, I., Hägglund, G., & Antfolk, C. (2023) · Sensors · doi:10.3390/s23218955 · Cited by 9
“In the study by Niswander et al. [42], the RMSE was 6.35 ◦ during the timed-up-and-go task.”
MethodInfluentialThe Development of a Motion-Tracking System to Assess the Recovery Level for Stroke Survivors
Nguyen, T.-T., Nguyen, Q.-D., Ha, M.-Q., Hoang, X.-T., Bui, T. N., & Tien, D.-L. (2024) · Acta Polytechnica Hungarica · doi:10.12700/aph.21.9.2024.9.2 · Cited by 9
“The Kalman filter acts as a crucial component in enhancing the overall performance of the BNO055, especially in dynamic and challenging environments where accurate orientation data is paramount [27].”
BackgroundIoT-Based System Using IMU Sensor Fusion for Knee Telerehabilitation Monitoring
Fezazi, M. E., Achmamad, A., Jbari, A., & Jilbab, A. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3542261 · Cited by 7
“The proposed sensor fusion algorithm was compared with two commonly used algorithms, GDCF, and KF. Algorithms were executed on real hardware and were tested on a pre-recorded human motion dataset [31].”
Optimal placement of IMU sensor for the detection of children activity
Madej, M., & Rumiński, J. (2022) · Conference on Human System Interactions · doi:10.1109/hsi55341.2022.9869442 · Cited by 7
“physical activity pattern evaluation [13], tracking rehabilitation process [14] [15] , gait analysis [16] [17], supporting elderly in daily activities [18], sport science [19] or behavior analysis [20] [21].”
BackgroundSensAA—Design and Verification of a Cloud-Based Wearable Biomechanical Data Acquisition System
David, J. P., Schick, D., Rapp, L., Schick, J., & Glaser, M. (2024) · Sensors · doi:10.3390/s24082405 · Cited by 7
“This could help create an extensive database for human kinematics.”
BackgroundImproved Spatiotemporal Framework for Human Activity Recognition in Smart Environment
Salem, Z., & Weiss, A. P. (2022) · Sensors · doi:10.3390/s23010132 · Cited by 8
“This is emphasized for comparing reported prediction accuracies in different works [46].”
ResultPrelević, M., Dopsaj, M., & Stančin, S. (2023) · Sensors · doi:10.3390/s23031456 · Cited by 7
Jiménez-Olmedo, J. M., Tortosa‐Martínez, J., Cortell-Tormo, J. M., & Pueo, B. (2024) · Sensors · doi:10.3390/s24061903 · Cited by 8
“For hip flexion ROM in the leg position, the devices were affixed to the middle lateral thigh, equidistant between the hip and knee joints [19].”
MethodPurushothaman, M. B., & Gedara, K. M. (2023) · Smart and Sustainable Built Environment · doi:10.1108/sasbe-02-2023-0037 · Cited by 7
Between-site equivalence of turning speed assessments using inertial measurement units
Parrington, L., King, L. A., Weightman, M. M., Hoppes, C. W., Lester, M., Dibble, L. E., & Fino, P. C. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.09.164 · Cited by 6
Ankle Kinematics Estimation Using Artificial Neural Network and Multimodal IMU Data
Wang, L., Song, P., Stone, T., Weller, A., & Pattinson, S. W. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3514669 · Cited by 5
“Currently, there is no standard to place IMUs for optimal estimations of ankle kinematics, with common positions including dorsal foot, heel, and/or lateral shank [29].”
Hansson, E. E., Akar, Y., Liu, T., Wang, C., & Fänge, A. M. (2022) · BMC Research Notes · doi:10.1186/s13104-022-06196-9 · Cited by 7
“IMU:s is a practical and portable way of collecting this type of data [12] and can be used for analyzing a range of components of movements [13].”
MethodFeng, Y., Chen, X., Xing, Z., Li, Y., Liu, F., & Zhao, J. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3266454 · Cited by 6
“units [4], [5], [6], and wearable soft sensors [7], [8], [9], [10], [11].”
Moeller, T., Beyerlein, M., Herzog, M., Barisch‐Fritz, B., Marquardt, C., Dežman, M., Mombaur, K., Asfour, T., Wöll, A., Stein, T., et al. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ada333 · Cited by 7
“The information provided by IMUs can thus be beneficial not only for fall detection but also during functional balance tasks such as the TUG test [184].”
Liu, W., & Bai, J. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1372757 · Cited by 4
“The pelvis, thighs, shanks, and feet IMUs were equipped on the sacrum, lateral femur, lateral tibia and dorsal feet of the elderly individuals (Niswander et al., 2020; Rekant et al., 2022).”
Matsuda, T., Watanabe, J., Sotokawa, T., Shishime, T., & Katoh, H. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10030356 · Cited by 4
“For the inertial system, two sensors were attached: one to the spinous process of the third lumbar vertebra (L3) and the other to the lower lateral shank (LLS) of the right leg [39].”
Mihy, J. A., Wagatsuma, M., Cain, S. M., & Hafer, J. F. (2026) · Journal of Applied Biomechanics · doi:10.1123/jab.2025-0073 · Cited by 13
Exploring the potential of electrical bioimpedance technique for analyzing physical activity
Hafid, A., Zolfaghari, S., Kristoffersson, A., & Folke, M. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1515431 · Cited by 4
Squat Kinematics Analysis Using Vicon and Affordable Motion-Capture Solutions
Czajkowska, U., Popek, M., Pezowicz, C. A., Leśnik, B., & Żuk, M. (2025) · Sensors · doi:10.3390/s25113294 · Cited by 5
Fennel, M., Driller, L., Zea, A., & Hanebeck, U. D. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.171 · Cited by 4
Treadmill-to-Overground Mapping of Marker Trajectory for Treadmill-Based Continuous Gait Analysis
Jung, W. C., & Lee, J. K. (2021) · Sensors · doi:10.3390/s21030786 · Cited by 4
Samala, M., Rattanakoch, J., Guerra, G., Tharawadeepimuk, K., Nanbancha, A., Niamsang, W., Kerdsomnuek, P., Suwanmana, S., & Limroongreungrat, W. (2024) · Scientific Data · doi:10.1038/s41597-024-03677-3 · Cited by 7
“Hence, the MyoRESEARCH 3.18 software has integrated robust reliability techniques and suitable algorithms to mitigate probable sensor-related problems 41,42 .”
MethodInfluentialMacdermid, P. W., Walker, S. J., Ingalla, B., & Leuchanka, A. (2026) · Applied Sciences · doi:10.3390/app16020784 · Cited by 3
Bevrnja, M., Vučina, A., & Bajrić, H. (2024) · Lecture notes in networks and systems · doi:10.1007/978-3-031-66268-3_6 · Cited by 3
Real-Time Estimation of Lower Limb Posture and Joint Angles Using Wearable IMUs:
Kanega, S., & Muraoka, Y. (2025) · Japanese Journal of Comprehensive Rehabilitation Science · doi:10.11336/jjcrs.16.19 · Cited by 3
Razak, H. R. B. A., Chua, N., & Weng, L. K. (2025) · Sensors · doi:10.3390/s25134211 · Cited by 3
“As noted in Experiment A, near-pivot sensor placement contributed to the inaccuracies in knee rotation angle measurements observed in Experiment B [51,52,58].”
CNN-Based Intention Recognition Using Body-Worn Inertial Measurement Units
Bajraktari, F., Roβkopf, N., & Pott, P. P. (2023) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms58004.2023.00315 · Cited by 5
A Data-Driven Approach to Running Gait Assessment Using Inertial Measurement Units
Ross, E., Milian, A., Ferlic, M., Reed, S., & Lepley, A. S. (2022) · Video Journal of Sports Medicine · doi:10.1177/26350254221102464 · Cited by 3
“Video Journal of Sports Medicine (VJSM ), 2(5), 26350254221102464 DOI: 10.”
Limited Interchangeability of Smartwatches and Lace-Mounted IMUs for Running Gait Analysis
Meingast, T., Carrier, B., Melvin, A. C., Kozloff, K. M., Lempke, A. F. D., & Lepley, A. S. (2025) · Sensors · doi:10.3390/s25175553 · Cited by 3
“…difference in cadence estimation via wrist-based sensors which estimates step frequency based on arm movement, as opposed to a two-pod sensor system that directly measures step-by-step movements at the feet, as biomechanical estimations have been found to vary with IMU sensor placements [40].”
Xu, C. F., Tan, Y. H., Strout, Z., Liu, G., Zhu, K., Wang, H., & Shull, P. B. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3653477 · Cited by 2
“Sensor locations were selected to balance data reliability, participant comfort, and attachment stability, following practices in previous biomechanics and gait analysis literatures [55], [56] [57], [58], and [59].”
Wireless Instrumented Ankle Foot Orthosis (AFO) for Gait Cycle Monitoring
Mahraoui, S., & Serpelloni, M. (2026) · Instruments · doi:10.3390/instruments10020023 · Cited by 2
“It is also sensitive to positioning errors, since small variations in sensor placement after reattachment can affect measurement accuracy [34].”
Paderi, F., Emmanouil, A. A., Boudolos, K. D., & Rousanoglou, E. N. (2026) · Sensors · doi:10.3390/s26113575 · Cited by 2
Lin, W., Xie, F., Zhao, S., Lin, S., He, C., & Wang, Z. (2022) · Spine · doi:10.1097/brs.0000000000004348 · Cited by 2
Nguyen, T.-T., Nguyen, Q.-D., Ha, M.-Q., Hoang, X.-T., & Bui, N.-T. (2023) · International Conference on Health Science and Technology (ICHST) · doi:10.1109/ichst59286.2023.10565352 · Cited by 2
“The sensors have been considered as small, high-performance devices suitable for wearables that do not impede movements [7] [8].”
BackgroundRentz, C., Kaiser, V., Jung, N., Turlach, B. A., Far, M. S., Peterburs, J., Boltes, M., Schnitzler, A., Amunts, K., Dukart, J., et al. (2024) · Sensors · doi:10.3390/s24175598 · Cited by 3
Design of a Lightweight and Flexible Knee Exoskeleton with Compensation Strategy
Wang, Z., Yang, C., Jiang, F., Yi, C., Ding, Z., Wei, B., & Liu, J. (2021) · doi:10.1145/3458648.3460007 · Cited by 2
Zeng, Z., Liu, Y., & Wang, L. (2023) · Journal of Sports Sciences · doi:10.1080/02640414.2023.2259211 · Cited by 1
“Besides running technique, running speed is also one of the important factors affecting the kinematics of lower limb joints related to RRIs (Fukuchi et al., 2017; Hollis et al., 2021; Liu et al., 2022).”
BackgroundInfluentialKanega, S., & Muraoka, Y. (2025) · Sensors · doi:10.3390/s25072273 · Cited by 1
“Wesley et al. (2020) estimated knee joint angles during a timed up-and-go (TUG) task by mounting MIMUs at positions commonly reported in previous studies (four thigh and three shank positions) and examining combinations of thigh and shank MIMU mounting positions [40].”
Kazanski, M. E., LaFollette, C. E., Wells, M. D., Rosenberg, M. C., McKay, J. L., Hajjar, I. M., & Hackney, M. E. (2025) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0000000000000456 · Cited by 1
Khalilipour, N., Tajik, R., Abbasi, A., Mantashloo, Z., & Aziminia, M. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110962 · Cited by 1
Optimising backpack hip belt design: an ergonomic perspective on gait mechanics
Pezeshk, A. F., Aghahasani, F., & Yousefi, M. (2025) · Ergonomics · doi:10.1080/00140139.2025.2563814 · Cited by 1
“For kinematic assessments, six iMU sensors were precisely positioned on the trunk (t4) (niswander, Wang, and Kontson 2020), pelvis (sacrum; mid Psiss), thighs (mid-femur), legs (mid-tibia) and feet (dorsal surface) (Yang, Borgström, and Forsman 2018) to ensure accurate data collection. the design…”
Intelligent prediction of dynamic characteristics during exercise in patients with stroke
Meng, Q., Zhang, N., Bao, C., Zhou, L., Xiao, M., Yang, Z., & Leng, H. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01734-5 · Cited by 2
“Optimization of IMU placement has further been shown to minimize bias and Root Mean Square Error (RMSE), thereby reducing the influence of placement-related errors [15].”
W2W: A Simulated Exploration of IMU Placement Across the Human Body for Designing Smarter Wearable
Ray, L. S. S., Zhou, B., & Lukowicz, P. (2025) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3715071.3750417 · Cited by 1
Li, S., Duan, M., Cheng, H., Jiang, H., Tong, Y., Xia, H., & Liu, L. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3621264 · Cited by 1
“However, in practical applications, IMU-MoCap systems remain subject to soft tissue artifacts (STAs), clothing friction, and obvious body shape changes induced by postural variations [6].”
Kim, J., Xie, L., & Cho, S. (2026) · Scientific Reports · doi:10.1038/s41598-026-39161-8 · Cited by 1
Effects of IMU placement strategies on the accuracy of hip joint angle estimation
Dong, J., Liu, J., Chen, Z., Yang, D., & Yin, X. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2026.2653845 · Cited by 1
Knee joint motion angle prediction method for wearable exoskeleton based on GCN-transformer
Ren, B., & Geng, Y. (2026) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-026-00532-z · Cited by 1
“A placement deviation of just a few centimeters can significantly degrade knee angle estimation, with RMSE increasing to 9.31° in suboptimal configura - tions compared to 4–5° in optimal ones (Niswander et al. 2020 ).”
InfluentialPeper, K. K., Jensen, E., & Haddadin, S. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304782 · Cited by 1
“However, it must be noted that exact sensor placement on the human body part plays a major role when using such sensors [8], [9] and results are generally better with a higher number of sensors.”
BackgroundKnee replacement patients and wearable knee pads
Zhang, Y. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2711/1/012018 · Cited by 1
“Optimization of IMU Sensor Placement for Accurate Measurement of Lower Limb Joint Kinematics during Functional Movements [3]: Accurate measurement of lower limb joint kinematics during functional movements relies heavily on the optimization of IMU sensor placement.”
MethodEffect of anterior cruciate ligament injury on acceleration response of knee joint
Ahmadi, R., Lorgan, S.-H. H., Vaziri, A. S., Tahmasebi, M. N., Moghadam, R. S., & Farahmand, F. (2024) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119241242968 · Cited by 1
“It has been shown that the acceleration data recorded by IMU sensors is affected by the location of the sensor 34 and its attachment method.”
BackgroundFuture directions in clinical application of gait, balance and mobility analysis
Mason, R., Tait, P., Morris, R., & Stuart, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21484-4.00017-x · Cited by 1
Study of spine morphometry based on inertial measure-ment unit
Tan, J. (2024) · International Conference on Electrical Engineering and Control Science (IC2ECS) · doi:10.1109/ic2ecs64405.2024.10928314 · Cited by 1
“Kimberly and Kontson used IMUs to optimize lower limb joint measurement positions, enhancing the reliability of gait kinematic measurements [17].”
Vasquez-Bonilla, A. A., Sepulveda, R. A. Y., Monsalves‐Álvarez, M., Tuesta, M., Bastías, D. M. D., Cortés-Roco, G., Arancibia, J. E. O., Guzmán-Muñoz, E., & López‐Gil, J. F. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10020136 · Cited by 4
“Knee joint load was calculated using the following formula [29]: The sensor was placed laterally near the knee, approximately 3 cm above the knee joint axis [30].”
Application of mobile health technology in post-stroke hemiplegia:review (Preprint)Preprint
Yang, X., Lu, Y., Xie, X., & Hanjiao, L. I. U. (2022) · doi:10.2196/preprints.40728
달리기 속도에 따른 관성 측정 장비(IMU)의 신뢰도 분석
강, 지., 강, 재., & 윤, 석. (2024) · 한국체육학회지 · doi:10.23949/kjpe.2024.9.63.5.34
Pilot Study for a Robot-Assisted Timed Up and Go Assessment*
Story, M., Belaid, K. A., Camp, N., Vagnetti, R., Magistro, D., Zecca, M., & Nuovo, A. G. D. (2024) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros58592.2024.10801568
“[20] proposes a multi-IMU approach for optimal lower limb joint angle accuracy however this is not always feasible outside of a clinical/research setting.”
Bharanidivya, M., Panda, S., & Dhanalakshmi, S. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-97-8946-7_5
Azizi, S., Nikkhoo, M., Rostami, M., Niu, C., & Cheng, C.-H. (2025) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2025.2552432
Swain, T. A., McNarry, M. A., Manzano-Carrasco, S., & Mackintosh, K. A. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.10034
“Indeed, only two studies have sought to validate the orientations of wearable devices relative to such models, both of which used research-grade devices to examine primarily lower-limb movements for clinical applications (Dahl et al., 2020; Niswander et al., 2020).”
Karashima, R., Kishimoto, S., Ibara, T., Hada, K., Motoyama, T., Kawashima, M., MUROFUSHI, Y., & Katoh, H. (2025) · Biomechanics · doi:10.3390/biomechanics5040098
“IMU sensors were attached at three sites: thigh (anterior central surface of the thigh, 5 cm proximal to the knee joint), tibia (tibial tuberosity), and calcaneus (central posterior surface of the calcaneus) [18,25–27].”
Lower Limb Motion Estimation Based on a Small Number of Inertial Measurement Units
Zhou, K., He, C., Jin, Y., Zhang, B., Liu, T., & Wang, B. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3639078
“…have also conducted studies related to the estimation of kinematic information using IMU, and they have used multiple IMU placed at key parts of the human body, and the estimation errors of the ankle and knee joints in these studies were 4.8 –7.3 and 3.6 –6.8 , respectively [20], [21], [30].”
InfluentialAdditional file 1 of Validation of a portable marker-based motion analysis system
Wang, S., Zeng, X., Huangfu, L., Xie, Z., Ma, L., Huang, W., & Zhang, Y. (2021) · Figshare · doi:10.6084/m9.figshare.14906025
Ceglia, A., Mulhaupt, L., Moissenet, F., Begon, M., & Séoud, L. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2025.12.04.692368
Liu, W., Yang, F., Yao, Q., Xu, H., Xu, D., & Qian, L. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1743995
“The walking test length was 6 m, and the plantar pressure board was centered (Niswander et al., 2020; Rantalainen et al., 2020).”
Costa, S. P., Eigenheer, I., Dias, M. A., Ribas, L. C., Salvadeo, D. H. P., & Ranieri, C. M. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6598003
Liu, J., Liu, X., Wang, Z., & Wu, X. (2026) · tm - Technisches Messen · doi:10.1515/teme-2025-0155 · Cited by 1
“…joint angles were computed under different plausible IMU location combinations, error metrics varied substantially, with hip flexion reporting biases as large as ∼ 16 ◦ and RMSE exceeding 20 ◦ in certain functional movements – despite identical tasks and reference optical motion capture [82].”
Fan, L., Lingzhen, 杨. Y., Wang, 王. J., Ding, W., Ren, H., & Zhou, C. (2026) · Sensors · doi:10.3390/s26113341
Baseline-Driven Personalized FPA Retraining Using IMU and AR Feedback for Overground Walking
Chen, X., Murray, N., & Rodrigues, T. B. (2026) · ACM International Conference on Interactive Media Experiences · doi:10.1145/3788851.3812844
Ceglia, A., Lucas, M., Moissenet, F., Begon, M., & Séoud, L. (2026) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2026.103180
Liu, Z., Zhang, Y., He, Y. Q., Paasio, H., Li, C., Semjonova, G., & Xiao, Y. (2026) · Proceedings of the ACM on Human-Computer Interaction · doi:10.1145/3816771
Metadata
- Authors
- Niswander, W., Wang, W., & Kontson, K.
- Affiliations
- United States Food and Drug Administration (US)
- Corresponding author
- Kontson, Kimberly
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-10-22
- Volume
- 20
- Issue
- 21
- Pages
- 5993
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7660215
- OpenAlex
- W3094382181
- Cited by
- 116
- References
- 39
- Citations by year
- 2026: 32 · 2025: 23 · 2024: 23 · 2023: 18 · 2022: 13 · 2021: 7
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Food and Drug Administration (CPI)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, sensor placement, lower limb joint kinematics, hip joint angle, knee joint angle, ankle joint angle, Timed Up and Go test, wearable sensors, gait analysis, measurement accuracy, functional movement, rehabilitation
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Biomechanical Phenomena, Exercise Test, Humans, Range of Motion, Articular, Walking, Lower Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.