Performance Assessment of Portable Optical Particle Spectrometer (POPS)
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm−3. The size distributions measured by both of them remained unaffected up to 15,000 cm−3. While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Borrmann, S., Luo, B., & Mishchenko, M. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00563-7 · Cited by 98 · cited 2×
“The typical relationship between equivalent volume D v and electrical mobility D m diameters is (see e.g., [34]): where C c ( D ) is Cunningham slip correction factor for diameter D, χ t is a dynamic shape factor which “relates the motion of a particle under consideration to that of a spherical…”
Influential
Cited by
Miller, A. J., Ramelli, F., Fuchs, C., Omanovic, N., Spirig, R., Zhang, H., Lohmann, U., Kanji, Z. A., & Henneberger, J. (2024) · Atmospheric Measurement Techniques · doi:10.5194/amt-17-601-2024 · Cited by 26
Pohorsky, R., Baccarini, A., Tolu, J., Winkel, L. H. E., & Schmale, J. (2024) · Atmospheric Measurement Techniques · doi:10.5194/amt-17-731-2024 · Cited by 21
CAMP: an instrumented platform for balloon-borne aerosol particle studies in the lower atmosphere
Pilz, C., Düsing, S., Wehner, B., Müller, T., Siebert, H., Voigtländer, J., & Lonardi, M. (2022) · Atmospheric Measurement Techniques · doi:10.5194/amt-15-6889-2022 · Cited by 20
“A possible explanation for this is the high sensitivity of the instrument light detector to Rayleigh scattering from air molecules or stray light from apertures (Gao et al., 2016; Mei et al., 2020).”
BackgroundMethodInfluential
Metadata
- Authors
- Mei, F., McMeeking, G., Pekour, M., Gao, R.-S., Kulkarni, G., China, S., Telg, H., Dexheimer, D., Tomlinson, J., & Schmid, B.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-11-05
- Volume
- 20
- Issue
- 21
- Pages
- 6294
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3096946127
- Cited by
- 44
- References
- 1
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.