Computer-Aided Diagnosis of Alzheimer’s Disease through Weak Supervision Deep Learning Framework with Attention Mechanism
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Alzheimer’s disease (AD) is the most prevalent neurodegenerative disease causing dementia and poses significant health risks to middle-aged and elderly people. Brain magnetic resonance imaging (MRI) is the most widely used diagnostic method for AD. However, it is challenging to collect sufficient brain imaging data with high-quality annotations. Weakly supervised learning (WSL) is a machine learning technique aimed at learning effective feature representation from limited or low-quality annotations. In this paper, we propose a WSL-based deep learning (DL) framework (ADGNET) consisting of a backbone network with an attention mechanism and a task network for simultaneous image classification and image reconstruction to identify and classify AD using limited annotations. The ADGNET achieves excellent performance based on six evaluation metrics (Kappa, sensitivity, specificity, precision, accuracy, F1-score) on two brain MRI datasets (2D MRI and 3D MRI data) using fine-tuning with only 20% of the labels from both datasets. The ADGNET has an F1-score of 99.61% and sensitivity is 99.69%, outperforming two state-of-the-art models (ResNext WSL and SimCLR). The proposed method represents a potential WSL-based computer-aided diagnosis method for AD in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Gradient-based learning applied to document recognition
Lecun, Y., Bottou, L., Bengio, Y., & Haffner, P. (1998) · Proceedings of the IEEE · doi:10.1109/5.726791 · Cited by 58,805
Caruana, R. (1997) · Machine Learning · doi:10.1023/a:1007379606734 · Cited by 6,636
Advancing research diagnostic criteria for Alzheimer's disease: the IWG-2 criteria
Dubois, B., Feldman, H. H., Jacova, C., Hampel, H., Molinuevo, J. L., Blennow, K., DeKosky, S. T., Gauthier, S., Selkoe, D., Bateman, R., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70090-0 · Cited by 3,321 · cited 1×
“Different forms of neuroimaging techniques have been used in clinical practice to diagnose AD, including computed tomography (CT), positron emission tomography (PET), and magnetic resonance imaging (MRI) [9].”
MethodThe clinical use of structural MRI in Alzheimer disease
Frisoni, G. B., Fox, N. C., Jack, C. R., Scheltens, P., & Thompson, P. M. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2009.215 · Cited by 2,113
Petersen, R. C., Stevens, J. C., Ganguli, M., Tangalos, E. G., Cummings, J. L., & DeKosky, S. T. (2001) · Neurology · doi:10.1212/wnl.56.9.1133 · Cited by 2,065
A brief introduction to weakly supervised learning
Zhou, Z.-H. (2018) · National Science Review · doi:10.1093/nsr/nwx106 · Cited by 1,899
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694 · cited 1×
“Image reconstruction, which is a critical problem in medical imaging, is a technique for creating 2D or 3D images from sets of 1D projections [38].”
MethodExploring the Limits of Weakly Supervised Pretraining
Mahajan, D., Girshick, R., Ramanathan, V., He, K., Paluri, M., Li, Y., Bharambe, A., & van der Maaten, L. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_12 · Cited by 1,224
Cited by
Deep learning for Alzheimer's disease diagnosis: A survey
Khojaste-Sarakhsi, M., Haghighi, S. S., Ghomi, S. M. T. F., & Marchiori, E. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102332 · Cited by 194
Kaur, A., Mittal, M., Bhatti, J. S., Thareja, S., & Singh, S. (2024) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2024.102928 · Cited by 54
Li, Z., Li, H., Ralescu, A. L., Dillman, J. R., Altaye, M., Cecil, K. M., Parikh, N. A., & He, L. (2024) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2024.102993 · Cited by 10
“Various advanced methods, such as Invariant[46], Moco v1-v3 [47, 48], SimCLR [49], BOYL [50], and SimSiam [51], have achieved superior performance in the medical imaging domain [22, 52, 53].”
Method
Metadata
- Authors
- Liang, S., & Gu, Y.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-12-31
- Volume
- 21
- Issue
- 1
- Pages
- 220
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3115324042
- Cited by
- 71
- References
- 12
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.