Wearable Devices for Ergonomics: A Systematic Literature Review
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Wearable devices are pervasive solutions for increasing work efficiency, improving workers’ well-being, and creating interactions between users and the environment anytime and anywhere. Although several studies on their use in various fields have been performed, there are no systematic reviews on their utilisation in ergonomics. Therefore, we conducted a systematic review to identify wearable devices proposed in the scientific literature for ergonomic purposes and analyse how they can support the improvement of ergonomic conditions. Twenty-eight papers were retrieved and analysed thanks to eleven comparison dimensions related to ergonomic factors, purposes, and criteria, populations, application and validation. The majority of the available devices are sensor systems composed of different types and numbers of sensors located in diverse body parts. These solutions also represent the technology most frequently employed for monitoring and reducing the risk of awkward postures. In addition, smartwatches, body-mounted smartphones, insole pressure systems, and vibrotactile feedback interfaces have been developed for evaluating and/or controlling physical loads or postures. The main results and the defined framework of analysis provide an overview of the state of the art of smart wearables in ergonomics, support the selection of the most suitable ones in industrial and non-industrial settings, and suggest future research directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
Cochrane Handbook for Systematic Reviews of Interventions
(2019) · doi:10.1002/9781119536604 · Cited by 14,828
RULA: a survey method for the investigation of work-related upper limb disorders
McAtamney, L., & Nigel Corlett, E. (1993) · Applied Ergonomics · doi:10.1016/0003-6870(93)90080-s · Cited by 3,361 · cited 1×
“, a survey method for investigating work-related upper limb disorders [66].”
MethodErgonomic methods for assessing exposure to risk factors for work-related musculoskeletal disorders
David, G. C. (2005) · Occupational Medicine · doi:10.1093/occmed/kqi082 · Cited by 859 · cited 1×
“, visual observations and video recording [71]) that can be influenced by the assessor’s competencies and/or cannot be objectively conducted [72].”
BackgroundA Survey of Wearable Devices and Challenges
Seneviratne, S., Hu, Y., Nguyen, T., Lan, G., Khalifa, S., Thilakarathna, K., Hassan, M., & Seneviratne, A. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2731979 · Cited by 821 · cited 3×
“This classification highlights the pervasive use of such technology in different fields, as pointed out by several researchers in the literature (e.g., [7,9,15,16,18]).”
BackgroundThe Strain Index: A Proposed Method to Analyze Jobs For Risk of Distal Upper Extremity Disorders
Steven Moore, J., & Garg, A. (1995) · American Industrial Hygiene Association Journal · doi:10.1080/15428119591016863 · Cited by 751 · cited 1×
“, a job analysis methodology for risk of distal upper extremity disorders [67].”
MethodFundamentals of ergonomics in theory and practice
Wilson, J. R. (2000) · Applied Ergonomics · doi:10.1016/s0003-6870(00)00034-x · Cited by 439 · cited 1×
“In such a context, the role of ergonomics is two-fold: the first one is to understand purposive interactions between people and artefacts and especially to consider the capabilities, needs, desires, and limitations of people in such interactions, and the second one comprises a contribution to the design of interacting…”
BackgroundKarwowski, W. (2005) · Ergonomics · doi:10.1080/00140130400029167 · Cited by 342
Yan, X., Li, H., Li, A. R., & Zhang, H. (2017) · Automation in Construction · doi:10.1016/j.autcon.2016.11.007 · Cited by 303 · cited 8×
“As an alternative to visual feedback, alarm sounds by means of a smartphone application are proposed for warning users when ergonomically hazardous operational postures and holding time leading to lower back and neck pain are detected [64].”
BackgroundMethodInfluentialErgonomic analysis of construction worker's body postures using wearable mobile sensors
Nath, N. D., Akhavian, R., & Behzadan, A. H. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.02.007 · Cited by 238 · cited 10×
“[61] propose a body-mounted smartphone, while Valero et al.”
BackgroundInfluentialValero, E., Sivanathan, A., Bosché, F., & Abdel-Wahab, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.11.020 · Cited by 222 · cited 1×
“[73], “the evolution of technologies has been driven by not only improvement in measurement accuracy and precision, but also reduction in intrusiveness and enhanced wearability”.”
BackgroundA data-driven approach to modeling physical fatigue in the workplace using wearable sensors
Sedighi Maman, Z., Alamdar Yazdi, M. A., Cavuoto, L. A., & Megahed, F. M. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.02.001 · Cited by 218 · cited 3×
“[62] Sensor system No Hand Trunk Lower extremity Physical load Physically demanding jobs (e.”
BackgroundIndustrial wearable system: the human-centric empowering technology in Industry 4.0
Kong, X. T. R., Luo, H., Huang, G. Q., & Yang, X. (2019) · Journal of Intelligent Manufacturing · doi:10.1007/s10845-018-1416-9 · Cited by 209
Niknejad, N., Ismail, W. B., Mardani, A., Liao, H., & Ghani, I. (2020) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2020.103529 · Cited by 206 · cited 3×
“This classification highlights the pervasive use of such technology in different fields, as pointed out by several researchers in the literature (e.g., [7,9,15,16,18]).”
BackgroundReview of Wearable Device Technology and Its Applications to the Mining Industry
Mardonova, M., & Choi, Y. (2018) · Energies · doi:10.3390/en11030547 · Cited by 201 · cited 4×
“Interesting different taxonomies can be found in Mardonova and Choi [3], Khakurel et al. [4], Mewara et al. [7], and Park and Jayaraman [16].”
BackgroundInfluentialDomain-specific innovativeness and new product adoption: A case of wearable devices
Jeong, S. C., Kim, S.-H., Park, J. Y., & Choi, B. (2017) · Telematics and Informatics · doi:10.1016/j.tele.2016.09.001 · Cited by 175
Antwi‐Afari, M. F., Li, H., Yu, Y., & Kong, L. (2018) · Automation in Construction · doi:10.1016/j.autcon.2018.10.004 · Cited by 164 · cited 8×
“Other portions on which a wearable technology can be put on are foot in the case of insole pressure systems [46,47], hand for a smartwatch [54], or head during the smart glasses use [45].”
BackgroundMethodInfluentialTapping into the wearable device revolution in the work environment: a systematic review
Khakurel, J., Melkas, H., & Porras, J. (2018) · Information Technology & People · doi:10.1108/itp-03-2017-0076 · Cited by 163 · cited 2×
“They represent a new means of addressing the needs of many industries [3], and have the potential to increase work efficiency among employees, improve workers’ physical well-being, and reduce work-related injuries [4].”
BackgroundValero, E., Sivanathan, A., Bosché, F., & Abdel-Wahab, M. (2017) · Automation in Construction · doi:10.1016/j.autcon.2017.08.001 · Cited by 146 · cited 5×
“The sensors should be attached to the subject’s body by means of elastic straps and fitted tightly to body segments in order to prevent slippage that could cause incorrect recognition of postures and movements [63].”
BackgroundMethodInfluentialAutomated ergonomic risk monitoring using body-mounted sensors and machine learning
Nath, N. D., Chaspari, T., & Behzadan, A. H. (2018) · Advanced Engineering Informatics · doi:10.1016/j.aei.2018.08.020 · Cited by 144 · cited 5×
“[60] Body- mounted smart- phone Partly Upper extremity Trunk Physical load Heavy and repetitive activities, including lifting, lowering, carrying, pushing, and pulling Assessment Post-exposure recognition of activities using a support vector machine learning classifier, using MATLAB®, and risk level estimation UMass L…”
BackgroundMethodInfluentialA narrative review on contemporary and emerging uses of inertial sensing in occupational ergonomics
Lim, S. I., & D’Souza, C. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.102937 · Cited by 135 · cited 2×
“Also in the ergonomic field some reviews have been published, but considering only a limited scope of the wearable device use: Tsao et al. [19] summarise the applications of wearable sensors for human work and status evaluation, whereas Lim and D’Souza [20] synthesise the literature on body-worn inertial sensing for as…”
BackgroundPeppoloni, L., Filippeschi, A., Ruffaldi, E., & Avizzano, C. A. (2015) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2015.07.002 · Cited by 133 · cited 10×
“Such component combines information obtained from multiple electromechanical sensors (e.g., accelerometers, gyroscopes, and magnetometers) [57], and is self-contained and unobtrusive [44].”
BackgroundMethodInfluentialCheng, J. W., & Mitomo, H. (2016) · Telematics and Informatics · doi:10.1016/j.tele.2016.09.010 · Cited by 119 · cited 1×
“Other definitions underpin its ability to create interaction between users and the smart environment anytime and anywhere [9], and to measure information such as the users’ locations, environments, movements, and vital signs [10].”
BackgroundWearable Stretch Sensors for Human Movement Monitoring and Fall Detection in Ergonomics
Chander, H., Burch, R. F. V., Talegaonkar, P., Saucier, D. N., Luczak, T., Ball, J. E., Turner, A. J., Arachchige, S. N. K. K., Carroll, W., Smith, B. K., et al. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17103554 · Cited by 113 · cited 3×
“The adoption of wearable technology appears particularly interesting for ergonomic purposes because of the well-known properties of assisting the users anywhere [21], sensing, collecting, and uploading data in a 24 × 7 manner [18], and monitoring continuously human performance [11].”
BackgroundConforti, I., Mileti, I., Prete, Z. D., & Palermo, E. (2020) · Sensors · doi:10.3390/s20061557 · Cited by 109 · cited 7×
“Furthermore, taking inspiration from Conforti et al. [13], the estimation of risks through sensor systems promotes the design of setups that are not bulky and are suitable for each working activity.”
BackgroundMethodInfluentialValidation of a Wearable IMU System for Gait Analysis: Protocol and Application to a New System
Fusca, M. C., Negrini, F., Perego, P., Magoni, L., Molteni, F., & Andreoni, G. (2018) · Applied Sciences · doi:10.3390/app8071167 · Cited by 109 · cited 1×
“Papers proposing only a design approach or validation protocol of wearable devices (e.g., [36]).”
BackgroundMeasuring Ergonomic Risk in Operating Surgeons by Using Wearable Technology
Meltzer, A. J., Hallbeck, M. S., Morrow, M. M. B., Lowndes, B. R., Davila, V. J., Stone, W. M., & Money, S. R. (2020) · JAMA Surgery · doi:10.1001/jamasurg.2019.6384 · Cited by 104 · cited 3×
“[59] evaluate the ergonomic risks considering 53 surgeons representing 12 surgical specialties, Giannini et al.”
BackgroundMethodAntwi‐Afari, M. F., Li, H., Umer, W., Yu, Y., & Xing, X. (2020) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001849 · Cited by 94 · cited 5×
“Other portions on which a wearable technology can be put on are foot in the case of insole pressure systems [46,47], hand for a smartwatch [54], or head during the smart glasses use [45].”
BackgroundMethodInfluentialWearables: Fundamentals, advancements, and a roadmap for the future
Park, S., & Jayaraman, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00001-2 · Cited by 93
Smart Vest for Real-Time Postural Biofeedback and Ergonomic Risk Assessment
Cerqueira, S. M., da Silva, A. F., & Santos, C. P. (2020) · IEEE Access · doi:10.1109/access.2020.3000673 · Cited by 69 · cited 10×
“Other 4 studies described in 5 papers [43,44,48,50,59] propose wearable devices to assess postures on the basis of Rapid Upper Limb Assessment (RULA), i.”
BackgroundMethodInfluentialPhysical Workload Tracking Using Human Activity Recognition with Wearable Devices
Manjarrés, J., Narváez, P., Gasser, K., Percybrooks, W., & Pardo, M. (2019) · Sensors · doi:10.3390/s20010039 · Cited by 68 · cited 6×
“[58] test the reliability of their sensor system-based activity classifier with twenty subjects, and”
BackgroundMethodInfluentialIMU-Based Motion Capture Wearable System for Ergonomic Assessment in Industrial Environment
Caputo, F., Greco, A., D’Amato, E., Notaro, I., & Spada, S. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-94619-1_21 · Cited by 59
Geršak, V., Vitulić, H. S., Prosen, S., Starc, G., Humar, I., & Geršak, G. (2019) · Computer Communications · doi:10.1016/j.comcom.2019.12.019 · Cited by 55
ErgoTac: A Tactile Feedback Interface for Improving Human Ergonomics in Workplaces
Kim, W., Lorenzini, M., Kapicioglu, K., & Ajoudani, A. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2864356 · Cited by 55 · cited 5×
“[21] consider the amplitudes of the overloading joint torques for applying vibrotactile stimuli to the body joints.”
BackgroundMethodInfluentialRossi, D., Bertoloni, E., Fenaroli, M., Marciano, F., & Alberti, M. (2013) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2013.04.009 · Cited by 52 · cited 1×
“Furthermore, the standards reflect the views of many stakeholders including technical experts, government representatives, and consumers, and represent traditional documents considered by companies to conduct their activities [76].”
BackgroundSelf-citationHuman Work and Status Evaluation Based on Wearable Sensors in Human Factors and Ergonomics: A Review
Tsao, L., Li, L., & Ma, L. (2018) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2018.2878824 · Cited by 49 · cited 1×
“[19] summarise the applications of wearable sensors for human work and status evaluation, whereas Lim and D’Souza [20] synthesise the literature on body-worn inertial sensing for assessing biomechanical exposures and musculoskeletal disorder risk resulting from physical work.”
BackgroundLo, J. C., Sehic, E., & Meijer, S. (2017) · Journal of Cognitive Engineering and Decision Making · doi:10.1177/1555343417716040 · Cited by 48 · cited 1×
“Papers proposing a comparison among wearable devices considering only features not correlated with ergonomics (e.g., [33]) 5.”
BackgroundWearable Sensor Network for Biomechanical Overload Assessment in Manual Material Handling
Giannini, P., Bassani, G., Avizzano, C. A., & Filippeschi, A. (2020) · Sensors · doi:10.3390/s20143877 · Cited by 45 · cited 5×
“[52] assess their system in the activity of lift-on/lift-off of containers in a port, Lenzi et al.”
BackgroundMethodInfluentialAssessment of task ergonomics with an upper limb wearable device
Peppoloni, L., Filippeschi, A., & Ruffaldi, E. (2014) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med.2014.6961394 · Cited by 30 · cited 10×
“The number of papers is different from the number of wearable devices because some authors have discussed their research studies in more than one paper: Caputo et al. [39–41], Conforti et al. [13,42], and Peppoloni et al. [43,44].”
BackgroundMethodInfluentialA Novel Generation of Ergonomic Upper-Limb Wearable Robots: Design Challenges and Solutions
Ercolini, G., Trigili, E., Baldoni, A., Crea, S., & Vitiello, N. (2018) · Robotica · doi:10.1017/s0263574718001340 · Cited by 24 · cited 1×
“Papers proposing only the ergonomic evaluation of a wearable device (e.g., [34]).”
BackgroundHuman Posture Tracking System for Industrial Process Design and Assessment
Caputo, F., D’Amato, E., Greco, A., Notaro, I., & Spada, S. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-73888-8_70 · Cited by 23 · cited 6×
“The number of papers is different from the number of wearable devices because some authors have discussed their research studies in more than one paper: Caputo et al. [39–41], Conforti et al. [13,42], and Peppoloni et al. [43,44].”
BackgroundInfluentialPredictive models to assess Oxygen Deficiency Hazard (ODH): A systematic review
Stefana, E., Marciano, F., Cocca, P., & Alberti, M. (2015) · Safety Science · doi:10.1016/j.ssci.2015.01.008 · Cited by 22 · cited 2×
“[37]: (1) title evaluation, (2) abstract and keywords evaluation, and (3) full‐text evaluation.”
BackgroundSelf-citationDevelopment of a Wearable IMU System for Automatically Assessing Lifting Risk Factors
Lu, M., Barim, M. S., Feng, S., Hughes, G., Hayden, M. A., & Werren, D. M. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-49904-4_15 · Cited by 22 · cited 4×
“Such results also emphasise the statement by Lu et al. [57], according to which “the application of IMUs for tracking human motion as a part of the ergonomic assessment is becoming popular because the collection of the human body motion does not greatly interrupt with workers’ job performance”.”
BackgroundMethodResultInfluentialA Wearable Vibrotactile Interface for Unfavorable Posture Awareness Warning
Lins, C., Fudickar, S., Gerka, A., & Hein, A. (2018) · International Conference on Information and Communication Technologies for Ageing Well and e-Health (ICT4AWE) · doi:10.5220/0006734901780183 · Cited by 21 · cited 4×
“[56] Sensor system and feedback interface No Upper extremity Hand Trunk Lower extremity Posture Tasks requiring awkward postures Assessment Improvement Real-time recognition of awkward postures using a predefined classifier, and feedback provided by vibrotactile motors OWAS Workers (industry) Tests/Simulations”
BackgroundMethodInfluentialConforti, I., Mileti, I., Panariello, D., et al. (2020) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot48571.2020.9138259 · Cited by 19 · cited 1×
“[49] Sensor system No Upper extremity Trunk Lower extremity Foot Physical load Manual material handling (e.”
BackgroundQuestions to Improve Quality of Life with Wearables: Humans, Technology, and the World
Duval, S., & Hashizume, H. (2006) · International Conference on Hybrid Information Technology (ICHIT) · doi:10.1109/ichit.2006.253492 · Cited by 18
Assessing ergonomics and biomechanical risk in manual handling of loads through a wearable system
Conforti, I., Mileti, I., Prete, Z. D., & Palermo, E. (2019) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroi4.2019.8792843 · Cited by 18 · cited 5×
“The number of papers is different from the number of wearable devices because some authors have discussed their research studies in more than one paper: Caputo et al. [39–41], Conforti et al. [13,42], and Peppoloni et al. [43,44].”
BackgroundMethodInfluentialAssessment of biomechanical risk at work: practical approaches and tools.
Cocca, P., Marciano, F., & Rossi, D. (2008) · PubMed · Cited by 14
Self-citationA Human Postures Inertial Tracking System for Ergonomic Assessments
Caputo, F., Greco, A., D’Amato, E., Notaro, I., Sardo, M. L., Spada, S., & Ghibaudo, L. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-96068-5_19 · Cited by 13 · cited 6×
“The number of papers is different from the number of wearable devices because some authors have discussed their research studies in more than one paper: Caputo et al. [39–41], Conforti et al. [13,42], and Peppoloni et al. [43,44].”
BackgroundInfluentialContinuous Measurement of Muscle Fatigue Using Wearable Sensors During Light Manual Operations
Fu, J., Liang Ma, A., Tsao, L., & Zhang, Z. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-22216-1_20 · Cited by 11
Questions to Improve Quality of Life with Wearables: Humans, Technology, and the World
Duval, S., & Hashizume, H. (2006) · International Conference on Hybrid Information Technology (ICHIT) · doi:10.1109/ichit.2006.196 · Cited by 9 · cited 2×
“Additionally, it should improve the body condition, comfort, and safety of his/her wearer and, possibly, of surrounding or distant people, and its design should be gender and culture—oriented [2].”
BackgroundA Conceptual Design of Intelligent Shoes for Pregnant Women
Dimou, E., Manavis, A., Papachristou, E., & Kyratsis, P. (2017) · Lecture notes in electrical engineering · doi:10.1007/978-3-319-48511-9_6 · Cited by 9 · cited 1×
“Among these possible categorisations, Dimou et al. [17] consider the field of use of smart wearables, such as lifestyle, entertainment, medical, fitness, gaming, and industrial.”
BackgroundLee, W., Lin, J., Bao, S. S., et al. (2019) · ASCE International Conference on Computing in Civil Engineering (i3CE) · doi:10.1061/9780784482438.074 · Cited by 6 · cited 1×
“[77] emphasise that “WMSDs are prevalent among construction workers engaged in repetitive motions, heavy lifting, awkward postures, and high-force exertions to perform tasks”, and Palikhe et al.”
Zhou, Y., David, B. T., & Chalon, R. (2012) · doi:10.1145/2652574.2653418 · Cited by 5
Cited by
Machine Learning and Smart Devices for Diabetes Management: Systematic Review
Makroum, M. A., Adda, M., Bouzouane, A., & Ibrahim, H. (2022) · Sensors · doi:10.3390/s22051843 · Cited by 145
“A systematic review is an explicit and reproducible research methodology that identifies all associated experiments and also summarizes the state of the art, in order to answer one or more fundamental research questions on a particular topic [23,24].”
BackgroundWearable Devices for Environmental Monitoring in the Built Environment: A Systematic Review
Salamone, F., Masullo, M., & Sibilio, S. (2021) · Sensors · doi:10.3390/s21144727 · Cited by 89
“While there are different practical experiences with the use of wearables for ergonomics [13] or health monitoring [14,15] and workers’ safety [16], few researchers have investigated the impact of IoT-based infrastructure in environmental monitoring in the last decades.”
BackgroundMethod
Metadata
- Authors
- Stefana, E., Marciano, F., Rossi, D., Cocca, P., & Tomasoni, G.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-01-24
- Volume
- 21
- Issue
- 3
- Pages
- 777
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3121322113
- Cited by
- 177
- References
- 56
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.