The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Open accessAbstract
Electrochemical impedance spectroscopy (EIS) is a powerful technique used for the analysis of interfacial properties related to bio-recognition events occurring at the electrode surface, such as antibody–antigen recognition, substrate–enzyme interaction, or whole cell capturing. Thus, EIS could be exploited in several important biomedical diagnosis and environmental applications. However, the EIS is one of the most complex electrochemical methods, therefore, this review introduced the basic concepts and the theoretical background of the impedimetric technique along with the state of the art of the impedimetric biosensors and the impact of nanomaterials on the EIS performance. The use of nanomaterials such as nanoparticles, nanotubes, nanowires, and nanocomposites provided catalytic activity, enhanced sensing elements immobilization, promoted faster electron transfer, and increased reliability and accuracy of the reported EIS sensors. Thus, the EIS was used for the effective quantitative and qualitative detections of pathogens, DNA, cancer-associated biomarkers, etc. Through this review article, intensive literature review is provided to highlight the impact of nanomaterials on enhancing the analytical features of impedimetric biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The reduction of graphene oxide
Pei, S., & Cheng, H.-M. (2012) · Carbon · doi:10.1016/j.carbon.2011.11.010 · Cited by 5,164
Graphene/Polymer Nanocomposites
Kim, H., Abdala, A. A., & Macosko, C. W. (2010) · Macromolecules · doi:10.1021/ma100572e · Cited by 3,406
Georgakilas, V., Perman, J. A., Tucek, J., & Zboril, R. (2015) · Chemical Reviews · doi:10.1021/cr500304f · Cited by 2,147
Synthesis of Graphene Oxide using Modified Hummers Method: Solvent Influence
Zaaba, N. I., Foo, K. L., Hashim, U., Tan, S. J., Liu, W.-W., & Voon, C. H. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.04.118 · Cited by 1,564
Electrochemical Impedance Spectroscopy and its Applications
Lasia, A. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8933-7 · Cited by 1,355
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Electrochemical Impedance Spectroscopy of Metal Oxide Electrodes for Energy Applications
Bredar, A. R. C., Chown, A. L., Burton, A. R., & Farnum, B. H. (2020) · ACS Applied Energy Materials · doi:10.1021/acsaem.9b01965 · Cited by 1,035
Review of Carbon and Graphene Quantum Dots for Sensing
Li, M., Chen, T., Gooding, J. J., & Liu, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00514 · Cited by 991
Troponin: the biomarker of choice for the detection of cardiac injury
Babuin, L., & Jaffe, A. S. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050141 · Cited by 686
Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis
Cho, I.-H., Kim, D. H., & Park, S. (2020) · Biomaterials Research · doi:10.1186/s40824-019-0181-y · Cited by 638
Role of oxygen functional groups in reduced graphene oxide for lubrication
Gupta, B., Kumar, N., Panda, K., Kanan, V., Joshi, S., & Visoly-Fisher, I. (2017) · Scientific Reports · doi:10.1038/srep45030 · Cited by 620
Wang, Y., & Xia, Y. (2004) · Nano Letters · doi:10.1021/nl048689j · Cited by 514
Recent Progress in Graphene/Polymer Nanocomposites
Sun, X., Huang, C., Wang, L., Liang, L., Cheng, Y., Fei, W., & Li, Y. (2021) · Advanced Materials · doi:10.1002/adma.202001105 · Cited by 490
Encyclopedia of Applied Electrochemistry
(2014) · Springer eBooks · doi:10.1007/978-1-4419-6996-5 · Cited by 482
Impedimetric immunosensors—A review
Prodromidis, M. I. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2009.01.081 · Cited by 347
Electrical nanogap devices for biosensing
Chen, X., Guo, Z., Yang, G.-M., Li, J., Li, M.-Q., Liu, J.-H., & Huang, X.-J. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70201-7 · Cited by 326
A review on impedimetric biosensors
Bahadır, E. B., & Sezgintürk, M. K. (2016) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.3109/21691401.2014.942456 · Cited by 307
An Overview of Carbon Nanotubes and Graphene for Biosensing Applications
Zhu, Z. (2017) · Nano-Micro Letters · doi:10.1007/s40820-017-0128-6 · Cited by 303
Graphene Platform for Hairpin-DNA-Based Impedimetric Genosensing
Bonanni, A., & Pumera, M. (2011) · ACS Nano · doi:10.1021/nn200091p · Cited by 298
Encyclopedia of Nanotechnology
(2012) · Springer eBooks · doi:10.1007/978-90-481-9751-4 · Cited by 277
A review on carbon nanotubes in biosensor devices and their applications in medicine
Sireesha, M., Jagadeesh Babu, V., Kranthi Kiran, A. S., & Ramakrishna, S. (2018) · Nanocomposites · doi:10.1080/20550324.2018.1478765 · Cited by 271
Li, T., Hu, W., & Zhu, D. (2010) · Advanced Materials · doi:10.1002/adma.200900864 · Cited by 269
Lv, S., Zhang, K., Zhu, L., Tang, D., Niessner, R., & Knopp, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03177 · Cited by 240
Voltammetric techniques of analysis: the essentials
Scholz, F. (2015) · ChemTexts · doi:10.1007/s40828-015-0016-y · Cited by 232
Nanochannels Preparation and Application in Biosensing
de la Escosura-Muñiz, A., & Merkoçi, A. (2012) · ACS Nano · doi:10.1021/nn301368z · Cited by 219
Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection
Chowdhury, A. D., Takemura, K., Li, T.-C., Suzuki, T., & Park, E. Y. (2019) · Nature Communications · doi:10.1038/s41467-019-11644-5 · Cited by 194
Cardiac troponin I as diagnostic and prognostic marker in severe heart failure
La Vecchia, L., Mezzena, G., Zanolla, L., Paccanaro, M., Varotto, L., Bonanno, C., & Ometto, R. (2000) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(00)00120-0 · Cited by 191
A review on impedimetric immunosensors for pathogen and biomarker detection
Leva-Bueno, J., Peyman, S. A., & Millner, P. A. (2020) · Medical Microbiology and Immunology · doi:10.1007/s00430-020-00668-0 · Cited by 187
Bertok, T., Lorencova, L., Chocholova, E., Jane, E., Vikartovska, A., Kasak, P., & Tkac, J. (2019) · ChemElectroChem · doi:10.1002/celc.201800848 · Cited by 180
ZnO Nanostructures Application in Electrochemistry: Influence of Morphology
Šulčiūtė, A., Nishimura, K., Gilshtein, E., Cesano, F., Viscardi, G., Nasibulin, A. G., Ohno, Y., & Račkauskas, S. (2021) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.0c08459 · Cited by 165
de la Escosura‐Muñiz, A., & Merkoçi, A. (2011) · Small · doi:10.1002/smll.201002349 · Cited by 153
Madianos, L., Tsekenis, G., Skotadis, E., Patsiouras, L., & Tsoukalas, D. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.10.034 · Cited by 149
Li, X., Qin, Z., Fu, H., Li, T., Peng, R., Li, Z., Rini, J. M., & Liu, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112672 · Cited by 145
Decorated graphene sheets for label-free DNA impedance biosensing
Hu, Y., Wang, K., Zhang, Q., Li, F., Wu, T., & Niu, L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.045 · Cited by 130
Azimzadeh, M., Nasirizadeh, N., Rahaie, M., & Naderi‐Manesh, H. (2017) · RSC Advances · doi:10.1039/c7ra09767k · Cited by 127
Yang, Y., Li, C., Yin, L., Liu, M., Wang, Z., Shu, Y., & Li, G. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am500912m · Cited by 120
Cherian, C. T., Zheng, M., Reddy, M. V., Chowdari, B. V. R., & Sow, C. H. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am400802j · Cited by 120
Pure graphene oxide doped conducting polymer nanocomposite for bio-interfacing
Luo, X., Weaver, C. L., Tan, S., & Cui, X. T. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb00006k · Cited by 118
Yagati, A. K., Pyun, J., Min, J., & Cho, S. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2015.10.002 · Cited by 97
Magar, H. S., Ghica, M. E., Abbas, M. N., & Brett, C. M. A. (2017) · Talanta · doi:10.1016/j.talanta.2017.02.048 · Cited by 96
Self-citationReview—Nonlinear Electrochemical Impedance Spectroscopy
Fasmin, F., & Srinivasan, R. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.0391707jes · Cited by 96
Point-of-Care Diagnostics of COVID-19: From Current Work to Future Perspectives
Hussein, H. A., Hassan, R. Y. A., Chino, M., & Febbraio, F. (2020) · Sensors · doi:10.3390/s20154289 · Cited by 92
Self-citationMolecular Recognition and Specific Interactions for Biosensing Applications
Kim, D. C., & Kang, D. J. (2008) · Sensors · doi:10.3390/s8106605 · Cited by 91
Biosensors Incorporating Bimetallic Nanoparticles
Rick, J. F., Tsai, M., & Hwang, B. (2015) · Nanomaterials · doi:10.3390/nano6010005 · Cited by 79
Balakrishnan, S. R., Hashim, U., Letchumanan, G. R., Kashif, M., Ruslinda, A. R., Liu, W., Perumal, V., Prasad, R. H., Foo, K. L., & POOPALAN, P. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.09.027 · Cited by 75
Biosensors for medical applications
Higson, S. P. J. (2012) · Woodhead Publishing Limited eBooks · doi:10.1533/9780857097187 · Cited by 73
Multifunctional Nanotechnology-Enabled Sensors for Rapid Capture and Detection of Pathogens
Mustafa, F., Hassan, R. Y. A., & Andreescu, S. (2017) · Sensors · doi:10.3390/s17092121 · Cited by 73
Self-citationChen, C.-C., Lai, Z.-L., Wang, G., & Wu, C. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.028 · Cited by 71
Fayazfar, H. R., Afshar, A., Dolati, M., & Dolati, A. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.05.029 · Cited by 68
Enzyme-free impedimetric glucose sensor based on gold nanoparticles/polyaniline composite film
Ahammad, A. J. S., Mamun, A. A., Akter, T., Mamun, M. A., Faraezi, S., & Monira, F. Z. (2016) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-016-3199-2 · Cited by 66
SOI nanowire for the high-sensitive detection of HBsAg and α-fetoprotein
Ivanov, Y. D., Pleshakova, T. O., Kozlov, A. F., Malsagova, K. A., Krohin, N. V., Shumyantseva, V. V., Shumov, I. D., Popov, V. P., Naumova, O. V., Fomin, B. I., et al. (2012) · Lab on a Chip · doi:10.1039/c2lc40555e · Cited by 56
Nanoparticle-Enhanced Sensitivity of a Nanogap-Interdigitated Electrode Array Impedimetric Biosensor
Singh, K. V., Bhura, D. K., Nandamuri, G., Whited, A. M., Evans, D. R., King, J., & Solanki, R. (2011) · Langmuir · doi:10.1021/la202546a · Cited by 56
Nanowires array modified electrode for enhanced electrochemical detection of nucleic acid
Ramulu, T. S., Venu, R., Sinha, B., Lim, B., Jeon, S.-M., Yoon, S. S., & Kim, C. G. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.034 · Cited by 54
Mashhadizadeh, M. H., & Talemi, R. P. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.10.082 · Cited by 52
Hassan, R. Y. A., Mekawy, M. M., Ramnani, P., & Mulchandani, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.01.060 · Cited by 44
Self-citationLima, D., Inaba, J., Lopes, L. C., Calaça, G. N., Weinert, P. L., Fogaça, R. L., de Moura, J. F., Alvarenga, L. M., de Figueiredo, B. C., Wohnrath, K., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.02.063 · Cited by 41
Magar, H. S., Abbas, M. N., Ali, M. B., & Ahmed, M. A. (2020) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-020-04500-w · Cited by 40
Self-citationKashish, K., Gupta, S., Dubey, S. K., & Prakash, R. (2015) · Analytical Methods · doi:10.1039/c5ay00167f · Cited by 39
Li, L., Wang, S., Yang, T., Huang, S., & Wang, J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.12.039 · Cited by 38
Yaman, Y. T., Vural, O. A., Bolat, G., & Abacı, S. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128343 · Cited by 35
Slouka, C., Wurm, D. J., Brunauer, G., Welzl, A., Oliver Spadiut, A., Fleig, J., & Herwig, C. (2016) · Sensors · doi:10.3390/s16111900 · Cited by 32
Current Trends in Nanoporous Anodized Alumina Platforms for Biosensing Applications
Sriram, G., Patil, P. D., Bhat, M. P., Hegde, R. M., Ajeya, K. V., Udachyan, I., Bhavya, M. B., Gatti, M. G., Uthappa, U. T., Neelgund, G. M., et al. (2016) · Journal of Nanomaterials · doi:10.1155/2016/1753574 · Cited by 29
Impedimetric Detection of DNA Damage with the Sensor Based on Silver Nanoparticles and Neutral Red
Kuzin, Y. I., Porfireva, A. V., Stepanova, V., Evtugyn, V. G., Stoikov, I. I., Evtugyn, G. A., & Hianik, T. (2015) · Electroanalysis · doi:10.1002/elan.201500312 · Cited by 26
Research works printed but not linked: 46
- Ozdemir, 2013, A Label-Free Potentiometric Sensor Principle for the Detection of Antibody–Antigen Interactions, Anal. Chem., 85, 4770, 10.1021/ac400514u · doi:10.1021/ac400514u
- Page, 1944, Recent Developments in Polarographic Analysis, Nature, 154, 199, 10.1038/154199a0 · doi:10.1038/154199a0
- Chauhan, 2021, Contemporary voltammetric techniques and its application to pesticide analysis: A review, Mater. Today Proc., 37, 3231, 10.1016/j.matpr.2020.09.092 · doi:10.1016/j.matpr.2020.09.092
- Méndez-Vilas, A. (2005). Electrochemical Impedance Spectroscopy as a Tool for Electrical and Structural Characterizations of Membranes in Contact with Electrolyte Solutions. Recent Advances in Multidisciplinary Applied Physics, Elsevier Science Ltd.
- Kreysa, G., Ota, K.-i., and Savinell, R.F. (2014). Electrochemical Impedance Spectroscopy (EIS) Applications to Sensors and Diagnostics. Encyclopedia of Applied Electrochemistry, Springer. · DOI · Paper page
- Sawan, M. (2015). Impedance Spectroscopy for Biosensing: Circuits and Applications. Handbook of Biochips: Integrated Circuits and Systems for Biology and Medicine, Springer. · doi:10.1007/978-1-4614-6623-9
- Ha, 2019, Implementation of Second-Generation Fourier Transform Electrochemical Impedance Spectroscopy with Commercial Potentiostat and Application to Time-Resolved Electrochemical Impedance Spectroscopy, Anal. Chem., 91, 14208, 10.1021/acs.analchem.9b03226 · doi:10.1021/acs.analchem.9b03226
- Lasia, A. (2014). Definition of Impedance and Impedance of Electrical Circuits. Electrochemical Impedance Spectroscopy and Its Applications, Springer. · DOI · Paper page
- Sun, J., and Liu, Y. (2019). Unique Constant Phase Element Behavior of the Electrolyte-Graphene Interface. Nanomaterials, 9. · doi:10.3390/nano9070923
- Karunakaran, C., Bhargava, K., and Benjamin, R. (2015). Biosensors and Bioelectronics, Elsevier.
- Sedki, 2019, Online-monitoring of biofilm formation using nanostructured electrode surfaces, Mater. Sci. Eng. C, 100, 178, 10.1016/j.msec.2019.02.112 · DOI
- Anusha, T., Sai Bhavani, K., Shankumkha Kumar, J.V., Kumar Brahman, P., and Hassan, R.Y.A. (2021). Fabrication of electrochemical immunosensor based on GCN-β-CD/Au nanocomposite for the monitoring of vitamin D deficiency. Bioelectrochemistry, 107935. In Press. · doi:10.1016/j.bioelechem.2021.107935
- Izadi, 2019, An impedimetric aptasensor for ultrasensitive detection of Penicillin G based on the use of reduced graphene oxide and gold nanoparticles, Microchim. Acta, 186, 372, 10.1007/s00604-019-3510-x · doi:10.1007/s00604-019-3510-x
- Manickam, 2010, A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array, IEEE Trans. Biomed. Circuits Syst., 4, 379, 10.1109/TBCAS.2010.2081669 · DOI
- Espinosa, 2019, Iron Oxide Nanoflower–Based Screen Print Electrode for Enhancement Removal of Organic Dye Using Electrochemical Approach, Electrocatalysis, 10, 663, 10.1007/s12678-019-00554-1 · doi:10.1007/s12678-019-00554-1
- Mahmoud, 2019, Development of an impedimetric non enzymatic sensor based on ZnO and Cu doped ZnO nanoparticles for the detection of glucose, J. Alloy. Compd., 786, 960, 10.1016/j.jallcom.2019.02.060 · doi:10.1016/j.jallcom.2019.02.060
- Ghica, 2019, Impedimetric sensor for tyramine based on gold nanoparticle doped-poly(8-anilino-1-naphthalene sulphonic acid) modified gold electrodes, Talanta, 195, 604, 10.1016/j.talanta.2018.11.054 · doi:10.1016/j.talanta.2018.11.054
- Gao, 2011, Highly sensitive impedimetric sensing of DNA hybridization based on the target DNA-induced displacement of gold nanoparticles attached to ssDNA probe, Electrochem. Commun., 13, 335, 10.1016/j.elecom.2011.01.018 · doi:10.1016/j.elecom.2011.01.018
- Jolly, 2017, Self-assembled gold nanoparticles for impedimetric and amperometric detection of a prostate cancer biomarker, Sens. Actuators B Chem., 251, 637, 10.1016/j.snb.2017.05.040 · doi:10.1016/j.snb.2017.05.040
- Yeter, 2021, An electrochemical label-free DNA impedimetric sensor with AuNP-modified glass fiber/carbonaceous electrode for the detection of HIV-1 DNA, Chem. Pap., 75, 77, 10.1007/s11696-020-01280-5 · doi:10.1007/s11696-020-01280-5
- Lin, 2019, An impedimetric biosensor for E. coli O157:H7 based on the use of self-assembled gold nanoparticles and protein G, Microchim. Acta, 186, 169, 10.1007/s00604-019-3282-3 · doi:10.1007/s00604-019-3282-3
- Elshafey, 2013, Electrochemical impedance immunosensor based on gold nanoparticles–protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue, Biosens. Bioelectron., 50, 143, 10.1016/j.bios.2013.05.063 · doi:10.1016/j.bios.2013.05.063
- Filip, 2015, Graphene as a signal amplifier for preparation of ultrasensitive electrochemical biosensors, Chem Zvesti, 69, 112
- Llorente, 2019, Electrochemical reduction of graphene oxide on biomedical grade CoCr alloy, Appl. Surf. Sci., 465, 1028, 10.1016/j.apsusc.2018.09.188 · doi:10.1016/j.apsusc.2018.09.188
- Takemura, 2020, Electrochemical detection of white spot syndrome virus with a silicone rubber disposable electrode composed of graphene quantum dots and gold nanoparticle-embedded polyaniline nanowires, J. Nanobiotechnology, 18, 152, 10.1186/s12951-020-00712-4 · doi:10.1186/s12951-020-00712-4
- Ghanavati, 2020, A novel label-free impedimetric immunosensor for sensitive detection of prostate specific antigen using Au nanoparticles/MWCNTs- graphene quantum dots nanocomposite, Microchem. J., 159, 105301, 10.1016/j.microc.2020.105301 · DOI
- Subramanian, 2014, An impedimetric immunosensor based on diamond nanowires decorated with nickel nanoparticles, Analyst, 139, 1726, 10.1039/c3an02045b · doi:10.1039/c3an02045b
- Teimouri, 2019, The highly sensitive impedimetric biosensor in label free approach for hepatitis B virus DNA detection based on tellurium doped ZnO nanowires, Appl. Phys. A, 125, 616, 10.1007/s00339-019-2890-4 · doi:10.1007/s00339-019-2890-4
- Sandil, 2019, Protein-functionalized WO3 nanorods–based impedimetric platform for sensitive and label-free detection of a cardiac biomarker, J. Mater. Res., 34, 1331, 10.1557/jmr.2018.481 · doi:10.1557/jmr.2018.481
- Alfadaly, R.A., Elsayed, A., Hassan, R.Y.A., Noureldeen, A., Darwish, H., and Gebreil, A.S. (2021). Microbial Sensing and Removal of Heavy Metals: Bioelectrochemical Detection and Removal of Chromium(VI) and Cadmium(II). Molecules, 26. · doi:10.3390/molecules26092549
- Fu, 2016, Label-Free Detection of Chondroitin Sulphate Proteoglycan 4 by a Polyaniline/Graphene Nanocomposite Functionalized Impedimetric Immunosensor, J. Nanomater., 2016, 7834657, 10.1155/2016/7834657 · doi:10.1155/2016/7834657
- Abdullah, 2014, PANI-Ag-Cu Nanocomposite Thin Films Based Impedimetric Microbial Sensor for Detection of E. coli Bacteria, J. Nanomater., 2014, 951640, 10.1155/2014/951640 · doi:10.1155/2014/951640
- Fusco, 2017, AuNPs-functionalized PANABA-MWCNTs nanocomposite-based impedimetric immunosensor for 2,4-dichlorophenoxy acetic acid detection, Biosens. Bioelectron., 93, 52, 10.1016/j.bios.2016.10.016 · doi:10.1016/j.bios.2016.10.016
- Zaino, 2016, Nanopore-enabled electrode arrays and ensembles, Microchim. Acta, 183, 1019, 10.1007/s00604-015-1701-7 · doi:10.1007/s00604-015-1701-7
- Hou, 2011, Biomimetic smart nanopores and nanochannels, Chem. Soc. Rev., 40, 2385, 10.1039/c0cs00053a · doi:10.1039/c0cs00053a
- Wu, 2015, Impedance sensing of DNA immobilization and hybridization by microfabricated alumina nanopore membranes, Sens. Actuators B: Chem., 216, 105, 10.1016/j.snb.2015.03.094 · doi:10.1016/j.snb.2015.03.094
- Yang, 2008, Study on the activity and stability of urease immobilized onto nanoporous alumina membranes, Microporous Mesoporous Mater., 111, 359, 10.1016/j.micromeso.2007.08.009 · doi:10.1016/j.micromeso.2007.08.009
- Joung, 2013, A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk, Biosens. Bioelectron., 44, 210, 10.1016/j.bios.2013.01.024 · DOI
- Jin, 2011, A novel porous anodic alumina based capacitive sensor towards trace detection of PCBs, Sens. Actuators B: Chem., 157, 641, 10.1016/j.snb.2011.05.044 · doi:10.1016/j.snb.2011.05.044
- Nagaraj, 2014, Nanochannel-based electrochemical sensor for the detection of pharmaceutical contaminants in water, Environ. Sci. Process. Impacts, 16, 135, 10.1039/C3EM00406F · doi:10.1039/c3em00406f
- Lillo, 2009, Ion-beam pore opening of porous anodic alumina: The formation of single nanopore and nanopore arrays, Mater. Lett., 63, 457, 10.1016/j.matlet.2008.11.007 · doi:10.1016/j.matlet.2008.11.007
- Tan, 2011, A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane, Sens. Actuators B Chem., 159, 328, 10.1016/j.snb.2011.06.074 · doi:10.1016/j.snb.2011.06.074
- Ali, 2013, DNA hybridization detection using less than 10-nm gap silicon nanogap structure, Sens. Actuators A Phys., 199, 304, 10.1016/j.sna.2013.06.008 · doi:10.1016/j.sna.2013.06.008
- Mannoor, 2010, Nanogap Dielectric Spectroscopy for Aptamer-Based Protein Detection, Biophys. J., 98, 724, 10.1016/j.bpj.2009.10.042 · doi:10.1016/j.bpj.2009.10.042
- Okyay, 2017, Using nanogap in label-free impedance based electrical biosensors to overcome electrical double layer effect, Microsyst. Technol., 23, 889, 10.1007/s00542-015-2764-4 · doi:10.1007/s00542-015-2764-4
- Ramnani, 2019, Graphene nanogap electrodes in electrical biosensing, Biosens. Bioelectron., 126, 838, 10.1016/j.bios.2018.11.049 · doi:10.1016/j.bios.2018.11.049
Cited by
Electrochemical Impedance Spectroscopy─A Tutorial
Lazanas, A. C., & Prodromidis, M. I. (2023) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.2c00070 · Cited by 3,123
Impedance Analysis of Electrochemical Systems
Vivier, V., & Orazem, M. E. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00876 · Cited by 615
Current trends in blood biomarker detection and imaging for Alzheimer’s disease
Hu, S., Yang, C., & Luo, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114278 · Cited by 84
Evaluation Method of Internal Resistance for Repurposing Using Middle and Large-Sized Batteries
Lim, M.-G., Jung, J.-B., Kim, N.-H., Kim, J.-M., Shen, J., & Rho, D.-S. (2023) · Energies · doi:10.3390/en16155652 · Cited by 11
Al-Hiyali, M. I., Kannan, R., Alharthi, Y. Z., & Shutari, H. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad7b7a · Cited by 7
Metadata
- Authors
- Magar, H. S., Hassan, R. Y. A., & Mulchandani, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-10-01
- Volume
- 21
- Issue
- 19
- Pages
- 6578
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3202325891
- Cited by
- 1,335
- References
- 65
- FWCI
- 44.93
- Type
- journal article
- Language
- en
- Open access
- gold
- Funders
- National Institute of Justice (2019-NE-BX-006)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.