Abstract

Recent developments in massive machine-type communication (mMTC) scenarios have given rise to never-seen requirements, which triggered the Industry 4.0 revolution. The new scenarios bring even more pressure to comply with the reliability and communication security and enable flawless functionality of the critical infrastructure, e.g., smart grid infrastructure. We discuss typical network grid architecture, communication strategies, and methods for building scalable and high-speed data processing and storage platform. This paper focuses on the data transmissions using the sets of standards IEC 60870-6 (ICCP/TASE.2). The main goal is to introduce the TASE.2 traffic generator and the data collection back-end with the implemented load balancing functionality to understand the limits of current protocols used in the smart grids. To this end, the assessment framework enabling generating and collecting TASE.2 communication with long-term data storage providing high availability and load balancing capabilities was developed. The designed proof-of-concept supports complete cryptographic security and allows users to perform the complex testing and verification of the TASE.2 network nodes configuration. Implemented components were tested in a cloud-based Microsoft Azure environment in four geographically separated locations. The findings from the testing indicate the high performance and scalability of the proposed platform, allowing the proposed generator to be also used for high-speed load testing purposes. The load-balancing performance shows the CPU usage of the load-balancer below 15% while processing 5000 messages per second. This makes it possible to achieve up to a 7-fold improvement of performance resulting in processing up to 35,000 messages per second.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s21206793

Cites

12 of 13 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [7]Savic Novak A.B. Miroslav P. Miodrag T. Implementation of TASE.2, MMS and APLI Protocols Proceedings of the 2008 IEEE International Scientific Conference on Information, Communication and Energy Systems and Technologies (ICEST) Nis, Serbia 25–27 June 2008 670 673

Cited by

Sorted by citations

Authors
Ilgner, P., Cika, P., & Stusek, M.
Affiliations
  • Brno University of Technology (CZ)
  • Department of Telecommunications, Brno University of Technology, 616 00 Brno, Czech Republic
Corresponding author
Ilgner, Petr
Venue
Sensors
Publisher
MDPI AG
Published
2021-10-13
Volume
21
Issue
20
Pages
6793
ISSN
1424-8220 (ISSN-L)
OpenAlex
W3205466899
Cited by
4
References
12
Citations by year
2026: 1 · 2025: 2 · 2023: 1
FWCI
0.07
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Brno University of Technology Digital Library (Brno University of Technology) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Technology Agency of the Czech Republic (TN01000077)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Systems and Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
Keywords
impressed current cathodic protection, SCADA, traffic generator, smart grid communication, load balancing, load testing, cryptographic security, multi-vendor integration, cloud-based testing, Industry 4.0, critical infrastructure
MeSH terms
Communication, Computer Systems, Reproducibility of Results, Information Storage and Retrieval

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review