SCADA-Based Message Generator for Multi-Vendor Smart Grids: Distributed Integration and Verification of TASE.2
Open accessAbstract
Recent developments in massive machine-type communication (mMTC) scenarios have given rise to never-seen requirements, which triggered the Industry 4.0 revolution. The new scenarios bring even more pressure to comply with the reliability and communication security and enable flawless functionality of the critical infrastructure, e.g., smart grid infrastructure. We discuss typical network grid architecture, communication strategies, and methods for building scalable and high-speed data processing and storage platform. This paper focuses on the data transmissions using the sets of standards IEC 60870-6 (ICCP/TASE.2). The main goal is to introduce the TASE.2 traffic generator and the data collection back-end with the implemented load balancing functionality to understand the limits of current protocols used in the smart grids. To this end, the assessment framework enabling generating and collecting TASE.2 communication with long-term data storage providing high availability and load balancing capabilities was developed. The designed proof-of-concept supports complete cryptographic security and allows users to perform the complex testing and verification of the TASE.2 network nodes configuration. Implemented components were tested in a cloud-based Microsoft Azure environment in four geographically separated locations. The findings from the testing indicate the high performance and scalability of the proposed platform, allowing the proposed generator to be also used for high-speed load testing purposes. The load-balancing performance shows the CPU usage of the load-balancer below 15% while processing 5000 messages per second. This makes it possible to achieve up to a 7-fold improvement of performance resulting in processing up to 35,000 messages per second.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
ICCP (TASE.2) is a high-level protocol used for exchanging real-time operational data between utility control centers over WANs.
“The Inter-Control Center Communications Protocol (ICCP), standardized as TASE.2 under IEC 60870-6, is a high-level protocol used for exchanging real-time operational data between utility control centers over wide-area networks (WANs) [29,30].”
From Encryption for Industrial Control Systems: A Survey of Application-Level and Network-Level Approaches in Smart Grids (2026) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Reback, J., McKinney, W., Bossche, J. V. D., Jbrockmendel, Augspurger, T., Cloud, P., Gfyoung, Sinhrks, Klein, A., Tratner, J., et al. (2019) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.3509134 · Cited by 4,025 · see citing works
Govindan, R., Minei, I., Kallahalla, M., Koley, B., & Vahdat, A. M. (2016) · ACM SIGCOMM Conference (SIGCOMM) · doi:10.1145/2934872.2934891 · Cited by 219 · see citing works
Abramova, V., & Bernardino, J. (2013) · doi:10.1145/2494444.2494447 · Cited by 172 · see citing works
Building a replicated logging system with Apache Kafka
Wang, G., Koshy, J., Subramanian, S., Paramasivam, K., Zadeh, M., Narkhede, N., Rao, J., Kreps, J., & Stein, J. (2015) · Proceedings of the VLDB Endowment · doi:10.14778/2824032.2824063 · Cited by 163 · see citing works
Security Challenges in Control Network Protocols: A Survey
Volkova, A., Niedermeier, M., Basmadjian, R., & de Meer, H. (2018) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2872114 · Cited by 118 · see citing works
KAFKA: The modern platform for data management and analysis in big data domain
Shree, R. P. S., Choudhury, T., Gupta, S. C., & Kumar, P. (2017) · 2017 2nd International Conference on Telecommunication and Networks (TEL-NET) · doi:10.1109/tel-net.2017.8343593 · Cited by 51 · see citing works
Load balancing in grid computing: Taxonomy, trends and opportunities
Khan, S., Nazir, B., Khan, I. A., Shamshirband, S., & Chronopoulos, A. T. (2017) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2017.02.013 · Cited by 37 · see citing works
Round-robin Algorithm in HAProxy and Nginx Load Balancing Performance Evaluation: a Review
Pramono, L. H., Buwono, R. C., & Waskito, Y. G. (2018) · International Seminar on Research of Information Technology and Intelligent Systems (ISRITI) · doi:10.1109/isriti.2018.8864455 · Cited by 31 · see citing works
LPWAN Coverage Assessment Planning Without Explicit Knowledge of Base Station Locations
Štůsek, M., Moltchanov, D., Mašek, P., Mikhaylov, K., Hošek, J., Andreev, S. D., Koucheryavy, Y. A., Kustarev, P., Zeman, O., & Roubicek, M. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3102694 · Cited by 18 · see citing works
Stojković, B., & Vukasovic, M. (2006) · IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2006.296282 · Cited by 14 · see citing works
Comparative Analysis of Web Applications using JMeter
Jha, N., & Popli, R. (2017) · International Journal of Advanced Research in Computer Science · doi:10.26483/ijarcs.v8i3.3095 · Cited by 12 · see citing works
Consistency analysis of SCADA data from field power systems
Zhang, Y., Wang, L., Hou, G., & Zhang, H. (2015) · IET International Conference on Advances in Power System Control, Operation and Management (APSCOM) · doi:10.1049/ic.2015.0261 · Cited by 6 · see citing works
Power System Visualisation at Southern African Power Pool
Zimba, S. K., Oosthuyse, C., Chikova, A., & Muringai, C. (2018) · EAI International Conference for Research, Innovation and Development for Africa (ACRID) · doi:10.4108/eai.20-6-2017.2270046 · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [7]Savic Novak A.B. Miroslav P. Miodrag T. Implementation of TASE.2, MMS and APLI Protocols Proceedings of the 2008 IEEE International Scientific Conference on Information, Communication and Energy Systems and Technologies (ICEST) Nis, Serbia 25–27 June 2008 670 673
Cited by
Sorted by citations
Narayanan, M., Hafeez, M. A., & Munir, A. (2026) · Journal of Cybersecurity and Privacy · doi:10.3390/jcp6010011 · Cited by 3 · see citing works
“The Inter-Control Center Communications Protocol (ICCP), standardized as TASE.2 under IEC 60870-6, is a high-level protocol used for exchanging real-time operational data between utility control centers over wide-area networks (WANs) [29,30].”
On Grid Resiliency: Cyber-Physical Detection Tool Evaluated in a Multi-Stage Attack Scenario
Homoud, L. A., Barpanda, N., Goulart, A., Davis, K., & Rice, M. J. (2023) · IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm) · doi:10.1109/smartgridcomm57358.2023.10333970 · Cited by 3 · see citing works
Analysing a multi‐stage cyber threat and its impact on the power system
Homoud, L. A., Barpanda, N., Bobato, V., Goulart, A., Davis, K., & Rice, M. J. (2025) · IET Cyber-Physical Systems Theory & Applications · doi:10.1049/cps2.12107 · Cited by 1 · see citing works
Israel, S., Kunkolienkar, S., Goulart, A., Davis, K., & Overbye, T. J. (2025) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3765621
- Authors
- Ilgner, P., Cika, P., & Stusek, M.
- Affiliations
- Brno University of Technology (CZ)
- Department of Telecommunications, Brno University of Technology, 616 00 Brno, Czech Republic
- Corresponding author
- Ilgner, Petr
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-10-13
- Volume
- 21
- Issue
- 20
- Pages
- 6793
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC8541402
- OpenAlex
- W3205466899
- Cited by
- 4
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 1
- FWCI
- 0.07
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Brno University of Technology Digital Library (Brno University of Technology) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Technology Agency of the Czech Republic (TN01000077)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Systems and Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Keywords
- impressed current cathodic protection, SCADA, traffic generator, smart grid communication, load balancing, load testing, cryptographic security, multi-vendor integration, cloud-based testing, Industry 4.0, critical infrastructure
- MeSH terms
- Communication, Computer Systems, Reproducibility of Results, Information Storage and Retrieval
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review