Sensors and Actuation Technologies in Exoskeletons: A Review
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Exoskeletons are robots that closely interact with humans and that are increasingly used for different purposes, such as rehabilitation, assistance in the activities of daily living (ADLs), performance augmentation or as haptic devices. In the last few decades, the research activity on these robots has grown exponentially, and sensors and actuation technologies are two fundamental research themes for their development. In this review, an in-depth study of the works related to exoskeletons and specifically to these two main aspects is carried out. A preliminary phase investigates the temporal distribution of scientific publications to capture the interest in studying and developing novel ideas, methods or solutions for exoskeleton design, actuation and sensors. The distribution of the works is also analyzed with respect to the device purpose, body part to which the device is dedicated, operation mode and design methods. Subsequently, actuation and sensing solutions for the exoskeletons described by the studies in literature are analyzed in detail, highlighting the main trends in their development and spread. The results are presented with a schematic approach, and cross analyses among taxonomies are also proposed to emphasize emerging peculiarities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437 · cited 2×
“a DC [106]; [107]; [186]; [137]; [240]; [89]; [126]; [118]; [223]; [240]; [78]; [126]; [194]; [200]; [232]; [157]; [53]; [213]; [244]; [150]; [127]; [123]; [180]; [184]; [221]; [186]; [200]; [206]; [51]; [182]; [217]; [124]; [119]; [232]; [160]; [101]; [121]; [150]; [127]; [123]; [131]; [124]; [136]; [52]; [119]; [154…”
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428 · cited 5×
“f torque [62]; [105]; [50]; [105]; [78]; [112]; [176]; [152]; [62];”
InfluentialDevelopment and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335 · cited 5×
“a PAM [108]; [245]; [97] 4; [108]; [147]; [147]; [148]; [97] 4; [111]; [247]; [98]; [125]; [108]; [37]; [101]; [125]; [212]; [98]; [125]; [147];”
InfluentialAn exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159 · cited 8×
“a DC [106]; [118]; [170]; [217]; [138]; [119]; [154]; [25]; [59]; [131]; [141]; [244]; [219]; [79]; [180]; [182]; [184]; [221]; [186]; [223]; [194]; [241]; [124]; [137]; [136]; [227]; [151] 1; [240] 2; [89]; [200]; [232]; [101]; [78]; [233]; [145]; [143]; [150]; [206]; [51]; [106]; [107]; [236]; [237] 3; [209]; [210];…”
BackgroundInfluentialA Soft Exoskeleton for Tremor Suppression Equipped with Flexible Semiactive Actuator
Zahedi, A., Zhang, B., Yi, A., & Zhang, D. (2021) · Soft Robotics · doi:10.1089/soro.2019.0194 · Cited by 57 · cited 5×
“Hussain_2021 [27] x x Sun_2021a [219] x x x x x x x x x x x Hu_2021 [81] x x x x x x x x x x Xiao_2021 [206] x x x x x x x x x x x Liu_2021 [77] x x x x x x x x x x Wang_2021 [109] x x x x x x x x x x Guo_2021 [207] x x x x x x x x x x Li_2021a [51] x x x x x x x x x x Ferrero_2021a [177] x x x x x x x x x x x x x Sus…”
InfluentialDesign of an under-actuated exoskeleton system for walking assist while load carrying
Yu, S. N., Lee, H. D., Lee, S. H., Kim, W. S., Han, J. S., & Han, C. S. (2012) · Advanced Robotics · doi:10.1163/156855311x617506 · Cited by 37 · cited 4×
“EMG Sensors [68]; [216]; [217]; [119]; [218]; [47]; [150]; [182]; [189]; [192] 11; [83]; [128]; [124]; [120]; [37]; [247]; [232]; [101]; [46]; [125]; [122]; [234]; [63]; [129]; [206]; [51] 12; [160]; [121]; [129]; [126];”
Influential
Metadata
- Authors
- Tiboni, M., Borboni, A., Vérité, F., Bregoli, C., & Amici, C.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2022-01-24
- Volume
- 22
- Issue
- 3
- Pages
- 884
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W4213104648
- Cited by
- 184
- References
- 6
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensors and Actuation Technologies in Exoskeletons: A Review. https://app.cochat.ai/papers/10.3390/s22030884
- The paper
- Tiboni, M., Borboni, A., Vérité, F., Bregoli, C., & Amici, C. (2022). Sensors and Actuation Technologies in Exoskeletons: A Review. Sensors. https://doi.org/10.3390/s22030884
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.