Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 10

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Multi-Modal Under-Sensorized Wearable System for Optimal Kinematic and Muscular Tracking of Human Upper Limb Motion

Bonifati, Paolo, Baracca, Marco, Menolotto, Mariangela, Averta, Giuseppe, Bianchi, Matteo · 2023 · Sensors

Abstract

Wearable sensing solutions have emerged as a promising paradigm for monitoring human musculoskeletal state in an unobtrusive way. To increase the deployability of these systems, considerations related to cost reduction and enhanced form factor and wearability tend to discourage the number of sensors in use. In our previous work, we provided a theoretical solution to the problem of jointly reconstructing the entire muscular-kinematic state of the upper limb, when only a limited amount of optimally retrieved sensory data are available. However, the effective implementation of these methods in a physical, under-sensorized wearable has never been attempted before. In this work, we propose to bridge this gap by presenting an under-sensorized system based on inertial measurement units (IMUs) and surface electromyography (sEMG) electrodes for the reconstruction of the upper limb musculoskeletal state, focusing on the minimization of the sensors’ number. We found that, relying on two IMUs only and eight sEMG sensors, we can conjointly reconstruct all 17 degrees of freedom (five joints, twelve muscles) of the upper limb musculoskeletal state, yielding a median normalized RMS error of 8.5% on the non-measured joints and 2.5% on the non-measured muscles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s23073716

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 50

  1. Bai, 2020, Low Cost Inertial Sensors for the Motion Tracking and Orientation Estimation of Human Upper Limbs in Neurological Rehabilitation, IEEE Access, 8, 54254, 10.1109/ACCESS.2020.2981014 · DOI
  2. Worsey, M.T., Espinosa, H.G., Shepherd, J.B., and Thiel, D.V. (2019). Inertial sensors for performance analysis in combat sports: A systematic review. Sports, 7. · DOI
  3. Rana, 2020, Wearable sensors for real-time kinematics analysis in sports: A review, IEEE Sens. J., 21, 1187, 10.1109/JSEN.2020.3019016 · DOI · Paper page
  4. Lasota, 2017, A survey of methods for safe human-robot interaction, Found. Trends Robot., 5, 261, 10.1561/2300000052 · DOI · Paper page
  5. Maurice, 2019, Human movement and ergonomics: An industry-oriented dataset for collaborative robotics, Int. J. Robot. Res., 38, 1529, 10.1177/0278364919882089 · DOI
  6. Ranavolo, A., Ajoudani, A., Cherubini, A., Bianchi, M., Fritzsche, L., Iavicoli, S., Sartori, M., Silvetti, A., Vanderborght, B., and Varrecchia, T. (2020). The Sensor-Based Biomechanical Risk Assessment at the Base of the Need for Revising of Standards for Human Ergonomics. Sensors, 20. · DOI
  7. Shafti, A., Ataka, A., Lazpita, B.U., Shiva, A., Wurdemann, H.A., and Althoefer, K. (2019, January 20–24). Real-time robot-assisted ergonomics. Proceedings of the 2019 International Conference on Robotics and Automation (ICRA), Montreal, QC, Canada. · DOI
  8. Cop, 2021, Unifying system identification and biomechanical formulations for the estimation of muscle, tendon and joint stiffness during human movement, Prog. Biomed. Eng., 3, 033002, 10.1088/2516-1091/ac12c4 · DOI
  9. Holzbaur, 2007, Upper limb muscle volumes in adult subjects, J. Biomech., 40, 742, 10.1016/j.jbiomech.2006.11.011 · DOI · Paper page
  10. Sengupta, A., and Cao, S. (2022). IEEE Transactions on Neural Networks and Learning Systems, IEEE.
  11. Zhao, M., Li, T., Abu Alsheikh, M., Tian, Y., Zhao, H., Torralba, A., and Katabi, D. (2018, January 18–22). Through-wall human pose estimation using radio signals. Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition, Salt Lake City, UT, USA. · DOI · Paper page
  12. Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., and Stricker, D. (2017). Survey of motion tracking methods based on inertial sensors: A focus on upper limb human motion. Sensors, 17. · DOI · Paper page
  13. Kok, M., Hol, J.D., and Schön, T.B. (2017). Using Inertial Sensors for Position and Orientation Estimation. arXiv. · DOI · Paper page
  14. Rampichini, S., Vieira, T.M., Castiglioni, P., and Merati, G. (2020). Complexity analysis of surface electromyography for assessing the myoelectric manifestation of muscle fatigue: A review. Entropy, 22. · DOI
  15. Rocha, 2017, Weighted-cumulated S-EMG muscle fatigue estimator, IEEE J. Biomed. Health Inform., 22, 1854, 10.1109/JBHI.2017.2783849 · doi:10.1109/jbhi.2017.2783849
  16. Jebelli, H., and Lee, S. (2019). Advances in Informatics and Computing in Civil and Construction Engineering, Springer.
  17. Woodward, 2017, Pervasive monitoring of motion and muscle activation: Inertial and mechanomyography fusion, IEEE/ASME Trans. Mechatron., 22, 2022, 10.1109/TMECH.2017.2715163 · DOI
  18. Latash, 2021, One more time about motor (and non-motor) synergies, Exp. Brain Res., 239, 2951, 10.1007/s00221-021-06188-4 · DOI
  19. Zatsiorsky, 2004, Prehension synergies, Exerc. Sport Sci. Rev., 32, 75, 10.1097/00003677-200404000-00007 · doi:10.1097/00003677-200404000-00007
  20. Latash, M.L. (2008). Neurophysiological Basis of Movement, Human Kinetics. · doi:10.1093/acprof:oso/9780195333169.003.0007
  21. Scano, 2019, A comprehensive spatial mapping of muscle synergies in highly variable upper-limb movements of healthy subjects, Front. Physiol., 10, 1231, 10.3389/fphys.2019.01231 · DOI
  22. Averta, 2019, On the time-invariance properties of upper limb synergies, IEEE Trans. Neural Syst. Rehabil. Eng., 27, 1397, 10.1109/TNSRE.2019.2918311 · DOI
  23. Vermeulen, 2020, Lower limb muscle synergies during walking after stroke: A systematic review, Disabil. Rehabil., 42, 2836, 10.1080/09638288.2019.1578421 · DOI
  24. Chvatal, 2012, Voluntary and reactive recruitment of locomotor muscle synergies during perturbed walking, J. Neurosci., 32, 12237, 10.1523/JNEUROSCI.6344-11.2012 · DOI · Paper page
  25. Catalano, 2014, Adaptive synergies for the design and control of the Pisa/IIT SoftHand, Int. J. Robot. Res., 33, 768, 10.1177/0278364913518998 · DOI · Paper page
  26. Ciocarlie, 2009, Hand posture subspaces for dexterous robotic grasping, Int. J. Robot. Res., 28, 851, 10.1177/0278364909105606 · DOI · Paper page
  27. Averta, 2020, Exploiting upper-limb functional principal components for human-like motion generation of anthropomorphic robots, J. Neuroeng. Rehabil., 17, 1, 10.1186/s12984-020-00680-8 · DOI
  28. Ficuciello, F., Palli, G., Melchiorri, C., and Siciliano, B. (2011, January 25–30). Experimental evaluation of postural synergies during reach to grasp with the UB Hand IV. Proceedings of the 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems, San Francisco, CA, USA. · DOI
  29. Bianchi, 2013, Synergy-based hand pose sensing: Reconstruction enhancement, Int. J. Robot. Res., 32, 396, 10.1177/0278364912474078 · DOI
  30. Bianchi, 2013, Synergy-based hand pose sensing: Optimal glove design, Int. J. Robot. Res., 32, 407, 10.1177/0278364912474079 · DOI
  31. Ciotti, S., Battaglia, E., Carbonaro, N., Bicchi, A., Tognetti, A., and Bianchi, M. (2016). A synergy-based optimally designed sensing glove for functional grasp recognition. Sensors, 16. · DOI
  32. Kuismin, 2017, Estimation of covariance and precision matrix, network structure, and a view toward systems biology, Wiley Interdiscip. Rev. Comput. Stat., 9, e1415, 10.1002/wics.1415 · DOI
  33. Averta, 2022, Optimal Reconstruction of Human Motion From Scarce Multimodal Data, IEEE Trans.-Hum.-Mach. Syst., 52, 833, 10.1109/THMS.2022.3163184 · DOI
  34. Ramsay, J.O., Hooker, G., and Graves, S. (2009). Functional Data Analysis with R and MATLAB, Springer Science & Business Media. · DOI · Paper page
  35. Peppoloni, L., Filippeschi, A., Ruffaldi, E., and Avizzano, C.A. (2013). Proceedings of the 2013 IEEE 11th International Symposium on Intelligent Systems and Informatics (SISY), IEEE.
  36. Saito, 2020, Pose estimation by extended Kalman filter using noise covariance matrices based on sensor output, Robomech J., 7, 1, 10.1186/s40648-020-00185-y · doi:10.1186/s40648-020-00185-y
  37. Averta, 2021, U-Limb: A multi-modal, multi-center database on arm motion control in healthy and post-stroke conditions, GigaScience, 10, giab043, 10.1093/gigascience/giab043 · DOI
  38. Müller, M. (2007). Information Retrieval for Music and Motion, Springer. · DOI · Paper page
  39. Tedaldi, D., Pretto, A., and Menegatti, E. (2014). Proceedings of the 2014 IEEE International Conference on Robotics and Automation (ICRA), IEEE.
  40. Vasconcelos, 2011, Geometric approach to strapdown magnetometer calibration in sensor frame, IEEE Trans. Aerosp. Electron. Syst., 47, 1293, 10.1109/TAES.2011.5751259 · DOI · Paper page
  41. Bleser, G., Hendeby, G., and Miezal, M. (2011). Proceedings of the 2011 10th IEEE International Symposium on Mixed and Augmented Reality, IEEE.
  42. Farago, 2022, A Review of Techniques for Surface Electromyography Signal Quality Analysis, IEEE Rev. Biomed. Eng., 16, 472, 10.1109/RBME.2022.3164797 · DOI
  43. Zhao, 2021, Ultra-conformal skin electrodes with synergistically enhanced conductivity for long-time and low-motion artifact epidermal electrophysiology, Nat. Commun., 12, 4880, 10.1038/s41467-021-25152-y · DOI · Paper page
  44. Potvin, 2004, Less is more: High pass filtering, to remove up to 99% of the surface EMG signal power, improves EMG-based biceps brachii muscle force estimates, J. Electromyogr. Kinesiol., 14, 389, 10.1016/j.jelekin.2003.10.005 · DOI · Paper page
  45. McNames, 2015, Human joint angle estimation with inertial sensors and validation with a robot arm, IEEE Trans. Biomed. Eng., 62, 1759, 10.1109/TBME.2015.2403368 · DOI · Paper page
  46. Slade, 2021, An open-source and wearable system for measuring 3D human motion in real-time, IEEE Trans. Biomed. Eng., 69, 678, 10.1109/TBME.2021.3103201 · DOI
  47. Alizadegan, 2017, Shoulder and elbow joint angle estimation for upper limb rehabilitation tasks using low-cost inertial and optical sensors, J. Mech. Med. Biol., 17, 1750031, 10.1142/S0219519417500312 · DOI
  48. Goodfellow, 2020, Generative adversarial networks, Commun. ACM, 63, 139, 10.1145/3422622 · DOI · Paper page
  49. Liu, H., Hartmann, Y., and Schultz, T. (2022, January 9–11). A Practical Wearable Sensor-based Human Activity Recognition Research Pipeline. Proceedings of the 15th International Joint Conference on Biomedical Engineering Systems and Technologies, Online. · DOI
  50. Hartmann, Y., Liu, H., and Schultz, T. (2022, January 21–25). Interactive and Interpretable Online Human Activity Recognition. Proceedings of the 2022 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops), Pisa, Italy. · DOI

Cited by

See all 10

Metadata

Authors
Bonifati, P., Baracca, M., Menolotto, M., Averta, G., & Bianchi, M.
Venue
Sensors
Publisher
MDPI AG
Published
2023-04-03
Volume
23
Issue
7
Pages
3716
ISSN
1424-8220
Cited by
10
References
1
Language
en
Funders
  • European Union’s Horizon 2020 Research and Innovation Program (101017274, 871237, 818 2017SB48FP)
  • TIGHT: Tactile InteGration for Humans and arTificial systems (101017274, 871237, 818 2017SB48FP)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Multi-Modal Under-Sensorized Wearable System for Optimal Kinematic and Muscular Tracking of Human Upper Limb Motion. https://app.cochat.ai/papers/10.3390/s23073716
The paper
Bonifati, P., Baracca, M., Menolotto, M., Averta, G., & Bianchi, M. (2023). A Multi-Modal Under-Sensorized Wearable System for Optimal Kinematic and Muscular Tracking of Human Upper Limb Motion. Sensors. https://doi.org/10.3390/s23073716

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.