The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Human Joint Angle Estimation with Inertial Sensors and Validation with A Robot Arm
Abstract
Traditionally, human movement has been captured primarily by motion capture systems. These systems are costly, require fixed cameras in a controlled environment, and suffer from occlusion. Recently, the availability of low-cost wearable inertial sensors containing accelerometers, gyroscopes, and magnetometers have provided an alternative means to overcome the limitations of motion capture systems. Wearable inertial sensors can be used anywhere, cannot be occluded, and are low cost. Several groups have described algorithms for tracking human joint angles. We previously described a novel approach based on a kinematic arm model and the Unscented Kalman Filter (UKF). Our proposed method used a minimal sensor configuration with one sensor on each segment. This paper reports significant improvements in both the algorithm and the assessment. The new model incorporates gyroscope and accelerometer random drift models, imposes physical constraints on the range of motion for each joint, and uses zero-velocity updates to mitigate the effect of sensor drift. A high-precision industrial robot arm precisely quantifies the performance of the tracker during slow, normal, and fast movements over continuous 15-min recording durations. The agreement between the estimated angles from our algorithm and the high-precision robot arm reference was excellent. On average, the tracker attained an RMS angle error of about 3(°) for all six angles. The UKF performed slightly better than the more common Extended Kalman Filter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311
Bergmann, J. H., Mayagoitia, R. E., & Smith, I. C. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-3 · Cited by 88
Kinematics and Dynamics of Wearable Robots
Forner‐Cordero, A., Pons, J. L., Turowska, E. A., Schiele, A., Baydal‐Bertomeu, J. M., Garrido, D., Mollá, F., Belda‐lois, J. M., Poveda, R., Barberá, R., et al. (2008) · Wearable Robots · doi:10.1002/9780470987667.ch3 · Cited by 24
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263
Rodgers, M. M., Alon, G., Pai, V. M., & Conroy, R. S. (2019) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668319839607 · Cited by 119
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Metadata
- Authors
- El-Gohary, M., & McNames, J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-07
- Volume
- 62
- Issue
- 7
- Pages
- 1759-1767
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2144593983
- Cited by
- 167
- References
- 3
- FWCI
- 24.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Joint Angle Estimation with Inertial Sensors and Validation with A Robot Arm. https://app.cochat.ai/papers/10.1109/tbme.2015.2403368
- The paper
- El-Gohary, M., & McNames, J. (2015). Human Joint Angle Estimation with Inertial Sensors and Validation with A Robot Arm. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2015.2403368
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.