The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index; 41 of the 63 sources its claims cite were checked for support.
Naturalistic Hyperscanning with Wearable Magnetoencephalography
Open accessPublished version of a preprint
Abstract
The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction. However, present technologies are limited, either by poor performance (low spatial/temporal precision) or an unnatural scanning environment (claustrophobic scanners, with interactions via video). Here, we describe hyperscanning using wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs). We demonstrate our approach by simultaneously measuring brain activity in two subjects undertaking two separate tasks-an interactive touching task and a ball game. Despite large and unpredictable subject motion, sensorimotor brain activity was delineated clearly, and the correlation of the envelope of neuronal oscillations between the two subjects was demonstrated. Our results show that unlike existing modalities, OPM-MEG combines high-fidelity data acquisition and a naturalistic setting and thus presents significant potential to investigate neural correlates of social interaction.
Overview
CoChat Summary
TL;DR
This paper reports the first hyperscanning experiments using wearable magnetoencephalography (MEG) based on optically pumped magnetometers (OPMs), with two participants scanned simultaneously during naturalistic tasks. It demonstrates that OPM-MEG can recover sensorimotor beta-band activity and inter-brain oscillatory relationships despite substantial participant motion.
Key findings
- Matrix-coil field nulling reduced remnant fields over the helmets: in the touching task, from 3.3 ± 1.8 nT to 0.48 ± 0.44 nT (factor 6.9) for Participant 1 and from 4.1 ± 2.2 nT to 0.43 ± 0.40 nT (factor 9.5) for Participant 2; in the ball game, from 3.8 ± 2.8 nT to 1.6 ± 1.3 nT (factor 2.4) for Participant 1 and from 5.7 ± 2.9 nT to 2.0 ± 1.2 nT (factor 2.9) for Participant 3.
- Despite motion, beamformer images showed sensorimotor/motor activation and task-induced beta-amplitude reduction. In the touching task, maximum translations were 16 mm and 24 mm and maximum rotations 3.0° and 7.9° for Participants 1 and 2; in the ball game, maximum translations were 50.0 mm and 64.8 mm and maximum rotations 17.0° and 17.4° for Participants 1 and 3.
- In the touching task, the active participant showed beta-power reduction that began earlier and persisted longer than in the passive participant.
- In the ball game, beta envelopes from the two participants evolved in anti-correlation with a lag of ~0.6 s between participants.
Methods
- OPM-MEG system: up to 50 second-generation QuSpin zero-field magnetometers, with 16 OPMs per participant over left sensorimotor cortex in 3D-printed helmets; data sampled at 1200 Hz; participant motion tracked optically at 120 Hz. A 48-channel bi-planar matrix coil system (24 square coils per plane) was used for active field nulling.
- Tasks: a two-person touching task with 30 repetitions (60 trials total) and 5 s inter-trial interval; and a two-person table-tennis ball game with 25 repetitions of 5 s play and 7 s rest, excluding two dropped-ball trials.
- Analysis: linearly constrained minimum variance beamformer, pseudo-T-statistical contrast between active and control windows, time–frequency analysis of beta band (13–30 Hz), virtual electrode reconstruction, and autocorrelation/cross-correlation of beta envelopes.
Limitations
- The paper states that participant movement away from the nulled volumes was deliberately limited, with participants’ feet kept planted, because large field changes from sensor movement through a non-zero field can cause OPM nonlinearities, cross-axis projection errors, sensor gain changes, and reduced neuronal source-modelling accuracy.
- The paper states that extending the dynamic field-control approach to two helmets will be required to enable the full potential of OPM-MEG hyperscanning, and that the presented demonstrations only hint at the possibilities.
- Evident from the text: the experiments used very small samples (two participants per task, with Participant 1 reused across tasks), so no group-level statistical inference is possible; ball-game nulling performance was lower than in the touching task because the larger participant separation meant fewer unit coils contributed to nulling.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
24 Valid · 1 Not valid · 12 Not checked · 33 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“Increased proximity to the scalp can improve sensitivity and spatial resolution beyond that which is achieved using a cryogenic MEG [26,27].”
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 1. Introduction
What the sources say
- Supportedcites [26] Boto, E., Bowtell, R., Krüger, P., Fromhold, T.M., Morris, P.G., Meyer, S.S., Barnes, G.R., and Brookes, M.J. (2016). On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study. PLoS ONE, 11. source
The Abstract reports that sensors closer to the scalp offer increased sensitivity and that a simulated whole-head OPM system improved sensitivity and spatial resolution over a simulated superconducting system. The Results also report better spatial resolution for the simulated OPM system (Fig. 8). The paper cautions that realizing these gains depends on accurate forward models. (LLM, conf=0.93)
- Supportedcites [27] Iivanainen, 2017, Measuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays, Neuroimage source
The Introduction explains that cryogenic insulation keeps SQUID sensors farther from the scalp, while on-scalp sensors can be placed within millimetres. The Conclusions report that simulated on-scalp arrays should substantially improve signal-to-noise ratio and achievable spatial resolution over traditional SQUID arrays. The claim’s “can improve” wording is consistent with that simulation-based finding. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“this results in an environment which offers limited possibilities for experimental design.”
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 1. Introduction
What the sources say
- Supportedcites [4] Renvall, 2020, Imaging Real-Time Tactile Interaction with Two-Person Dual-Coil FMRI, Front. Psychiatry source
The Discussion (Limitations and Future Directions; page not supplied) says the setup limits which social tasks can be studied. The Discussion (Practicality of the Two-Person Imaging Setup; page not supplied) also says visual stimulus projection was deemed impractical and scanning time had to be kept short. These are concrete limits on experimental design in the two-person setup. (LLM, conf=0.89)
- Partly supportedcites [5] Lee, 2012, Decoupled Circular-Polarized Dual-Head Volume Coil Pair for Studying Two Interacting Human Brains with Dyadic FMRI, Magn. Reson. Med. sourceExperimental — accuracy not yet measured
Our copy documents real constraints of scanning two people in one bore — the 50x50x45 cm3 homogeneous B0 ellipsoid that truncates occipital/visual cortex (Coil Structure and Design; The Issue on Shimming), the narrow-bore difficulty accommodating two medium-build adults, and rung-orientation restrictions that 'eliminate the six-rung birdcage as an option' and obstruct facial view (DISCUSSIONS, Trade-off Between Four- and Eight-Rung Birdcages) — and it states that dyadic fMRI 'requires completely new paradigms in experimental design' (Imaging Two People Simultaneously in One Scanner). However, that last statement is tied to the dynamic, asymmetric BOLD patterns between subjects rather than to the scanning environment, and the paper nowhere characterizes the two-person MRI environment as offering 'limited possibilities' for design; on the contrary it presents the DHVC as granting interaction observation 'not possible with any other fMRI technique' (Abstract). The degree/framing of the claim is the citing authors' inference. (LLM, conf=0.70)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, the available functional imaging technology places limitations on experimental design, participant experience and data quality [3].”
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 1. Introduction
What the sources say
- Supportedcites [3] Czeszumski, 2020, Hyperscanning: A Valid Method to Study Neural Inter-Brain Underpinnings of Social Interaction, Front. Hum. Neurosci. source
The Type of Methods sections describe trade-offs in resolution and mobility across imaging technologies. The fMRI section says participants must lie still in a scanner, restricting naturalistic experimental designs; the fNIRS section discusses resolution and susceptibility to motion artifacts. Together, these support the broad claim about limits on design, participant experience, and data quality. Page numbers are unavailable in our copy. (LLM, conf=0.87)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“and is sensitive to artefacts from non-neuronal sources of electrical activity, especially muscles, during participant movement [13].”
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 1. Introduction
What the sources say
- Supportedcites [13] Muthukumaraswamy, 2013, High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations, Front. Hum. Neurosci. source
The section “The characteristics of muscle artifacts in MEG/EEG” says muscle activity can contaminate EEG, including recordings made at rest, and describes contamination produced by intentional contractions. The Recommendations section advises positioning participants comfortably to reduce postural muscle artifacts. Together, these passages support the claim that EEG is sensitive to muscle-related artifacts during participant movement. (LLM, conf=0.91)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“but suffers from poor spatial resolution”
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 1. Introduction
What the sources say
- Supportedcites [9] 2013, EEG and MEG: Relevance to Neuroscience, Neuron source
The Concluding Remarks describe the “limited spatial resolution” of EEG/MEG signals as a shortcoming. Section 2.2 also explains that tissues between the cortex and scalp distort EEG signals. Together, these support the paraphrase that EEG suffers from poor spatial resolution. (LLM, conf=0.92)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
37 more claims · 9 with their cited sources checked
Create a free account to see all 70 claims and to verify the 4 references still open.
- It may state two separate claims as one. 15
- Probably not a substantial claim. 17
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 3. Two-Person Touching Task > 3.1. Methods
“overlapping frequency bands between 1 and 50 Hz”
§ Naturalistic Hyperscanning with Wearable Magnetoencephalography > 3. Two-Person Touching Task > 3.1. Methods
“45–55 Hz”
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328 · cited 1×
“We hypothesised that beta band (13–30 Hz) modulation, as a result of the motor control or sensory response, would be observable in the primary sensorimotor regions [53].”
BackgroundHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274 · cited 2×
“In contrast, functional near-infrared spectroscopy (fNIRS) [8] and electroencephalography (EEG) [9] are wearable technologies that can be deployed in real-life settings [10–12], enabling more naturalistic hyperscanning.”
BackgroundBiodiversity on the Rocks: Macrofauna Inhabiting Authigenic Carbonate at Costa Rica Methane Seeps
Levin, L. A., Mendoza, G. F., Grupe, B. M., Gonzalez, J. P., Jellison, B., Rouse, G., Thurber, A. R., & Waren, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0131080 · Cited by 2,167
Feiner, N., Motone, F., Meyer, A., & Kuraku, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-40055-1 · Cited by 1,987
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 3×
“The f rward f el vector was culated using multi-sph re head model and the current dipole approximation [55].”
MethodFleming, S. M., & Lau, H. C. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00443 · Cited by 1,408
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377 · cited 8×
“This has enabled the recording of brain activity in individual participants undertaking naturalistic tasks (Boto et al., 2018) and exploring virtual reality environments (Roberts et al., 2019), as well as the investigation of cognitive function (Tierney et al., 2018), cerebellar (Lin et al., 2019)…”
BackgroundInfluentialSelf-citationGetting to Know You: Reputation and Trust in a Two-Person Economic Exchange
King-Casas, B., Tomlin, D., Anen, C., Camerer, C. F., Quartz, S. R., & Montague, P. R. (2005) · Science · doi:10.1126/science.1108062 · Cited by 1,345 · cited 2×
“Most fMRI hyperscanning studies [6,7] have used separate scanners connected via video, but this imposes further barriers to natural interaction.”
BackgroundSelf-citation
Cited by
Interference suppression techniques for OPM-based MEG: Opportunities and challenges
Seymour, R. A., Alexander, N., Mellor, S., O’Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118834 · Cited by 138
“Conclusions OPMs are opening up exciting new avenues for MEG research inluding paediatric measurements ( Hill et al., 2019 ), and the adopion of more interactive, naturalistic paradigms involving movement Holmes et al., 2021 ; Roberts et al., 2019 ; Seymour et al., 2021 ).”
InfluentialHakim, U., Felice, S. D., Pinti, P., Zhang, X., Noah, J. A., Ono, Y., Burgess, P. W., Hamilton, A. F. D. C., Hirsch, J., & Tachtsidis, I. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120354 · Cited by 153
A 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Self-citationHow to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
“To further improve shielding performance, active compensation coils may be used, with current state-of-theart solutions even enabling MEG measurements from human subjects in motion within shielded rooms [148].”
BackgroundApplications of OPM-MEG for translational neuroscience: a perspective
Brickwedde, M., Anders, P., Kühn, A. A., Lofredi, R., Holtkamp, M., Kaindl, A. M., Grent-‘t-Jong, T., Krüger, P., Sander, T. H., & Uhlhaas, P. J. (2024) · Translational Psychiatry · doi:10.1038/s41398-024-03047-y · Cited by 72
“OPM-MEG systems could potentially overcome these shortcomings as recently demonstrated [118], which could be harnessed to research the origin of altered social interactions in ASD and other syndromes.”
Background
Metadata
- Authors
- Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., Glover, P., Montague, P. R., Brookes, M. J., & Bowtell, R.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Corresponding author
- Holmes, Niall
- ORCID
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2023-06-09
- Volume
- 23
- Issue
- 12
- Pages
- 5454
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC10304205
- OpenAlex
- W4380082698
- Cited by
- 52
- References
- 59
- Citations by year
- 2026: 12 · 2025: 10 · 2024: 14 · 2023: 8
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, other-oa)
- VTechWorks (Virginia Tech) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Institutes of Health (R01EB028772, EP/T001046/1, EP/V047264/1, 203257/Z/16/Z, 203257/B/16/Z)
- the UK Quantum Technology Hub in Sensing and Timing (R01EB028772, EP/T001046/1, EP/V047264/1, 203257/Z/16/Z, 203257/B/16/Z)
- Healthcare Impact Partnership (R01EB028772, EP/T001046/1, EP/V047264/1, 203257/Z/16/Z, 203257/B/16/Z)
- the UK Engineering and Physical Sciences Research Council (EPSRC) (R01EB028772, EP/T001046/1, EP/V047264/1, 203257/Z/16/Z, 203257/B/16/Z)
- a Wellcome Collaborative Award in Science (R01EB028772, EP/T001046/1, EP/V047264/1, 203257/Z/16/Z, 203257/B/16/Z)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Social Sciences › Psychology › Social Psychology › Action Observation and Synchronization
- Keywords
- hyperscanning, optically pumped magnetometers, social interaction, subject motion, ball games
- MeSH terms
- Wearable Electronic Devices, Brain, Humans, Magnetoencephalography, Functional Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Naturalistic Hyperscanning with Wearable Magnetoencephalography. https://app.cochat.ai/papers/10.3390/s23125454
- The paper
- Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., Glover, P., Montague, P. R., Brookes, M. J., & Bowtell, R. (2023). Naturalistic Hyperscanning with Wearable Magnetoencephalography. Sensors. https://doi.org/10.3390/s23125454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.