Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques
Open accessThe DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
Abstract
Heart diseases remain one of the leading causes of morbidity and mortality worldwide, necessitating innovative diagnostic methods for early detection and intervention. An electrocardiogram (ECG) is a well-known technique for the preliminary diagnosis of heart conditions. However, it can not be used for continuous monitoring due to skin irritation. It is well known that every body organ generates a magnetic field, and the heart generates peak amplitudes of about 10 to 100 pT (measured at a distance of about 3 cm above the chest). This poses challenges to capturing such signals. This paper reviews the different techniques used to capture the heart’s magnetic signals along with their limitations. In addition, this paper provides a comprehensive review of the different approaches that use the heart-generated magnetic field to diagnose several heart diseases. This research reveals two aspects. First, as a noninvasive tool, the use of the heart’s magnetic field signal can lead to more sensitive advanced heart disease diagnosis tools, especially when continuous monitoring is possible and affordable. Second, its current use is limited due to the lack of accurate, affordable, and portable sensing technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 The magnetic fields of different body organs and the devices capable of sensing them [69].](https://figures.cochat.ai/paper-figures/29b20fc88cdd43b8b41061ad6e77b5f8/harnessing-the-hearts-magnetic-field-for-advanced-diagnostic-techniques-figure-2.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Its EMF is generated throughout the cardiac cycle and is mainly attributed to transmembrane Na+, K+, and Ca2+ fluxes during depolarization and repolarization, generating time-varying magnetic signals, detectable by sensitive biosensors, in line with Maxwell’s equations [Figure 1] [22,23,24,25,26].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Field strength is ~1 nT near the myocardium, ~0.1 nT at the body surface, and 10–100 pT a few centimeters above the chest—much weaker than the Earth’s field but far stronger than cortical sources [Figure 1] [20,21,22,23,25,26,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Due to their femtotesla sensitivity and vector-field reconstruction capability, SQUIDs remain essential tools for validating the foundations of the heart’s electromagnetic structure and coherence [20,21,23,25,26].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Both SQUIDs and OPMs are highly sensitive to ambient magnetic interference, thus requiring magnetically shielded rooms or advanced active noise-cancelation systems to achieve sufficient signal-to-noise ratios for reliable isolation of cardiac magnetic signals, limitations that hinder widespread clinical scalability [23,24,25,26,27].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“OPMs on the other hand, like the QZFM series by QuSpin (QuSpin Inc., Louisville, CO, USA), represent a promising, emerging technology that combines near-SQUID sensitivity with room-temperature operation while offering scalability towards wearable and multi-subject recording [25,26,44,45].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [26]
Experimental — accuracy not yet measured
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916 · cited 1×
“• Principle: They are highly sensitive devices used to measure magnetic fields [53].”
BackgroundModern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review
Hussain, S., Mubeen, I., Ullah, N., Shah, S. S. U. D., Khan, B. A., Zahoor, M., Ullah, R., Khan, F. A., & Sultan, M. A. (2022) · BioMed Research International · doi:10.1155/2022/5164970 · Cited by 787 · cited 1×
“In [32], the authors presented a review of the modern diagnostic based on imaging techniques and their risks.”
BackgroundMagnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Pinto-Coelho, L. (2023) · Bioengineering · doi:10.3390/bioengineering10121435 · Cited by 676
AI in diagnostic imaging: Revolutionising accuracy and efficiency
Khalifa, M., & Albadawy, M. (2024) · Computer Methods and Programs in Biomedicine Update · doi:10.1016/j.cmpbup.2024.100146 · Cited by 517
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392 · cited 1×
“The seminal work by Baule and McFee (1963) [39] on the detection of magnetic fields produced by the heart and the brain set the stage for the development of magnetocardiography (MCG) [40].”
BackgroundSQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Magnetoelectrics for magnetic sensor applications: status, challenges and perspectives
Wang, Y., Li, J., & Viehland, D. (2014) · Materials Today · doi:10.1016/j.mattod.2014.05.004 · Cited by 358 · cited 1×
“…applied to ME composites, an electric charge across the piezoelectric phase is induced due to the piezoelectricity that results from the deformation produced by the ferromagnetic component due to the magnetostriction that is transferred to the ferroelectric component via interfacial bonding [74].”
BackgroundArtificial intelligence in clinical medicine: catalyzing a sustainable global healthcare paradigm
Krishnan, G., Singh, S., Pathania, M., Gosavi, S., Abhishek, S., Parchani, A., & Dhar, M. (2023) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2023.1227091 · Cited by 296
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277 · cited 4×
“• Principle: They use the saturation of a ferromagnetic core in an alternating magnetic field to detect changes in the external magnetic field [45–47] and even down to 100 fT/ √ Hz [38,47,48].”
BackgroundMethodInfluentialHigh Sensitivity Magnetometers
(2017) · Smart Sensors, Measurement and Instrumentation · doi:10.1007/978-3-319-34070-8 · Cited by 201
Rene Theophile Hyacinthe Laennec (1781-1826): The Man Behind the Stethoscope
Roguin, A. (2006) · Clinical Medicine & Research · doi:10.3121/cmr.4.3.230 · Cited by 197 · cited 1×
“Diagnosing heart diseases has evolved from using a stethoscope [8] to an ECG [9,10].”
BackgroundRajiah, P. S., François, C. J., & Leiner, T. (2023) · Radiology · doi:10.1148/radiol.223008 · Cited by 186
Willem Einthoven and the Birth of Clinical Electrocardiography a Hundred Years Ago
Barold, S. S. (2003) · Cardiac Electrophysiology Review · doi:10.1023/a:1023667812925 · Cited by 182 · cited 1×
“An ECG is used to record the electrical activity of the heart [11].”
MethodLancellotti, P., Price, S., Edvardsen, T., Cosyns, B., Neskovic, A. N., Dulgheru, R., Flachskampf, F. A., Hassager, C., Pasquet, A., Gargani, L., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu210 · Cited by 182
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 3×
“Requires specialized equipment, such as SQUID sensors, often housed in magnetically shielded rooms [92].”
BackgroundInfluentialECG Interpretation: Clinical Relevance, Challenges, and Advances
Rafie, N., Kashou, A. H., & Noseworthy, P. A. (2021) · Hearts · doi:10.3390/hearts2040039 · Cited by 167 · cited 2×
“Unfortunately, an ECG lacks the sensitivity necessary for accurate diagnosis [6,7].”
BackgroundEpidemiology of cardiovascular disease and its risk factors in Korea
Kim, H. C. (2021) · Global Health & Medicine · doi:10.35772/ghm.2021.01008 · Cited by 145 · cited 1×
“For decades, CVDs have been the leading cause of death worldwide with a significant increase from 12.1 million deaths in 1990 to 17.9 million deaths in 2021 (Figure 1), and 85% of these deaths are due to ischemic heart disease [2,3].”
BackgroundInfluentialHolter Monitoring and Loop Recorders: From Research to Clinical Practice
Galli, A., Ambrosini, F., & Lombardi, F. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.17.2 · Cited by 141 · cited 1×
“Despite these limitations, it remains a crucial component in the evaluation and treatment of cardiac conditions [15,16].”
BackgroundMagnetoelectric Magnetic Field Sensors: A Review
Bichurin, M. I., Петров, Р. В., Sokolov, O. V., Leontiev, V. S., Kuts, V. V., Kiselev, D. A., & Wang, Y. (2021) · Sensors · doi:10.3390/s21186232 · Cited by 136
Fujiwara, K., Oogane, M., Kanno, A., Imada, M., Jono, J., Terauchi, T., Okuno, T., Aritomi, Y., Morikawa, M., Tsuchida, M., et al. (2018) · Applied Physics Express · doi:10.7567/apex.11.023001 · Cited by 133 · cited 1×
“In [63], the authors considered using tunnel magne-toresistance (TMR) sensors that operate at room temperature to measure weak biomagnetic fields.”
BackgroundMagnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array
Wyllie, R., Kauer, M., Smetana, G. S., Wakai, R. T., & Walker, T. G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2619 · Cited by 125 · cited 2×
“Applications: They are used in magnetoencephalography (MEG) [54,55], magne-tocardiography (MCG) [69], and fetal magnetocardiography (MCG) [70].”
BackgroundMethodMagnetocardiography with sensors based on giant magnetoresistance
Pannetier-Lecoeur, M., Parkkonen, L., Sergeeva-Chollet, N., Polovy, H., Fermon, C., & Fowley, C. (2011) · Applied Physics Letters · doi:10.1063/1.3575591 · Cited by 113 · cited 1×
“In [64], the authors used hybrid sensors based on Giant Mag-netoresistance (GMR) to capture the magnetic signatures of the heart’s electrical activity (magnetocardiography) in healthy volunteers.”
MethodCoelho, L. P. (2023) · Preprints.org · doi:10.20944/preprints202311.1366.v1 · Cited by 112
Magnetoelectric magnetic field sensors
Viehland, D., Wuttig, M., McCord, J., & Quandt, E. (2018) · MRS Bulletin · doi:10.1557/mrs.2018.261 · Cited by 102
Magnetically induced electric fields and currents in the circulatory system
Tenforde, T. S. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.003 · Cited by 96 · cited 1×
“The heart generates a weak magnetic field due to the electrical currents flowing during the heart cardiac cycle [34–36].”
BackgroundEvaluation of magnetoelectric sensor systems for cardiological applications
Reermann, J., Durdaut, P., Salzer, S., Demming, T., Piorra, A., Quandt, E., Frey, N., Höft, M., & Schmidt, G. U. (2017) · Measurement · doi:10.1016/j.measurement.2017.09.047 · Cited by 84 · cited 1×
“In [76], the authors discussed using ME sensor systems for cardiological applications.”
BackgroundMagnetocardiography for fetal arrhythmias
Strasburger, J. F., Cheulkar, B., & Wakai, R. T. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.02.035 · Cited by 81
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
The Role of Echocardiography in Heart Failure
Marwick, T. H. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.150433 · Cited by 79 · cited 1×
“However, it also has limitations related to operator dependence, image quality, and measurement variability [18–20].”
BackgroundThe origin of echocardiography: a tribute to Inge Edler.
Singh, S., & Goyal, A. (2007) · PubMed · Cited by 71
YAMADA, S., & YAMAGUCHI, I. (2005) · Internal Medicine · doi:10.2169/internalmedicine.44.1 · Cited by 70 · cited 1×
“It can identify ischemic changes in the heart that might not be apparent in a conventional electrocardiogram (ECG), especially in cases of microvascular dysfunction or in patients with non-obstructive coronary artery disease [79].”
BackgroundBaule, G. M., & McFee, R. (1970) · American Heart Journal · doi:10.1016/0002-8703(70)90312-1 · Cited by 69 · cited 1×
“The heart generates a weak magnetic field due to the electrical currents flowing during the heart cardiac cycle [34–36].”
BackgroundMagnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 68 · cited 2×
“MCG has been shown to have a higher sensitivity in detecting ischemic changes, particularly in patients with non-obstructive coronary artery disease or microvascular dysfunction [80].”
BackgroundMRI and CT in the diagnosis of coronary artery disease: indications and applications
Nikolaou, K., Alkadhi, H., Bamberg, F., Leschka, S., & Wintersperger, B. J. (2010) · Insights into Imaging · doi:10.1007/s13244-010-0049-0 · Cited by 60
Scalp attached tangential magnetoencephalography using tunnel magneto-resistive sensors
Kanno, A., Nakasato, N., Oogane, M., Fujiwara, K., Nakano, T., Arimoto, T., Matsuzaki, H., & Ando, Y. (2022) · Scientific Reports · doi:10.1038/s41598-022-10155-6 · Cited by 60 · cited 1×
“GMR sensors exhibit high sensitivity, making them suitable for detecting weak magnetic fields, which is crucial in medical applications, such as magnetic resonance imaging (MRI) machines [61] and magnetoencephalography (MEG) machines [62].”
BackgroundLow-noise permalloy ring cores for fluxgate magnetometers
Miles, D. M., Ciurzynski, M., Barona, D., Narod, B. B., Bennest, J. R., Kale, A., Lessard, M. R., Milling, D. K., Larson, J., & Mann, I. R. (2019) · Geoscientific instrumentation, methods and data systems · doi:10.5194/gi-8-227-2019 · Cited by 59
The Changing Face of Nuclear Cardiology: Guiding Cardiovascular Care Toward Molecular Medicine
Werner, R. A., Thackeray, J. T., Diekmann, J., Weiberg, D., Bauersachs, J. K., & Bengel, F. M. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.240440 · Cited by 59 · cited 1×
“Although Cardiac MRI and CT scans are more commonly used than Nuclear Cardiology, the latter is evolving toward an interrogation of the biology and molecular pathways [30].”
MethodAtomic magnetometers and their application in industry
Bai, X., Wen, K., Peng, D., Liu, S., & Luo, L. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.1212368 · Cited by 59 · cited 2×
“• Principle: Similar to OPMs, atomic magnetometers measure magnetic fields by detecting the spin precession of atoms induced by magnetic fields [66].”
BackgroundHigh-Sensitivity Low-Noise Miniature Fluxgate Magnetometers Using a Flip Chip Conceptual Design
Lu, C., Huang, J., Chiu, P.-K., Chiu, S.-L., & Jeng, J.-T. (2014) · Sensors · doi:10.3390/s140813815 · Cited by 50 · cited 1×
“They generally consume more power compared to other magnetic field sensors, which can be a drawback for battery-operated medical devices [50].”
BackgroundInvestigation of Converse Magnetoelectric Thin-Film Sensors for Magnetocardiography
Elzenheimer, E., Hayes, P., Thormählen, L., Engelhardt, E., Zaman, A., Quandt, E., Frey, N., Höft, M., & Schmidt, G. U. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3237910 · Cited by 50 · cited 2×
“For example, in [75], the experiments were conducted in a shielded room.”
BackgroundMethodAsch, F. M., Shah, S. B., Rattin, C., Swaminathan, S. V., Fuisz, A., & Lindsay, J. M. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.02.037 · Cited by 49 · cited 1×
“Unfortunately, an ECG lacks the sensitivity necessary for accurate diagnosis [6,7].”
BackgroundThe History of Cardiovascular Magnetic Resonance
Pohost, G. M. (2008) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2008.07.009 · Cited by 49 · cited 1×
“Another technique used for heart diagnosis known as Echocardiography uses ultrasound waves to create images of the heart [17].”
MethodGrimm, W., Glaveris, C., Hoffmann, J., Menz, V., Müller, H., Hufnagel, G., & Maisch, B. (2000) · American Heart Journal · doi:10.1067/mhj.2000.107178 · Cited by 49
Local recording of biological magnetic fields using Giant Magneto Resistance-based micro-probes
Barbieri, F., Trauchessec, V., Caruso, L., Trejo-Rosillo, J., Telenczuk, B., Paul, E., Bal, T., Destexhe, A., Fermon, C., Pannetier-Lecoeur, M., et al. (2016) · Scientific Reports · doi:10.1038/srep39330 · Cited by 46 · cited 1×
“…sensors, particularly those utilizing the Giant Magnetoresistance (GMR) effect, have shown significant promise for medical applications due to their unique properties and advantages [60] and show the application of Giant Magnetoresistance-based micro-probes to record biological magnetic fields.”
BackgroundShaping and Focusing Magnetic Field in the Human Body: State-of-the Art and Promising Technologies
Rotundo, S., Brizi, D., Flori, A., Giovannetti, G., Menichetti, L., & Monorchio, A. (2022) · Sensors · doi:10.3390/s22145132 · Cited by 44 · cited 1×
“Using such fields for diagnostic purposes offers several advantages across various medical applications and provides a unique insight into the body’s internal workings [33].”
BackgroundCardiac magnetic resonance imaging: the future is bright
Seetharam, K., & Lerakis, S. (2019) · F1000Research · doi:10.12688/f1000research.19721.1 · Cited by 43 · cited 1×
“Cardiac MRI uses an artificially generated magnetic field [21] and radio waves to create detailed images of the heart [22].”
BackgroundPractical real-time MEG-based neural interfacing with optically pumped magnetometers
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Van Hulle, M. M., Bowtell, R., & Brookes, M. J. (2021) · BMC Biology · doi:10.1186/s12915-021-01073-6 · Cited by 41 · cited 2×
“• Applications: They are used in neuroimaging and magnetoencephalography (MEG) [54,55], magnetocardiography (MCG), Muscle Activity Monitoring (Mag-netomyography, MMG) [56], and medical imaging (MRI and NMR) [55].”
MethodCOMANI, S., LIBERATI, M., MANTINI, D., GABRIELE, E., BRISINDA, D., DI LUZIO, S., FENICI, R., & LUCA ROMANI, G. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00699.x · Cited by 38
Zahran, S., Mahmoudzadeh, M., Wallois, F., Betrouni, N., Derambure, P., Prado, M. L., Palacios-Laloy, A., & Labyt, É. (2022) · Sensors · doi:10.3390/s22083093 · Cited by 36 · cited 2×
“• Applications: They are used in neuroimaging and magnetoencephalography (MEG) [54,55], magnetocardiography (MCG), Muscle Activity Monitoring (Mag-netomyography, MMG) [56], and medical imaging (MRI and NMR) [55].”
MethodMa, Y., Qiao, Z., Yu, M., Wang, Y., Chen, Y., Luo, G., Yang, P., Lin, Q., Zhao, L., Zhang, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0105945 · Cited by 35 · cited 1×
“They are suitable for measuring the very weak magnetic fields [67,68] associated with the human heart [69].”
BackgroundSpin Exchange Relaxation Free (SERF) Magnetometers
Savukov, I. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_15 · Cited by 35 · cited 1×
“They are suitable for measuring the very weak magnetic fields [67,68] associated with the human heart [69].”
BackgroundFetal magnetocardiogram waveform characteristics
Strand, S. A., Strasburger, J. F., & Wakai, R. T. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab0a2c · Cited by 33
Cardiac CT: Indications and Limitations
Prat, S., Sanz, J., & Garcia, M. J. (2008) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.107.042424 · Cited by 32 · cited 2×
“In addition, some patients experience allergic reactions to these agents [26,27].”
BackgroundDetection techniques of biological and chemical Hall sensors
Fan, H., Wang, J., Feng, Q., Hu, Q., Zuo, S., Nabaei, V., & Heidari, H. (2021) · RSC Advances · doi:10.1039/d0ra10027g · Cited by 31
Parallel Fluxgate Magnetometers
Janošek, M. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_2 · Cited by 30 · cited 1×
“• Principle: They use the saturation of a ferromagnetic core in an alternating magnetic field to detect changes in the external magnetic field [45–47] and even down to 100 fT/ √ Hz [38,47,48].”
BackgroundAbility of magnetocardiography to detect regional dominant frequencies of atrial fibrillation
Yoshida, K., Ogata, K., Inaba, T., Nakazawa, Y., Ito, Y., Yamaguchi, I., Kandori, A., & Aonuma, K. (2015) · Journal of Arrhythmia · doi:10.1016/j.joa.2015.05.003 · Cited by 27 · cited 1×
“High sensitivity to small, intracardiac electrical events [80,85].”
BackgroundKORHONEN, P., VÄÄNÄNEN, H., MÄKIJÄRVI, M., KATILA, T., & TOIVONEN, L. (2001) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2001.00772.x · Cited by 26
Siddiqui, T. A., Chamarti, K. S., Tou, L. C., Demirjian, G. A., Noorani, S., Zink, S., & Umair, M. (2022) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd9100357 · Cited by 24 · cited 1×
“It is not invasive, but some patients feel discomfort when performing it, specifically patients with claustrophobia [23].”
BackgroundAI Aided Noise Processing of Spintronic Based IoT Sensor for Magnetocardiography Application
Mohsen, A. S., Al‐Mahdawi, M., Fouda, M. M., Oogane, M., Ando, Y., & Fadlullah, Z. M. (2020) · International Conference on Communications · doi:10.1109/icc40277.2020.9148617 · Cited by 23 · cited 1×
“Despite challenges such as environmental noise sensitivity and higher costs, on-going research in magnetic sensor technology and noise reduction strategies [94,95] holds promise for making MCG more accessible and practical.”
BackgroundUltra-Sensitive Magnetoelectric Sensors of Magnetic Fields for Biomedical Applications
Turutin, A. V., Kubasov, I. V., Kislyuk, A. M., Kuts, V. V., Malinkovich, M. D., Parkhomenko, Y. N., & Sobolev, N. A. (2022) · Nanobiotechnology Reports · doi:10.1134/s2635167622030223 · Cited by 23 · cited 1×
“Though much weaker than the Earth’s magnetic field [37,38], the heart’s magnetic field can be measured and used to provide diagnostics for heart diseases.”
BackgroundThe benefits of echocardiography in primary care
Potter, A., Pearce, K., & Hilmy, N. (2019) · British Journal of General Practice · doi:10.3399/bjgp19x704513 · Cited by 22 · cited 1×
“However, it also has limitations related to operator dependence, image quality, and measurement variability [18–20].”
BackgroundThe current and future status of nuclear cardiology: a consensus report
Underwood, S. R., Bondt, P. D., Flotats, A., Marcassa, C., Pinto, F. J., Schaefer, W. M., & Verberne, H. J. (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu060 · Cited by 21 · cited 1×
“While Nuclear Cardiology offers an assessment of myocardial perfusion as well as information about the effectiveness of treatment, besides being noninvasive, it comes at a high cost and has limited availability [31].”
BackgroundCardiac computed tomography imaging: a history and some future possibilities
Ritman, E. L. (2003) · Cardiology Clinics · doi:10.1016/s0733-8651(03)00092-4 · Cited by 20 · cited 1×
“It uses X-rays to create detailed images of the heart and its blood vessels [24,25].”
Muscle Fatigue Revisited – Insights From Optically Pumped Magnetometers
Sometti, D., Semeia, L., Chen, H., Dax, J., Kronlage, C., Baek, S., Kirchgässner, M., Romano, A., Heilos, J., Staber, D., et al. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.724755 · Cited by 20 · cited 1×
“• Applications: They are used in neuroimaging and magnetoencephalography (MEG) [54,55], magnetocardiography (MCG), Muscle Activity Monitoring (Mag-netomyography, MMG) [56], and medical imaging (MRI and NMR) [55].”
MethodNourmohammadi, A., Asteraki, M. H., Feiz, S. M. H., & Habibi, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2461432 · Cited by 19
Elrefai, A. L., Sasada, I., & Harada, S. (2015) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2015.2453345 · Cited by 17 · cited 1×
“• Principle: They use the saturation of a ferromagnetic core in an alternating magnetic field to detect changes in the external magnetic field [45–47] and even down to 100 fT/ √ Hz [38,47,48].”
BackgroundXiang, J., Yu, X., Bonnette, S., Anand, M., Riehm, C. D., Schlink, B. R., Diekfuss, J. A., Myer, G. D., & Jiang, Y. (2023) · Brain Sciences · doi:10.3390/brainsci13040663 · Cited by 17
Three-Axis Micofluxgate With a Fluxguide
Jeng, J.-T., Lu, C., Ku, H.-W., Huang, B.-R., Chia, M.-H., & Trinh, X. T. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2903107 · Cited by 16 · cited 1×
“• Principle: They use the saturation of a ferromagnetic core in an alternating magnetic field to detect changes in the external magnetic field [45–47] and even down to 100 fT/ √ Hz [38,47,48].”
BackgroundThe atomic magnetometer: A new era in biomagnetism
Wakai, R. T. (2014) · AIP conference proceedings · doi:10.1063/1.4901359 · Cited by 15 · cited 1×
“Applications: They are used in magnetoencephalography (MEG) [54,55], magne-tocardiography (MCG) [69], and fetal magnetocardiography (MCG) [70].”
MethodNoise-Removal from Spectrally-Similar Signals Using Reservoir Computing for MCG Monitoring
Sakib, S., Fouda, M. M., Al‐Mahdawi, M., Mohsen, A. S., Oogane, M., Ando, Y., & Fadlullah, Z. M. (2021) · International Conference on Communications · doi:10.1109/icc42927.2021.9500993 · Cited by 14 · cited 1×
“Despite challenges such as environmental noise sensitivity and higher costs, on-going research in magnetic sensor technology and noise reduction strategies [94,95] holds promise for making MCG more accessible and practical.”
BackgroundDesign and Optimisation of Elliptical-Shaped Planar Hall Sensor for Biomedical Applications
Uddin, S. M., Sayad, A. A., Chan, J., Skafidas, E. S., & Kwan, P. (2022) · Biosensors · doi:10.3390/bios12020108 · Cited by 14 · cited 1×
“Applications: They are used in magnetic microscopy [41] and Biomedical Applications [42,43] Benefits: Hall effect sensors provide a non-contact high-precision method of measurement, reducing the risk of contamination and wear.”
MethodLimitations of Magnetoresistive Current Sensors in Industrial Electronics Applications
Cubells‐Beltrán, M., Reig, C., Martos, J., Torres, J. D. L. C., & Soret, J. (2011) · Cited by 10
Electromagnetic Induction Imaging with Atomic Magnetometers: Progress and Perspectives
Marmugi, L., & Renzoni, F. (2020) · Applied Sciences · doi:10.3390/app10186370 · Cited by 10
Brisinda, D., Caristo, M. E., & Fenici, R. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/8/002 · Cited by 9 · cited 1×
“Several studies have highlighted the effectiveness of MCG in detecting ischemic heart disease [81].”
BackgroundMagnetocardiography, an introduction
Erne, S. N., & Lehmann, J. (1996) · Springer eBooks · doi:10.1007/978-94-011-5674-5_9 · Cited by 9
Łapicki, A., Sanbonsugi, H., Yamamura, T., Matsushita, N., Abe, M., Narimatsu, H., Handa, H., & Sandhu, A. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.855341 · Cited by 7 · cited 1×
“Applications: They are used in magnetic microscopy [41] and Biomedical Applications [42,43] Benefits: Hall effect sensors provide a non-contact high-precision method of measurement, reducing the risk of contamination and wear.”
MethodFeasibility study on measurement of magnetocardiography (MCG) using fluxgate magnetometer
Sengottuvel, S., Sharma, A., Biswal, D., Khan, P. F., Swain, P. P., Patel, R., & Gireesan, K. (2018) · AIP conference proceedings · doi:10.1063/1.5028788 · Cited by 4 · cited 2×
“Applications: Fluxgate magnetometers can still be used for magnetocardiogra-phy (MCG) [49] measurements under certain conditions.”
BackgroundMethodALL ROADS “LEAD” TO ANAPHYLAXIS: HYPERSENSITIVITY TO ELECTROCARDIOGRAM LEADS
Patel, V., Danish, M. A., & Monteleone, C. A. (2018) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2018.09.258 · Cited by 3 · cited 1×
“Patients also could suffer from an allergy due to the electrodes placed on their skin [13].”
BackgroundDekie, L., & Kleiman, R. (2022) · Therapeutic Innovation & Regulatory Science · doi:10.1007/s43441-022-00405-0 · Cited by 3 · cited 1×
“The electrical signals measured by ECG can sometimes be insufficient to detect all types of heart abnormalities, leading to potential false negatives in some scenarios [93].”
BackgroundAnagnostopoulos, C., & Underwood, S. R. (2012) · Clinical Medicine · doi:10.7861/clinmedicine.12-4-373 · Cited by 3
Magnetic microscopy using Hall effect sensors biased with pulsed currents
Sinimbu, L. I. M., Gutierrez, F. V., Lima, C. D. A., Sommer, R. L., Silva, B. G., Serna, J. D. P., Lima, C. L., Bruno, A. C., & Araújo, J. F. D. F. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.171959 · Cited by 3 · cited 1×
“Applications: They are used in magnetic microscopy [41] and Biomedical Applications [42,43] Benefits: Hall effect sensors provide a non-contact high-precision method of measurement, reducing the risk of contamination and wear.”
MethodWhat are the Limitations of the ECG in Clinical Practice?
West, J., & Simpson, A. G. (2009) · Wiley eBooks · doi:10.1002/9781444303551.ch3 · Cited by 2 · cited 1×
“However, it has limitations [12] in detecting structural heart issues and capturing intermittent events and requires skilled interpretation to avoid misdiagnosis.”
BackgroundMalek, H. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-80915-3.00040-5 · Cited by 2
Utility and Limitations of the Surface ECG
Bayés‐Genís, A., Fiol, M., Bayés‐Genís, A., Baranchuk, A. M., Elosúa, R., & Martínez‐Sellés, M. (2021) · Wiley eBooks · doi:10.1002/9781119536475.ch3 · Cited by 1 · cited 1×
“Diagnosing heart diseases has evolved from using a stethoscope [8] to an ECG [9,10].”
BackgroundProton precession magnetometer
Ayon, A. I. (2018) · Macquarie University · doi:10.25949/19438676 · Cited by 1
Research works printed but not linked: 2
- Mubarik, I.A. (2024, July 25). Holter Monitor, Available online: https://www.ncbi.nlm.nih.gov/books/NBK538203/.
- Plonsey, R. (2007). Bioelectricity: A Quantitative Approach, Springer.
Cited by
Hybrid sensor integration in wearable devices for improved cardiovascular health monitoring
Khan, B., Khan, W., Masrur, M. A., Khalid, R. T., Awais, M., Khan, B., Khoo, B. L., & Abdullah, S. (2025) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2025.100889 · Cited by 36
Tian, K., Zhang, X., Yang, J., Hu, Y., Zhang, A., Xiang, M., Zheng, S., & Liu, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3562994 · Cited by 15
Dejneka, Z., Homa, D., Theis, L., Wang, A., & Pickrell, G. (2025) · Sensors · doi:10.3390/s25030841 · Cited by 9
Flow Rate Estimation Based on Magnetic Particle Detection Using a Miniatured High-Sensitivity OPM
Liu, Y., Huang, B., Li, J., Li, R., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3565069 · Cited by 15
“Every time the heart beats, electrical current flows through the myocardium of the heart [42], producing a magnetic field that is close in amplitude to MPs.”
Yaga, L., Amemiya, M., Natsume, Y., Shibuya, T., & Sasano, T. (2025) · Sensors · doi:10.3390/s25154642 · Cited by 9
“Several studies utilizing induction coils, fluxgate sensors, and scalar OPMs have reported that they do not require magnetic shielding or cooling systems [4,32–34].”
Metadata
- Authors
- Elfouly, T., & Alouani, A.
- Affiliations
- Tennessee Technological University (US)
- Corresponding author
- Elfouly, Tarek
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2024-09-18
- Volume
- 24
- Issue
- 18
- Pages
- 6017
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC11435997
- OpenAlex
- W4402601201
- Semantic Scholar
- ed6fdfc640046866e147f9d8e02716156c043978
- Cited by
- 19
- References
- 82
- Citations by year
- 2026: 10 · 2025: 9
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- cardiac magnetic field, magnetocardiography, heart disease diagnosis, non-invasive cardiac monitoring, continuous cardiac monitoring, electrocardiogram limitations
- MeSH terms
- Electrocardiography, Heart, Heart Diseases, Humans, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.