Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Raman Spectroscopy Cell-based Biosensors

Open access
Notingher, Ioan·2007·Sensors

Abstract

One of the main challenges faced by biodetection systems is the ability to detectand identify a large range of toxins at low concentrations and in short times. Cell-basedbiosensors rely on detecting changes in cell behaviour, metabolism, or induction of celldeath following exposure of live cells to toxic agents. Raman spectroscopy is a powerfultechnique for studying cellular biochemistry. Different toxic chemicals have differenteffects on living cells and induce different time-dependent biochemical changes related tocell death mechanisms. Cellular changes start with membrane receptor signalling leading tocytoplasmic shrinkage and nuclear fragmentation. The potential advantage of Ramanspectroscopy cell-based systems is that they are not engineered to respond specifically to asingle toxic agent but are free to react to many biologically active compounds. Ramanspectroscopy biosensors can also provide additional information from the time-dependentchanges of cellular biochemistry. Since no cell labelling or staining is required, the specifictime dependent biochemical changes in the living cells can be used for the identificationand quantification of the toxic agents. Thus, detection of biochemical changes of cells byRaman spectroscopy could overcome the limitations of other biosensor techniques, withrespect to detection and discrimination of a large range of toxic agents. Furtherdevelopments of this technique may also include integration of cellular microarrays forhigh throughput in vitro toxicological testing of pharmaceuticals and in situ monitoring ofthe growth of engineered tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s7081343

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Research works printed but not linked: 9

  1. Lee, 2003, Monitoring and classification of PAH tocixity using an immobilised bioluminescent bacteria, Biosensensors Bioelectron., 18, 571, 10.1016/S0956-5663(03)00039-3 · DOI
  2. Pancrazio, 2004, Sensitivity of the neuronal network biosensor to environmental threats, J. Toxicol. Env. Heal. A., 67, 809, 10.1080/15287390490428279 · doi:10.1080/15287390490428279
  3. Yang, 2003, Cellular microarrays for chemical sensing, Sensor Mater, 15, 313
  4. Rainina, 1996, The development of a new biosensor based on recombinant E. coli for the direct detection of organophosphorus neurotoxins, Biosens. Bioelectron, 11, 991, 10.1016/0956-5663(96)87658-5 · doi:10.1016/0956-5663(96)87658-5
  5. Long, D.A. (1977). Raman spectroscopy, McGraw-Hill.
  6. Uzunbajakava, 2003, Non resonant Raman imaging of protein distribution in single human cells, Biopolymers, 72, 1, 10.1002/bip.10246 · doi:10.1002/bip.10246
  7. Puppels, 1991, Laser irradiation and Raman spectroscopy of single living cells and chromosomes: sample degradation occurs with 514.5 nm but not with 660 nm laser light, Exp. Cell Res., 195, 361, 10.1016/0014-4827(91)90385-8 · doi:10.1016/0014-4827(91)90385-8
  8. Notingher, 2004, New Detection System for Toxic Agents Based on Continuous Spectroscopic Monitoring of Living Cells, Biosens. Bioelectron, 20, 780, 10.1016/j.bios.2004.04.008 · doi:10.1016/j.bios.2004.04.008
  9. Verrier, 2004, In situ monitoring of cell death using Raman microspectroscopy, Biopolymers, 74, 57, 10.1002/bip.20063 · doi:10.1002/bip.20063

Cited by

See all 345

Metadata

Authors
Notingher, I.
Venue
Sensors
Publisher
MDPI AG
Published
2007-07-26
Volume
7
Issue
8
Pages
1343-1358
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2110489045
Cited by
345
References
32
FWCI
3.36
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Raman Spectroscopy Cell-based Biosensors. https://app.cochat.ai/papers/10.3390/s7081343
The paper
Notingher, I. (2007). Raman Spectroscopy Cell-based Biosensors. Sensors. https://doi.org/10.3390/s7081343

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.