The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Raman Spectroscopy Cell-based Biosensors
Open accessAbstract
One of the main challenges faced by biodetection systems is the ability to detectand identify a large range of toxins at low concentrations and in short times. Cell-basedbiosensors rely on detecting changes in cell behaviour, metabolism, or induction of celldeath following exposure of live cells to toxic agents. Raman spectroscopy is a powerfultechnique for studying cellular biochemistry. Different toxic chemicals have differenteffects on living cells and induce different time-dependent biochemical changes related tocell death mechanisms. Cellular changes start with membrane receptor signalling leading tocytoplasmic shrinkage and nuclear fragmentation. The potential advantage of Ramanspectroscopy cell-based systems is that they are not engineered to respond specifically to asingle toxic agent but are free to react to many biologically active compounds. Ramanspectroscopy biosensors can also provide additional information from the time-dependentchanges of cellular biochemistry. Since no cell labelling or staining is required, the specifictime dependent biochemical changes in the living cells can be used for the identificationand quantification of the toxic agents. Thus, detection of biochemical changes of cells byRaman spectroscopy could overcome the limitations of other biosensor techniques, withrespect to detection and discrimination of a large range of toxic agents. Furtherdevelopments of this technique may also include integration of cellular microarrays forhigh throughput in vitro toxicological testing of pharmaceuticals and in situ monitoring ofthe growth of engineered tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introductory Raman Spectroscopy
(2003) · Elsevier eBooks · doi:10.1016/b978-0-12-254105-6.x5000-8 · Cited by 980
A morphological biosensor for mammalian cells
Giaever, I., & Keese, C. R. (1993) · Nature · doi:10.1038/366591a0 · Cited by 770
Characterization of Photodamage to Escherichia coli in Optical Traps
Neuman, K. C., Chadd, E. H., Liou, G. F., Bergman, K., & Block, S. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77117-1 · Cited by 687
Kneipp, K., Kneipp, H., & Kneipp, J. (2006) · Accounts of Chemical Research · doi:10.1021/ar050107x · Cited by 662
Infrared and Raman Spectroscopy of Biological Materials
Gremlich, H.-U., & Yan, B. (2000) · CRC Press eBooks · doi:10.1201/b16936 · Cited by 531
Handbook of Raman Spectroscopy
Lewis, I. R., & Edwards, H. (2001) · CRC Press eBooks · doi:10.1201/9781420029253 · Cited by 528
A new approach to neural cell culture for long-term studies
Potter, S. M., & DeMarse, T. B. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00412-5 · Cited by 489
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Handbook of raman spectroscopy from the research laboratory to the process line
Lewis, I. R., & Edwards, H. G. M. (2001) · Cited by 468
Tiruppathi, C., Malik, A. B., Del Vecchio, P. J., Keese, C. R., & Giaever, I. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.17.7919 · Cited by 433
Development and Application of Cell-Based Biosensors
Pancrazio, J. J., Whelan, J. P., Borkholder, D. A., Ma, W., & Stenger, D. A. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.225 · Cited by 391
The use of neuronal networks on multielectrode arrays as biosensors
Gross, G. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96931-n · Cited by 373
RAMAN SPECTROSCOPY OF PROTEIN AND NUCLEIC ACID ASSEMBLIES
Thomas, G. J. (1999) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.28.1.1 · Cited by 346
Spectroscopic study of human lung epithelial cells (A549) in culture: Living cells versus dead cells
Notingher, I., Verrier, S., Haque, S., Polak, J. M., & Hench, L. L. (2003) · Biopolymers · doi:10.1002/bip.10378 · Cited by 316
Self-citationDiscrimination between ricin and sulphur mustard toxicity in vitro using Raman spectroscopy
Notingher, I., Green, C., Dyer, C., Perkins, E., Hopkins, N., Lindsay, C., & Hench, L. L. (2004) · Journal of The Royal Society Interface · doi:10.1098/rsif.2004.0008 · Cited by 291
Self-citationResonance Raman spectroscopy of red blood cells using near-infrared laser excitation
Wood, B. R., Caspers, P., Puppels, G. J., Pandiancherri, S., & McNaughton, D. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0881-8 · Cited by 281
Raman microspectroscopy: a noninvasive tool for studies of individual living cells in vitro
Notingher, I., & Hench, L. L. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.2.215 · Cited by 230
Self-citationNan, X., Potma, E. O., & Xie, X. S. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.074534 · Cited by 224
Technological advances in high-throughput screening
Fernandes, P. B. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80089-6 · Cited by 170
Chiappalone, M., Vato, A., Tedesco, M., Marcoli, M., Davide, F., & Martinoia, S. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00041-1 · Cited by 131
Making bio-sense of toxicity: new developments in whole-cell biosensors
Sørensen, S. J., Burmølle, M., & Hansen, L. H. (2006) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2005.12.007 · Cited by 130
Ziegler, C. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051550 · Cited by 120
Neuronal networks for biochemical sensing
Gross, G. W., Rhoades, B. K., & Jordan, R. S. (1992) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(92)80022-p · Cited by 94
In vitro toxicology evaluation of pharmaceuticals using Raman micro‐spectroscopy
Owen, C. A., Selvakumaran, J., Notingher, I., Jell, G., Hench, L. L., & Stevens, M. M. (2006) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20884 · Cited by 89
Self-citationDetection of heavy metal toxicity using cardiac cell-based biosensor
Liu, Q., Cai, H., Xu, Y., Xiao, L., Yang, M., & Wang, P. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.03.005 · Cited by 87
Natarajan, A., Molnár, P., Sieverdes, K., Jamshidi, A., & Hickman, J. J. (2005) · Toxicology in Vitro · doi:10.1016/j.tiv.2005.08.014 · Cited by 79
Zhang, X., Yonzon, C. R., Young, M. A., Stuart, D. A., & Duyne, R. P. V. (2005) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20050009 · Cited by 74
Development of a Whole-Cell-Based Biosensor for Detecting Histamine as a Model Toxin
May, K. M. L., Wang, Y., Bachas, L. G., & Anderson, K. W. (2004) · Analytical Chemistry · doi:10.1021/ac049810+ · Cited by 61
Resonance Raman spectroscopy in malaria research
Wood, B. R., & McNaughton, D. (2006) · Expert Review of Proteomics · doi:10.1586/14789450.3.5.525 · Cited by 58
Lorenzelli, L., Margesin, B., Sergio Martinoia, A., Tedesco, M., & Valle, M. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00040-x · Cited by 56
Evaluation of a high throughput toxicity biosensor and comparison with a Daphnia magna bioassay.
Kim, B., Park, K. S., Kim, S. D., & Gu, M. (2003) · Biosensors & bioelectronics · doi:10.1016/s0956-5663(03)00027-7 · Cited by 45
Chiappalone, M., Vato, A., Tedesco, M., et al. (2003) · Cited by 15
Research works printed but not linked: 9
- Lee, 2003, Monitoring and classification of PAH tocixity using an immobilised bioluminescent bacteria, Biosensensors Bioelectron., 18, 571, 10.1016/S0956-5663(03)00039-3 · DOI
- Pancrazio, 2004, Sensitivity of the neuronal network biosensor to environmental threats, J. Toxicol. Env. Heal. A., 67, 809, 10.1080/15287390490428279 · doi:10.1080/15287390490428279
- Yang, 2003, Cellular microarrays for chemical sensing, Sensor Mater, 15, 313
- Rainina, 1996, The development of a new biosensor based on recombinant E. coli for the direct detection of organophosphorus neurotoxins, Biosens. Bioelectron, 11, 991, 10.1016/0956-5663(96)87658-5 · doi:10.1016/0956-5663(96)87658-5
- Long, D.A. (1977). Raman spectroscopy, McGraw-Hill.
- Uzunbajakava, 2003, Non resonant Raman imaging of protein distribution in single human cells, Biopolymers, 72, 1, 10.1002/bip.10246 · doi:10.1002/bip.10246
- Puppels, 1991, Laser irradiation and Raman spectroscopy of single living cells and chromosomes: sample degradation occurs with 514.5 nm but not with 660 nm laser light, Exp. Cell Res., 195, 361, 10.1016/0014-4827(91)90385-8 · doi:10.1016/0014-4827(91)90385-8
- Notingher, 2004, New Detection System for Toxic Agents Based on Continuous Spectroscopic Monitoring of Living Cells, Biosens. Bioelectron, 20, 780, 10.1016/j.bios.2004.04.008 · doi:10.1016/j.bios.2004.04.008
- Verrier, 2004, In situ monitoring of cell death using Raman microspectroscopy, Biopolymers, 74, 57, 10.1002/bip.20063 · doi:10.1002/bip.20063
Cited by
Raman spectroscopy: Recent advancements, techniques and applications
Das, R. S., & Agrawal, Y. K. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.08.003 · Cited by 773
Zulkifli, S. N., Rahim, H. A., & Lau, W.-J. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.09.078 · Cited by 335
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
“These data support recent reports that Raman spectroscopy can be used to distinguish between live and dead cells, as previously reported using Raman micro-spectroscopy (reviewed in Notingher, 2007).”
ResultRaman microspectroscopy of individual algal cells: Sensing unsaturation of storage lipids in vivo
Samek, O., Jonáš, A., Pilát, Z., Zemánek, P., Nedbal, L., Tříska, J., Kotas, P., & Trtílek, M. (2010) · Sensors · doi:10.3390/s100908635 · Cited by 172
Algal Biomass Analysis by Laser-Based Analytical Techniques—A Review
Pořízka, P., Prochazková, P., Prochazka, D., Sládková, L., Novotný, J., Petrilak, M., Brada, M., Samek, O., Pilát, Z., Zemánek, P., et al. (2014) · Sensors · doi:10.3390/s140917725 · Cited by 61
Metadata
- Authors
- Notingher, I.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2007-07-26
- Volume
- 7
- Issue
- 8
- Pages
- 1343-1358
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2110489045
- Cited by
- 345
- References
- 32
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.