The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Review on Hydrogel-based pH Sensors and Microsensors
Open accessAbstract
Stimuli-responsive hydrogels are materials with great potential for development of active functionalities in fluidics and micro-fluidics. Based on the current state of research on pH sensors, hydrogel sensors are described qualitatively and quantitatively for the first time. The review introduces the physical background of the special properties of stimuli-responsive hydrogels. Following, transducers are described which are able to convert the non-electrical changes of the physical properties of stimuli-responsive hydrogels into an electrical signal. Finally, the specific sensor properties, design rules and general conditions for sensor applications are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermodynamics of High Polymer Solutions
Flory, P. J. (1942) · The Journal of Chemical Physics · doi:10.1063/1.1723621 · Cited by 4,374
Statistical Mechanics of Cross-Linked Polymer Networks II. Swelling
Flory, P. J., & Rehner, J. (1943) · The Journal of Chemical Physics · doi:10.1063/1.1723792 · Cited by 3,865
Statistical Mechanics of Cross-Linked Polymer Networks I. Rubberlike Elasticity
Flory, P. J., & Rehner, J. (1943) · The Journal of Chemical Physics · doi:10.1063/1.1723791 · Cited by 2,421
Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials
Holtz, J. H., & Asher, S. A. (1997) · Nature · doi:10.1038/39834 · Cited by 2,004
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Solutions of Long Chain Compounds
Huggins, M. L. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750930 · Cited by 1,919
Tanaka, T., & Fillmore, D. J. (1979) · The Journal of Chemical Physics · doi:10.1063/1.437602 · Cited by 1,626
Collapse of Gels and the Critical Endpoint
Tanaka, T. (1978) · Physical Review Letters · doi:10.1103/physrevlett.40.820 · Cited by 1,581
Thermodynamics of High Polymer Solutions
Flory, P. J. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750971 · Cited by 1,447
Collapse of Gels in an Electric Field
Tanaka, T., Nishio, I., Sun, S.-T., & Ueno-Nishio, S. (1982) · Science · doi:10.1126/science.218.4571.467 · Cited by 1,296
Phase transition in polymer gels induced by visible light
Suzuki, A., & Tanaka, T. (1990) · Nature · doi:10.1038/346345a0 · Cited by 1,035
Spectrum of light scattered from a viscoelastic gel
Tanaka, T., Hocker, L. O., & Benedek, G. B. (1973) · The Journal of Chemical Physics · doi:10.1063/1.1680734 · Cited by 747
The Vapor Pressure and Heat of Vaporization of N15
Kirshenbaum, I. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750970 · Cited by 684
pH-dependent equilibrium swelling properties of hydrophobic polyelectrolyte copolymer gels
Siegel, R. A., & Firestone, B. A. (1988) · Macromolecules · doi:10.1021/ma00189a021 · Cited by 611
Kinetics of swelling and shrinking of gels
Li, Y., & Tanaka, T. (1990) · The Journal of Chemical Physics · doi:10.1063/1.458148 · Cited by 574
Photonic Crystal Chemical Sensors: pH and Ionic Strength
Lee, K., & Asher, S. A. (2000) · Journal of the American Chemical Society · doi:10.1021/ja002017n · Cited by 569
KUHN, W., HARGITAY, B., KATCHALSKY, A., & EISENBERG, H. (1950) · Nature · doi:10.1038/165514a0 · Cited by 490
Micromechanical cantilever as an ultrasensitive pH microsensor
Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A. (2002) · Applied Physics Letters · doi:10.1063/1.1514825 · Cited by 300
Fast Responsive Crystalline Colloidal Array Photonic Crystal Glucose Sensors
Ben-Moshe, M., Alexeev, V. L., & Asher, S. A. (2006) · Analytical Chemistry · doi:10.1021/ac060643i · Cited by 292
A microfluidic actuator based on thermoresponsive hydrogels
Harmon, M. E., Tang, M., & Frank, C. W. (2003) · Polymer · doi:10.1016/s0032-3861(03)00463-4 · Cited by 261
Stimulus-sensitive hydrogels and their applications in chemical (micro)analysis
van der Linden, H. J., Herber, S., Olthuis, W., & Bergveld, P. (2003) · The Analyst · doi:10.1039/b210140h · Cited by 234
Temperature‐, pH‐, and Magnetic‐Field‐Sensitive Hybrid Microgels
Bhattacharya, S., Eckert, F., Boyko, V., & Pich, A. (2007) · Small · doi:10.1002/smll.200600590 · Cited by 216
Rapid swelling and deswelling of reversible gels of polymeric acids by ionization
Katchalsky, A. (1949) · Experientia · doi:10.1007/bf02172636 · Cited by 208
Yu, C., Mutlu, S., Selvaganapathy, P., Mastrangelo, C. H., Svec, F., & Fréchet, J. M. J. (2003) · Analytical Chemistry · doi:10.1021/ac026455j · Cited by 202
Richter, A., Kuckling, D., Howitz, S., Gehring, T., & Arndt, K. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.817898 · Cited by 187
Self-citationLi, W., Zhao, H., Teasdale, P. R., John, R., & Zhang, S. (2002) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(02)00055-x · Cited by 185
pH-Sensitive Holographic Sensors
Marshall, A. J., Blyth, J., Davidson, C. A. B., & Lowe, C. R. (2003) · Analytical Chemistry · doi:10.1021/ac020730k · Cited by 176
Arndt, K. F., Richter, A., Ludwig, S., Zimmermann, J., Kreßler, J., Kuckling, D., & Adler, H. ‐. (1999) · Acta Polymerica · doi:10.1002/(sici)1521-4044(19991201)50:11/12<383::aid-apol383>3.0.co;2-z · Cited by 163
Self-citationHilt, J. Z., Gupta, A. K., Bashir, R., & Peppas, N. A. (2003) · Biomedical Microdevices · doi:10.1023/a:1025786023595 · Cited by 158
Irie, M., Misumi, Y., & Tanaka, T. (1993) · Polymer · doi:10.1016/0032-3861(93)90160-c · Cited by 144
Microfabricated conductimetric pH sensor
Sheppard, N. F., Lesho, M. J., McNally, P., et al. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(94)01542-p · Cited by 129
Influence of volume phase transition phenomena on the behavior of hydrogel-based valves
Richter, A., Howitz, S., Kuckling, D., & Arndt, K. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.12.014 · Cited by 127
Self-citationKühn, W. (1949) · Cellular and Molecular Life Sciences · doi:10.1007/bf02172635 · Cited by 121
Detection of CrO42- Using a Hydrogel Swelling Microcantilever Sensor
Zhang, Y., Ji, H., Brown, G. M., & Thundat, T. G. (2003) · Analytical Chemistry · doi:10.1021/ac0343026 · Cited by 115
A mass-sensitive pH sensor based on a stimuli-responsive polymer
Ruan, C., Zeng, K., & Grimes, C. A. (2003) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.08.051 · Cited by 105
Sartain, F. K., Yang, X., & Lowe, C. R. (2006) · Analytical Chemistry · doi:10.1021/ac060416g · Cited by 104
Kuckling, D., Hoffmann, J., Plötner, M., Ferse, D., Kretschmer, K., Adler, H. P., Arndt, K., & Reichelt, R. (2003) · Polymer · doi:10.1016/s0032-3861(03)00413-0 · Cited by 96
Self-citationKuckling, D., Richter, A., & Arndt, K. (2003) · Macromolecular Materials and Engineering · doi:10.1002/mame.200390007 · Cited by 95
Self-citationDemonstration of etched cladding fiber Bragg grating-based sensors with hydrogel coating
Liu, X., Zhang, X., Cong, J., Xu, J., & Chen, K. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00605-1 · Cited by 94
Equilibrium and non-equilibrium phase transitions in copolymer polyelectrolyte hydrogels
English, A. E., Tanaka, T., & Edelman, E. R. (1997) · The Journal of Chemical Physics · doi:10.1063/1.474516 · Cited by 85
Constant-Volume Hydrogel Osmometer: A New Device Concept for Miniature Biosensors
Han, I. S., Han, M., Kim, J., Lew, S., Lee, Y. J., Horkay, F., & Magda, J. J. (2002) · Biomacromolecules · doi:10.1021/bm0255894 · Cited by 80
A pH Sensor Based on a Microcantilever Coated with Intelligent Hydrogel
Zhang, Y., Ji, H., Snow, D., Sterling, R., & Brown, G. M. (2004) · Instrumentation Science & Technology · doi:10.1081/ci-120037668 · Cited by 61
A swelling hydrogel-based PCO2 sensor
Herber, S., Olthuis, W., & Bergveld, P. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00121-7 · Cited by 58
Polymer gels that can recognize and recover molecules
Tanaka, T., Wang, C., Pande, V. S., Grosberg, A. Y., English, A. E., Masamune, S., Gold, H., Levy, R., & King, K. (1995) · Faraday Discussions · doi:10.1039/fd9950100201 · Cited by 54
Controlled Double‐Sensitivity of Microgels Applied to Electronically Adjustable Chemostats
Richter, A., Türke, A., & Pich, A. (2007) · Advanced Materials · doi:10.1002/adma.200601989 · Cited by 52
Self-citationDesign of a conductimetric pH microsensor based on reversibly swelling hydrogels
Sheppard, N. F., Tucker, R. C., & Salehi-Had, S. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)80028-a · Cited by 51
Single Fiber-Optic pH Sensor Based on Changes in Reflection Accompanying Polymer Swelling
Shakhsher, Z. M., Seitz, W. R., & Legg, K. D. (1994) · Analytical Chemistry · doi:10.1021/ac00082a021 · Cited by 50
An optical biosensor using a fluorescent, swelling sensing element
McCurley, M. F. (1994) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(94)90015-9 · Cited by 47
Suzuki, H. R., Tokuda, T., & Kobayashi, K. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)01028-0 · Cited by 46
Herber, S., Eijkel, J. C. T., Olthuis, W., Bergveld, P., & van den Berg, A. (2004) · The Journal of Chemical Physics · doi:10.1063/1.1773153 · Cited by 43
Mechanically adjustable chemostats based on stimuli-responsive polymers
Richter, A., Wenzel, J., & Kretschmer, K. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.03.002 · Cited by 38
Self-citationAn optically sensitive membrane for pH based on swellable polymer microspheres in a hydrogel
Rooney, M., & Seitz, W. R. (1999) · Analytical Communications · doi:10.1039/a902183c · Cited by 33
High response smart gels: synthesis and application
Arndt, K. F., Schmidt, T. E., Richter, A., et al. (2004) · Macromolecular Symposia · doi:10.1002/masy.200450323 · Cited by 22
Self-citationRichter, A., Howitz, S., Kuckling, D., Kretschmer, K., & Arndt, K. (2004) · Macromolecular Symposia · doi:10.1002/masy.200450650 · Cited by 15
Self-citation
Cited by
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Design and applications of interpenetrating polymer network hydrogels. A review
Dragan, E. S. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.01.065 · Cited by 992
Design of nanostructures based on aromatic peptide amphiphiles
Fleming, S., & Ulijn, R. V. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00247d · Cited by 840
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
Hydrogel‐Based Flexible Electronics
Hu, L., Chee, P. L., Sugiarto, S., Yu, Y., Shi, C., Yan, R., Yao, Z., Shi, X., Zhi, J., Kai, D., et al. (2023) · Advanced Materials · doi:10.1002/adma.202205326 · Cited by 796
Metadata
- Authors
- Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2008-01-25
- Volume
- 8
- Issue
- 1
- Pages
- 561-581
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2115644711
- Cited by
- 742
- References
- 54
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.