The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Antibody Fragments as Probe in Biosensor Development
Open accessAbstract
Today’s proteomic analyses are generating increasing numbers of biomarkers, making it essential to possess highly specific probes able to recognize those targets. Antibodies are considered to be the first choice as molecular recognition units due to their target specificity and affinity, which make them excellent probes in biosensor development. However several problems such as difficult directional immobilization, unstable behavior, loss of specificity and steric hindrance, may arise from using these large molecules. Luckily, protein engineering techniques offer designed antibody formats suitable for biomarker analysis. Minimization strategies of antibodies into Fab fragments, scFv or even single-domain antibody fragments like VH, VL or VHHs are reviewed. Not only the size of the probe but also other issues like choice of immobilization tag, type of solid support and probe stability are of critical importance in assay development for biosensing. In this respect, multiple approaches to specifically orient and couple antibody fragments in a generic one-step procedure directly on a biosensor substrate are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Naturally occurring antibodies devoid of light chains
Hamers-Casterman, C., Atarhouch, T., Muyldermans, S., Robinson, G., Hammers, C., Songa, E. B., Bendahman, N., & Hammers, R. (1993) · Nature · doi:10.1038/363446a0 · Cited by 3,241
Self-citation
Cited by
Polydopamine—a nature-inspired polymer coating for biomedical science
Lynge, M. E., van der Westen, R., Postma, A., & Städler, B. (2011) · Nanoscale · doi:10.1039/c1nr10969c · Cited by 907
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
Antibody orientation on biosensor surfaces: a minireview
Trilling, A. K., Beekwilder, J., & Zuilhof, H. (2013) · The Analyst · doi:10.1039/c2an36787d · Cited by 466
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Nanotechnology for Early Cancer Detection
Choi, Y.-E., Kwak, J.-W., & Park, J. W. (2010) · Sensors · doi:10.3390/s100100428 · Cited by 329
Metadata
- Authors
- Saerens, D., Huang, L., Bonroy, K., & Muyldermans, S.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2008-08-08
- Volume
- 8
- Issue
- 8
- Pages
- 4669-4686
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2116261011
- Cited by
- 169
- References
- 1
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibody Fragments as Probe in Biosensor Development. https://app.cochat.ai/papers/10.3390/s8084669
- The paper
- Saerens, D., Huang, L., Bonroy, K., & Muyldermans, S. (2008). Antibody Fragments as Probe in Biosensor Development. Sensors. https://doi.org/10.3390/s8084669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.