Quantitation of Ecdysterone and Targeted Analysis of WADA-Prohibited Anabolic Androgen Steroids, Hormones, and Metabolic Modulators in Ecdysterone-Containing Dietary Supplements

Open access

Abstract

The aim of our research was to perform a comprehensive study of ecdysterone (ECD)-containing dietary supplements (DSs). Two analytical methods were optimised according to the expected concentration of the target compounds: quantitation of ECD by liquid chromatography (LC) coupled to diode array detector (DAD), and limit test for 47 World Anti-Doping Agency prohibited by LC coupled with tandem mass spectrometer (MS/MS). For quantitation of ECD, the method was fully validated with outstanding performance characteristics (LOD: 35 µg·g−1, LOQ: 115 µg·g−1, CV% < 5%), resulting in significantly lower LOD and shorter runtime than published previously. For limit tests, a chromatographic method was developed to obtain excellent separation, while MS/MS parameters were optimised to allow the lowest possible reporting limit (RL: 0.6–10 ng·g−1 or mL−1). Twenty-one ecdysterone-containing DSs from ten brands were analysed. In all cases, the measured ECD content was much lower than labelled, and 20% of the samples contained a prohibited substance. The concentration of ecdysterone and contaminations varied randomly from batch to batch. The developed methods help to prevent the use of contaminated or useless DSs.

Overview

CoChat Summary

TL;DR

The paper validates LC-DAD quantitation of ecdysterone (ECD) and an LC-MS/MS limit test for 47 WADA-prohibited S1/S4 substances in ECD-containing dietary supplements. Across 21 products from 10 brands, measured ECD was generally far below label claims and some samples contained prohibited anabolic steroids.

Key findings

  • The LC-DAD ECD method showed LOD 35 µg·g⁻¹, LOQ 115 µg·g⁻¹, linear range 1–50 µg·mL⁻¹, correlation coefficient 0.9999, and CV% < 5%; recoveries were within the 70–130% acceptance range, though one was close to the lowest limit.
  • The LC-MS/MS limit test for 47 WADA-prohibited steroids, hormones, and metabolic modulators achieved reporting limits of 0.6–10 ng·g⁻¹ or mL⁻¹, with selectivity factor α > 1.5 for critical pairs.
  • In 21 ECD-containing supplements from 10 brands, measured ECD was usually much lower than labelled; brand “A” had a CV% > 80% between batches, brand “I” had one batch with no detectable ECD and another at barely more than half its label, and the highest measured ECD was 34.1 mg/capsule in brand “F.”
  • The abstract reports that 20% of samples contained a prohibited substance, while the Results section states 25% of samples contained a WADA S1-class prohibited substance; detected contaminants included 4(5)-androstene-3,17-dione and 1,4-androstene-3,17-dione.

Methods

  • Samples were ECD-containing dietary supplements purchased online or received from the National Food Chain Safety Office (NFCSO), Hungary; 21 products from 10 brands were analysed, and method validation used solid samples (three capsules, one tablet) plus 11 diverse supplement matrices for the limit test.
  • ECD was extracted with methanol, separated on a Kinetex C18 RP column, and quantified by LC-DAD at 254 nm using external calibration over 1–50 µg·mL⁻¹.
  • Prohibited substances were analysed by LC-MS/MS on a triple quadrupole instrument using dynamic MRM; 49 steroids including ECD and an internal standard were separated, with positive ESI for most targets and negative ESI for LGD4033 and ostarine.

Limitations

  • The paper states that one recovery was close to the lowest acceptance limit, presumably due to high herbal content, and recommends performing a recovery study for unknown or complex matrices.
  • The paper notes no correlation between product source (webshop vs. authority) and actual composition, including active compound concentration and contamination.
  • Evident from the text: the abstract and Results section disagree on the proportion of samples containing prohibited substances (20% vs. 25%), and the sample set is limited to 21 products from 10 brands, so broader supplement-market representativeness is not established.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/separations10040242

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 LC-DAD chromatograms of sample (a) 'I1' and (b) 'I2' detected at 254 nm. RT of ECD is 3.88 min. Figure 1. LC-DAD chromatograms of sample ( a ) 'I1' and ( b ) 'I2' detected at 254 nm. RT of ECD is 3.88 min.
Figure 1 LC-DAD chromatograms of sample (a) 'I1' and (b) 'I2' detected at 254 nm. RT of ECD is 3.88 min. Figure 1. LC-DAD chromatograms of sample ( a ) 'I1' and ( b ) 'I2' detected at 254 nm. RT of ECD is 3.88 min.CC-BY · From the PDF
Image 2
CC-BY · From the PDF

Verification

Claims the paper makes

6 Valid · 2 Not valid · 6 Not checked · 41 Own results and interpretations

30 more claims

Create a free account to see all 55 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 11
  • It may state two separate claims as one. 11
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 25 references

Research works printed but not linked: 1

  1. Schänzer, W., Geyer, H., Gotzman, A., and Mareck, U. (2012). Recent Advances in Dope Analysis, Proceedings of the Manfred-Donike-Workshop; 30th Cologne Workshop on Dope Analysis, 26th February to 2nd March 2012, Sport und Buch Strauß.

Cited by

Metadata

Authors
Pálinkás, Z., Békési, D., & Utczás, M.
Affiliations
  • Hungarian University of Sports Science (HU)
  • Semmelweis University (HU)
Corresponding author
Utczás, Margita
Venue
Separations
Publisher
MDPI AG
Published
2023-04-05
Volume
10
Issue
4
Pages
242
ISSN
2297-8739 (ISSN-L)
OpenAlex
W4362608545
Cited by
11
References
25
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 4
FWCI
4.75
Type
journal article
Language
en
Open access
Locations
  • Separations (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Social Sciences › Sociology and Political Science › Doping in Sports
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Life Sciences › Agricultural and Biological Sciences › Animal Science and Zoology › Pharmacological Effects and Assays
Keywords
20-hydroxyecdysone, dietary supplements, anti-doping, limit test, method validation, LC-MS/MS, LC-DAD, supplement contamination, metabolic modulators

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.