CoChat

LSTM-Based Model Predictive Control for Optimal Temperature Set-Point Planning

Open access
Jeon, Byung-Ki, Kim, Eui-Jong · 2021 · Sustainability

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

The growing interest in saving building energy has increasingly motivated studies on model predictive control (MPC), where system operation proceeds according to a planned operation strategy. Data-driven models that perform learning using past operation data of buildings are favorable for MPC applications owing to their fast computation speed. However, it is difficult to apply MPC to buildings with insufficient operation data, as the prediction accuracy varies depending on the data used for learning. To address this, we propose a method that involves generating data through a detailed building energy model and utilizing a long short-term memory (LSTM) network that performs learning using the data as an MPC model. The model was verified through a comparison with the reference model using the same optimization algorithm. In the MPC of the objective function, which is to reduce electrical energy expenditure by optimizing the indoor temperature of the target building, approximately 35% grid energy consumption was reduced compared to a reference case, by increasing self-consumption of photovoltaic (PV) energy and avoiding PV curtailment. Further, the required computation time was reduced to approximately 30%, even including the data generation time for daily learning, thereby confirming the feasibility of the MPC model that employs LSTM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/su13020894

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Operating conditions and corresponding energy consumption. Figure 1. Operating conditions and corresponding energy consumption.
Figure 1 Operating conditions and corresponding energy consumption. Figure 1. Operating conditions and corresponding energy consumption.CC-BY · From the PDF
Figure 2 Schematic of energy systems for case study building. Figure 2. Schematic of energy systems for case study building.
Figure 2 Schematic of energy systems for case study building. Figure 2. Schematic of energy systems for case study building.CC-BY · From the PDF
Image 3
CC-BY · From the PDF
Figure 4 Learning performance: cooling coil energy consumption per area for prediction on 7 August 2020 and 10 August 2020. Figure 4. Learning performance: cooling coil energy consumption per area for prediction on 7 August 2020 and 10 August 2020.
Figure 4 Learning performance: cooling coil energy consumption per area for prediction on 7 August 2020 and 10 August 2020. Figure 4. Learning performance: cooling coil energy consumption per area for prediction on 7 August 2020 and 10 August 2020.CC-BY · From the PDF
Figure 5 Prediction performance: cooling coil energy consumption.
Figure 5 Prediction performance: cooling coil energy consumption.CC-BY · From the PDF
Figure 6 Learning and prediction performance for predicting an entire month of August. Figure 6. Learning and prediction performance for predicting an entire month of August. Figure 6. Learning and prediction performance for predicting an entire month of August.
Figure 6 Learning and prediction performance for predicting an entire month of August. Figure 6. Learning and prediction performance for predicting an entire month of August. Figure 6. Learning and prediction performance for predicting an entire month of August.CC-BY · From the PDF
Figure 7 Comparison of optimized operating results (reference vs. proposed). Figure 7. Comparison of optimized operating results (reference vs. proposed). Figure 7. Comparison of optimized operating results (reference vs. proposed).
Figure 7 Comparison of optimized operating results (reference vs. proposed). Figure 7. Comparison of optimized operating results (reference vs. proposed). Figure 7. Comparison of optimized operating results (reference vs. proposed).CC-BY · From the PDF
Figure 8 Comparison of daily grid energy consumption (reference vs. proposed).
Figure 8 Comparison of daily grid energy consumption (reference vs. proposed).CC-BY · From the PDF
Figure 9 Comparison of optimization results on 11 August 2020. Figure 9. Comparison of optimization results on 11 August 2020.
Figure 9 Comparison of optimization results on 11 August 2020. Figure 9. Comparison of optimization results on 11 August 2020.CC-BY · From the PDF
Figure 10 Comparison of grid energy consumption and simulation run time on 11 August 2020.
Figure 10 Comparison of grid energy consumption and simulation run time on 11 August 2020.CC-BY · From the PDF
Figure 11 Comparison of daily unused PV energy.
Figure 11 Comparison of daily unused PV energy.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 57

Metadata

Authors
Jeon, B.-K., & Kim, E.-J.
Affiliations
Inha University (KR)
Corresponding author
Kim, Eui-Jong
Venue
Sustainability
Publisher
MDPI AG
Published
2021-01-17
Volume
13
Issue
2
Pages
894
ISSN
2071-1050 (ISSN-L)
OpenAlex
W3122065728
Cited by
55
References
46
Citations by year
2026: 10 · 2025: 12 · 2024: 8 · 2023: 11 · 2022: 11 · 2021: 3
FWCI
3.78
Type
journal article
Language
en
Open access
Locations
  • Sustainability (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Korea Institute of Energy Technology Evaluation and Planning (2019271010015D)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
Keywords
model predictive control, long short-term memory networks, building energy management, photovoltaic self-consumption, photovoltaic curtailment, building energy simulation, indoor temperature control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.