The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Comparison of Droplet Digital PCR and qPCR for the Quantification of Shiga Toxin-Producing Escherichia coli in Bovine Feces
Open accessAbstract
Cattle are considered to be the main reservoir for Shiga toxin-producing Escherichia coli (STEC) and are often the direct or indirect source of STEC outbreaks in humans. Accurate measurement of the concentration of shed STEC in cattle feces could be a key answer to questions concerning transmission of STEC, contamination sources and efficiency of treatments at farm level. Infected animals can be identified and the contamination level quantified by real-time quantitative PCR (qPCR), which has its specific limitations. Droplet digital PCR (ddPCR) has been proposed as a method to overcome many of the drawbacks of qPCR. This end-point amplification PCR is capable of absolute quantification independent from any reference material and is less prone to PCR inhibition than qPCR. In this study, the qPCR-based protocol described by Verstraete et al. (2014) for Shiga toxin genes stx1 and stx2 and the intimin gene eae quantification was optimized for ddPCR analysis. The properties of ddPCR and qPCR using two different mastermixes (EMM: TaqMan® Environmental Master Mix 2.0; UMM: TaqMan® Universal PCR Master Mix) were evaluated, using standard curves and both artificial and natural contaminated cattle fecal samples. In addition, the susceptibility of these assays to PCR-inhibitors was investigated. Evaluation of the standard curves and both artificial and natural contaminated cattle fecal samples suggested a very good agreement between qPCR using EMM and ddPCR. Furthermore, similar sensitivities and no PCR inhibition were recorded for both assays. On the other hand, qPCR using UMM was clearly prone to PCR inhibition. In conclusion, the ddPCR technique shows potential for the accurate absolute quantification of STEC on the farms, without relying on standardized reference material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Thereby, ddPCR technology can be used for extremely low-target quantitation from variably contaminated samples where the sample dilution requirements to assure consistent and acceptable reaction efficiency, primer annealing and Cq values for qPCR would likely lead to undetectable target levels11, 15.”
From Droplet Digital PCR versus qPCR for gene expression analysis with low abundant targets: from variable nonsense to publication quality data (2017) · cites this paper as [15]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diarrheagenic Escherichia coli
Nataro, J. P., & Kaper, J. B. (1998) · Clinical Microbiology Reviews · doi:10.1128/cmr.11.1.142 · Cited by 5,006
Genome sequence of enterohaemorrhagic Escherichia coli O157:H7
Perna, N. T., Plunkett, G., Burland, V., Mau, B., Glasner, J. D., Rose, D. J., Mayhew, G. F., Evans, P. S., Gregor, J., Kirkpatrick, H. A., et al. (2001) · Nature · doi:10.1038/35054089 · Cited by 2,055
Absolute quantification by droplet digital PCR versus analog real-time PCR
Hindson, C. M., Chevillet, J. R., Briggs, H. A., Gallichotte, E. N., Ruf, I. K., Hindson, B. J., Vessella, R. L., & Tewari, M. (2013) · Nature Methods · doi:10.1038/nmeth.2633 · Cited by 1,488
Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
Pitfalls of quantitative real-time reverse-transcription polymerase chain reaction.
Bustin, S. A., & Nolan, T. (2004) · PubMed · Cited by 1,041
Publication, E. (2015) · doi:10.2903/j.efsa · Cited by 952
Authority, E. F. S., & European Centre for Disease Prevention and Control (2017) · EFSA Journal · doi:10.2903/j.efsa.2017.5077 · Cited by 833
Baker, M. (2012) · Nature Methods · doi:10.1038/nmeth.2027 · Cited by 524
Highly Precise Measurement of HIV DNA by Droplet Digital PCR
Strain, M. C., Lada, S. M., Luong, T., Rought, S. E., Gianella, S., Terry, V. H., Spina, C. A., Woelk, C. H., & Richman, D. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055943 · Cited by 504
On-Chip, Real-Time, Single-Copy Polymerase Chain Reaction in Picoliter Droplets
Beer, N. R., Hindson, B. J., Wheeler, E. K., Hall, S. B., Rose, K. A., Kennedy, I. M., & Colston, B. W. (2007) · Analytical Chemistry · doi:10.1021/ac701809w · Cited by 358
Cited by
Taylor, S. C., Laperriere, G., & Germain, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-02217-x · Cited by 638
“…ddPCR technology can be used for extremely low-target quantitation from variably contaminated samples where the sample dilution requirements to assure consistent and acceptable reaction efficiency, primer annealing and Cq values for qPCR would likely lead to undetectable target levels 11, 15 .”
MethodDigital PCR—An Emerging Technology with Broad Applications in Microbiology
Salipante, S. J., & Jerome, K. R. (2020) · Clinical Chemistry · doi:10.1373/clinchem.2019.304048 · Cited by 159
Application of digital PCR for public health-related water quality monitoring
Tiwari, A., Ahmed, W., Oikarinen, S., Sherchan, S. P., Heikinheimo, A., Jiang, G., Simpson, S. L., Greaves, J., & Bivins, A. W. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.155663 · Cited by 129
Gao, M., Qiu, T., Sun, Y., & Wang, X. (2018) · Environment International · doi:10.1016/j.envint.2018.04.028 · Cited by 127
Comparison among the Quantification of Bacterial Pathogens by qPCR, dPCR, and Cultural Methods
Ricchi, M., Bertasio, C., Boniotti, M. B., Vicari, N., Russo, S., Tilola, M., Bellotti, M. A., & Bertasi, B. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.01174 · Cited by 88
Metadata
- Authors
- Verhaegen, B., De Reu, K., De Zutter, L., Verstraete, K., Heyndrickx, M., & Van Coillie, E.
- Affiliations
- Ghent University (BE)
- Institute of Agriculture and Fishery Research (ILVO), Technology and Food Science Unit, Brusselsesteenweg 370, Melle 9090, Belgium
- Department of Veterinary Public Health and Food Safety, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, Merelbeke 9820, Belgium
- Instituut voor Landbouw en Visserijonderzoek (BE)
- Venue
- Toxins
- Publisher
- MDPI AG
- Published
- 2016-05-18
- Volume
- 8
- Issue
- 5
- Pages
- 157
- ISSN
- 2072-6651 (ISSN-L)
- PMC
- PMC4885071
- OpenAlex
- W2395860034
- Cited by
- 103
- References
- 28
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 8 · 2023: 12 · 2022: 12 · 2021: 10 · 2020: 10 · 2019: 12 · 2018: 10 · 2017: 6 · 2016: 2
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Toxins (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Universiteit Gent
- Topics
- Life Sciences › Immunology and Microbiology › Microbiology › Escherichia coli research studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- Shiga toxin-producing Escherichia coli, droplet digital PCR, real-time quantitative PCR, cattle feces, stx1, stx2, absolute quantification, PCR inhibition, calibration curve, zoonotic transmission
- MeSH terms
- Animals, Cattle, Feces, Genes, Bacterial, Virulence, Polymerase Chain Reaction, Shiga-Toxigenic Escherichia coli
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Droplet Digital PCR and qPCR for the Quantification of Shiga Toxin-Producing Escherichia coli in Bovine Feces. https://app.cochat.ai/papers/10.3390/toxins8050157
- The paper
- Verhaegen, B., De Reu, K., De Zutter, L., Verstraete, K., Heyndrickx, M., & Van Coillie, E. (2016). Comparison of Droplet Digital PCR and qPCR for the Quantification of Shiga Toxin-Producing Escherichia coli in Bovine Feces. Toxins. https://doi.org/10.3390/toxins8050157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.