Influence of PET reconstruction para meters on the TrueX algorithm: A combined phantom and patient study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: With the increasing use of functional imaging in modern radiotherapy (RT) and the envisaged automated integration of PET into target definition, the need for reliable quantification of PET is growing. Reconstruction algorithms in new PET scanners employ pointspread-function (PSF) based resolution recovery, however, their impact on PET quantification still requires thorough investigation. Patients, material, methods: Measurements were performed on a Siemens PET/CT using an IEC phantom filled with varying activity. Data were reconstructed using the OSEM (Gauss filter) and the PSF TrueX (Gauss and Allpass filter) algorithm with all available products of iterations (i) and subsets (ss). The recovery coeffcient (RC) and threshold defining the real sphere volume were determined for all settings and compared to the clinical standard (4i21ss). PET acquisitions of eight lung patients were reconstructed using all algorithms with 4i21ss. Volume size and tracer uptake were determined with different segmentation methods. Results: The threshold for the TrueX was lower (up to 40%) than for the OSEM. The RC for the different algorithms and filters varied. TrueX was more sensitive to permutations of i and ss and only the RC of the OSEM stabilised with increasing number. For patient scans the difference of the volume and activity between TrueX and OSEM could be reduced by applying an adapted threshold and activity correction. Conclusion: The TrueX algorithm results in excellent diagnostic image quality, however, guidelines for native algorithms have to be extended for PSF based reconstruction methods. For appropriate tumour delineation, for the TrueX a lower threshold than the 42% recommended for the OSEM is necessary. These filter dependent thresholds have to be verified for different scanners prior to using them in multicenter trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536 · cited 16×
“The measured PSF was implemented into the system matrix that accounts for detector response depending on the location in the acquisition ring and thus represents the response function of the whole apparatus.”
MethodInfluentialImage-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142 · cited 1×
“pointspread-function (PSF) algorithms into today’s state-of-the-art PET/CT scanners (5, 17, 25), which became the standard in diagnostic clinical routine (30).”
Cited by
Rogasch, J. M., Hofheinz, F., Lougovski, A., Furth, C., Ruf, J., Großer, O. S., Mohnike, K., Hass, P., Walke, M., Amthauer, H., et al. (2014) · EJNMMI Physics · doi:10.1186/2197-7364-1-12 · Cited by 53
Rogasch, J. M., Steffen, I. G., Hofheinz, F., Großer, O. S., Furth, C., Mohnike, K., Hass, P., Walke, M., Apostolova, I., & Amthauer, H. (2015) · EJNMMI Research · doi:10.1186/s13550-015-0111-5 · Cited by 43
Moving the goalposts while scoring―the dilemma posed by new PET technologies
Rogasch, J. M. M., Boellaard, R., Pike, L., Borchmann, P., Johnson, P., Wolf, J., Barrington, S. F., & Kobe, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05403-2 · Cited by 20
Metadata
- Authors
- Rausch, I. F., Bergmann, H., Dudczak, R., Hirtl, A., Georg, D., & Knäusl, B.
- Venue
- Nuklearmedizin
- Publisher
- Georg Thieme Verlag KG
- Published
- 2013
- Volume
- 52
- Issue
- 01
- Pages
- 28-35
- ISSN
- 0029-5566 (ISSN-L)
- 2567-6407
- OpenAlex
- W2275867922
- Cited by
- 35
- References
- 3
- FWCI
- 3.09
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.