CoChat

The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight F18-FDG-PET/CT reconstruction in colorectal liver metastases

Open access

The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The maximum standardized uptake value (SUVmax) is a common clinical parameter for quantification in F18-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT), but it is influenced by image reconstruction. The aim of this study was to analyze the association of SUVmax deviations related to point spread function (PSF) and time-of-flight (TOF) reconstruction with tumor-to-background ratios (TBR) in colorectal liver metastases (CRLM). METHODS: Fifteen patients (f, 6; m, 9; median age, 59 years; range, 32 to 72 years) with 28 liver metastases were included retrospectively. FDG-PET/CT imaging (median activity, 237 MBq; range, 231 to 252 MBq; median uptake, 61 min; range, 55 to 67 min) was performed on a Siemens Biograph mCT 64 followed by image reconstruction using 3D-ordered subset expectation maximization (3D-OSEM) or 3D-OSEM with PSF modeling - both with and without TOF information. Differences in SUVmax were analyzed using the Friedman test and Wilcoxon test for paired non-parametric data. The correlation of inter-method differences with the lesions' TBR was studied using Spearman's rank correlation coefficient (rho). Differences between lesions with low (<4.8) and high (>4.8) TBR were analyzed using the Mann-Whitney U test (TBR measured with 3D-OSEM; binarized by its median). RESULTS: There was a significant correlation of the lesions' TBR with relative SUVmax differences related to PSF (PSF + TOF vs. 3D-OSEM + TOF, rho = 0.61; PSF vs. 3D-OSEM, rho = 0.52) or TOF (PSF + TOF vs. PSF, rho = -0.58; 3D-OSEM + TOF vs. 3D-OSEM, rho = -0.61). Accordingly, PSF algorithms only showed higher SUVmax than non-PSF algorithms in lesions with a high TBR (median differences at low/high TBR, +2.6%/+9.1% [PSF + TOF vs. 3D-OSEM + TOF]; +0.7%/+6.4% [PSF vs. 3D-OSEM]). TOF integration also led to higher SUVmax but mainly at low TBR (low/high TBR, +10.4%/+1.8% [PSF + TOF vs. PSF]; +8.6%/-0.1% [3D-OSEM + TOF vs. 3D-OSEM]). CONCLUSIONS: Both PSF and TOF reconstruction resulted in a substantial alteration of SUVmax in CRLM. TOF provided the highest SUVmax increase in low-contrast lesions while - vice versa - PSF showed the most relevant increase in high-contrast lesions. Thus, one should be aware that quantitative analyses of lesions with varying TBR, e.g., in radiotherapy or follow-up studies, may be mainly affected by either PSF or TOF reconstruction, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13550-015-0111-5

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Relative SUVmax differences between reconstruction algorithms. Box plots of relative SUVmax differences in lesions with low TBR and high TBR. Comparison of PSF vs. non-PSF (upper row) as well as TOF vs. non-TOF algorithms (lower row). Outliers are marked as circles.
Figure 1 Relative SUVmax differences between reconstruction algorithms. Box plots of relative SUVmax differences in lesions with low TBR and high TBR. Comparison of PSF vs. non-PSF (upper row) as well as TOF vs. non-TOF algorithms (lower row). Outliers are marked as circles.CC BY · PubMed Central
Figure 2 Representative examples of lesions with high and low TBR. This figure displays the axial FDG-PET images (jet color table) of a lesion with high TBR (A; TBR, 11.4; volume, 10.0 ml) and a lesion with low TBR (B; TBR, 3.6; volume, 7.9 ml) for all analyzed reconstruction algorithms. The windowing level was the same for all differently reconstructed data (but different between A and B). At high contrast (A), the SUVmax is mainly increased by PSF integration (+22% and +25%) and marginally affected by TOF (+0.2% and +2%). At low contrast (B), the opposite is true (PSF, +3% and +4%; TOF, +15% and +16%).
Figure 2 Representative examples of lesions with high and low TBR. This figure displays the axial FDG-PET images (jet color table) of a lesion with high TBR (A; TBR, 11.4; volume, 10.0 ml) and a lesion with low TBR (B; TBR, 3.6; volume, 7.9 ml) for all analyzed reconstruction algorithms. The windowing level was the same for all differently reconstructed data (but different between A and B). At high contrast (A), the SUVmax is mainly increased by PSF integration (+22% and +25%) and marginally affected by TOF (+0.2% and +2%). At low contrast (B), the opposite is true (PSF, +3% and +4%; TOF, +15% and +16%).CC BY · PubMed Central
Figure 3 Correlation of relative SUVmax differences with the TBR. Correlation plots of relative SUVmax differences and the lesions’ TBR between corresponding PSF and non-PSF algorithms (upper row) or TOF and non-TOF algorithms (lower row), respectively. The solid and dashed lines represent mean ± two standard deviations.
Figure 3 Correlation of relative SUVmax differences with the TBR. Correlation plots of relative SUVmax differences and the lesions’ TBR between corresponding PSF and non-PSF algorithms (upper row) or TOF and non-TOF algorithms (lower row), respectively. The solid and dashed lines represent mean ± two standard deviations.CC BY · PubMed Central
Figure 4 Interaction plots between the TBR and the lesion volume. Interaction plots of the lesions’ TBR and the lesion volume on relative SUVmax differences between corresponding PSF and non-PSF algorithms (upper row) or TOF and non-TOF algorithms (lower row), respectively. The TBR and the lesion volume were binarized by their respective median value. In general, an increased effect of the TBR on SUVmax differences is observed in smaller lesions. This interaction between TBR and lesion volume is indicated by non-parallel courses of corresponding gray and black dashed lines.
Figure 4 Interaction plots between the TBR and the lesion volume. Interaction plots of the lesions’ TBR and the lesion volume on relative SUVmax differences between corresponding PSF and non-PSF algorithms (upper row) or TOF and non-TOF algorithms (lower row), respectively. The TBR and the lesion volume were binarized by their respective median value. In general, an increased effect of the TBR on SUVmax differences is observed in smaller lesions. This interaction between TBR and lesion volume is indicated by non-parallel courses of corresponding gray and black dashed lines.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 49

Metadata

Authors
Rogasch, J. M., Steffen, I. G., Hofheinz, F., Großer, O. S., Furth, C., Mohnike, K., Hass, P., Walke, M., Apostolova, I., & Amthauer, H.
Affiliations
  • University Hospital Magdeburg (DE)
  • Helmholtz-Zentrum Dresden-Rossendorf (DE)
  • Universitätsklinik für Strahlentherapie (DE)
Corresponding author
Rogasch, Julian MM
Venue
EJNMMI Research
Published
2015-05-06
Volume
5
Issue
1
Pages
31-31
ISSN
2191-219X (ISSN-L)
OpenAlex
W2161132469
Cited by
43
References
27
Citations by year
2026: 4 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 2 · 2021: 8 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 2
FWCI
1.62
Type
journal article
Language
en
Open access
Locations
  • EJNMMI Research (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
colorectal liver metastases, tumor-to-background ratio, point spread function, time-of-flight reconstruction, 3D-OSEM, PET attenuation correction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight F18-FDG-PET/CT reconstruction in colorectal liver metastases. https://app.cochat.ai/papers/10.1186/s13550-015-0111-5
The paper
Rogasch, J. M., Steffen, I. G., Hofheinz, F., Großer, O. S., Furth, C., Mohnike, K., Hass, P., Walke, M., Apostolova, I., & Amthauer, H. (2015). The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight F18-FDG-PET/CT reconstruction in colorectal liver metastases. EJNMMI Research. https://doi.org/10.1186/s13550-015-0111-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.