The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Post-Occupancy Evaluation: An Inevitable Step Toward Sustainability
Abstract
Post-occupancy evaluation (POE) is a platform for the systematic study of buildings once occupied, so that lessons may be learned that will improve their current conditions and guide the design of future buildings. Various aspects of the occupied buildings’ functioning and performance can be assessed in a POE, both chemo-physical (indoor environment quality (IEQ), indoor air quality (IAQ) and thermal performance) as well as more subjective and interactional (space use, user satisfaction, etc.). POE draws on an extensive quantitative and qualitative toolkit: measurements and monitoring, on the one hand, and methods such as walk-throughs, observations and user satisfaction questionnaires on the other. POE may seem a necessary, indeed, axiomatic phase of the design and construction process, and exactly the kind of integrated assessment essential for the design of more sustainable buildings. Yet POE researchers have often been regarded with suspicion and even hostility, since their work may cause friction between different stakeholders. This chapter reviews material published in recent years in an attempt to trace the emergence of POE, describe its conceptual and methodological backdrop, its interaction with other issues related to sustainable design, and its increasing ‘canonization’ as a method. We argue that POE offers the potential to integrate a range of fragmented aspects of the construction process and of the relations of buildings to their environment and users. We propose that the acceptance of POE as a mandatory step in the design and commissioning of buildings, whose results are habitually fed backward and forward to other stages of the design and construction processes, is an important and probably inevitable step toward making buildings more sustainable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
International Journal of Physical Sciences
(2025) · International Journal of the Physical Sciences · doi:10.5897/ijps · Cited by 1,932
Adaptive thermal comfort and sustainable thermal standards for buildings
Nicol, J. F., & Humphreys, M. A. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00006-3 · Cited by 1,850
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Productivity in buildings: the ‘killer’ variables
Leaman, A., & Bordass, B. (1999) · Building Research & Information · doi:10.1080/096132199369615 · Cited by 369
Post‐occupancy evaluation: how to make buildings work better
Preiser, W. (1995) · Facilities · doi:10.1108/02632779510097787 · Cited by 368
Assessing Building Performance
(2006) · Routledge eBooks · doi:10.4324/9780080455228 · Cited by 362
A life-cycle energy analysis of building materials in the Negev desert
Huberman, N., & Pearlmutter, D. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.06.002 · Cited by 346
Wagner, A., Gossauer, E., Moosmann, C., Gropp, T., & Leonhart, R. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.013 · Cited by 343
Listening to the occupants: a Web-based indoor environmental quality survey
Zagreus, L., Huizenga, C., Arens, E., & Lehrer, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00301.x · Cited by 294
Occupant satisfaction with indoor environmental quality in green buildings
Abbaszadeh, S., Zagreus, L., Lehrer, D., et al. (2006) · eScholarship (California Digital Library) · Cited by 288
Proceedings of the 8th International Conference on Indoor Air Quality and Climate
Santos, A. M. B., & Gunnarsen, L. (1999) · Indoor Air · Cited by 274
Adapting buildings and cities for climate change: a 21st century survival guide
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0117 · Cited by 235
Assessing Building Performance
(2005) · Structural Survey · doi:10.1108/ss.2005.11023bae.004 · Cited by 177
Thermal comfort and building design in the tropical climates
Mallick, F. H. (1996) · Energy and Buildings · doi:10.1016/0378-7788(95)00940-x · Cited by 168
Ochoa, C. E., & Capeluto, I. G. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.05.001 · Cited by 117
Thermal sensation and comfort with different task conditioning systems
Amai, H., Tanabe, S., AKIMOTO, T., & Genma, T. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.07.043 · Cited by 107
Refining the use of evaporation in an experimental down-draft cool tower
Pearlmutter, D., Erell, E., Etzion, Y., Meir, I. A., & Hu, D. (1996) · Energy and Buildings · doi:10.1016/0378-7788(95)00944-2 · Cited by 102
Self-citationComparison of low-energy office buildings in summer using different thermal comfort criteria
Pfafferott, J., Herkel, S., Kalz, D. E., & Zeuschner, A. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.02.005 · Cited by 100
Menzies, G. F., & Wherrett, J. R. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.09.012 · Cited by 96
Review of Building Quality Using Post Occupancy Evaluation
Watson, C. (2003) · PEB exchange · doi:10.1787/715204518780 · Cited by 79
Atif, M. R., & Galasiu, A. D. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00142-1 · Cited by 68
Review on visual comfort in office buildings and influence of daylight in productivity
Carli, M. D., Giuli, D., & Zecchin, R. (2008) · Padua Research Archive (University of Padova) · Cited by 33
Perceived conditions of workers in different organizational settings
Langston, C., Song, Y., & Purdey, B. (2008) · Facilities · doi:10.1108/02632770810840309 · Cited by 21
McMullen, S. (2007) · Roger Williams University - Digital Commons (Roger Williams University) · Cited by 3
Pati, D., & Augenbroe, G. (2006) · African Journal of Physics · doi:10.5897/ijps.9000378 · Cited by 2
Cited by
The impact of thermal environment on occupant IEQ perception and productivity
Geng, Y., Ji, W., Lin, B., & Zhu, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.022 · Cited by 388
Geng, Y., Ji, W., Wang, Z., Lin, B., & Zhu, Y. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.11.017 · Cited by 324
Postoccupancy evaluations in zoological settings
Kelling, A. S., & Gaalema, D. E. (2011) · Zoo Biology · doi:10.1002/zoo.20398 · Cited by 26
Metadata
- Authors
- Meir, I. A., Garb, Y., Jiao, D., & Cicelsky, A.
- Venue
- Advances in Building Energy Research
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 3
- Issue
- 1
- Pages
- 189-219
- ISSN
- 1751-2549 (ISSN-L)
- 1756-2201
- OpenAlex
- W2125247113
- Cited by
- 256
- References
- 27
- FWCI
- 18.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.