CoChat

Rapid Variability of Sgr A* across the Electromagnetic Spectrum

Open access
Witzel, G., Martinez, G., Willner, S. P., Becklin, E. E., Boyce, H., Do, T., Eckart, A., Fazio, G. G., Ghez, A., Gurwell, M. A., Haggard, D., Herrero-Illana, R., Hora, J. L., Li 李, Z. 志远, Liu 刘, J. 俊, Marchili, N., Morris, Mark R., Smith, Howard A., Subroweit, M., Zensus, J. A. · 2021 · The Astrophysical Journal
Cited by 75

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Sagittarius A* (Sgr A*) is the variable radio, near-infrared (NIR), and X-ray source associated with accretion onto the Galactic center black hole. We have analyzed a comprehensive submillimeter (including new observations simultaneous with NIR monitoring), NIR, and 2–8 keV data set. Submillimeter variations tend to lag those in the NIR by ∼30 minutes. An approximate Bayesian computation fit to the X-ray first-order structure function shows significantly less power at short timescales in the X-rays than in the NIR. Less X-ray variability at short timescales, combined with the observed NIR–X-ray correlations, means the variability can be described as the result of two strictly correlated stochastic processes, the X-ray process being the low-pass-filtered version of the NIR process. The NIR–X-ray linkage suggests a simple radiative model: a compact, self-absorbed synchrotron sphere with high-frequency cutoff close to NIR frequencies plus a synchrotron self-Compton scattering component at higher frequencies. This model, with parameters fit to the submillimeter, NIR, and X-ray structure functions, reproduces the observed flux densities at all wavelengths, the statistical properties of all light curves, and the time lags between bands. The fit also gives reasonable values for physical parameters such as magnetic flux density B ≈ 13 G, source size L ≈ 2.2 R S , and high-energy electron density n e ≈ 4 × 10 7 cm−3. An animation illustrates typical light curves, and we make public the parameter chain of our Bayesian analysis, the model implementation, and the visualization code.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3847/1538-4357/ac0891

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Witzel, G., Martinez, G., Willner, S. P., Becklin, E. E., Boyce, H., Do, T., Eckart, A., Fazio, G. G., Ghez, A., Gurwell, M. A., Haggard, D., Herrero-Illana, R., Hora, J. L., Li 李, Z. 志., Liu 刘, J. 俊., Marchili, N., Morris, M. R., Smith, H. A., Subroweit, M., & Zensus, J. A.
Venue
The Astrophysical Journal
Published
2021-08-01
Volume
917
Issue
2
Pages
73
ISSN
  • 0004-637X (ISSN-L)
  • 1538-4357
OpenAlex
W3106411158
Cited by
75
References
8
FWCI
6.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.