The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Diversity of cell-mediated adhesions in breast cancer spheroids
Abstract
Due to their three dimensional (3D) architecture, multicellular tumor spheroids mimic avascular tumor areas comprising the establishment of diffusion gradients, reduced proliferation rates and increased drug resistance. We have shown recently that the spontaneous formation of spheroids is restricted to a limited number of cell lines whereas the majority grow only as aggregates of cells with loose cell-cell contacts when cultured in 3D. However, by the addition of reconstituted basement membrane (rBM, Matrigel), aggregates can be transformed into spheroids with diffusion barriers and development of quiescent therapy-resistant cells. In this report, we investigated adhesion molecules responsible for rBM-driven versus spontaneous spheroid formation in a diverse population of eight breast tumor cell lines relevant for in vitro and in vivo antitumor drug testing. Inhibition of spheroid formation was monitored in the presence of adhesion molecule functional blocking antibodies and after siRNA-mediated down-regulation of E- and N-cadherin and integrin beta1 adhesion receptors. We identified that E-cadherin mediates the spontaneous formation of spheroids in MCF7, BT-474, T-47D and MDA-MB-361 cells, whereas N-cadherin is responsible for tight packing of MDA-MB-435S cells. In contrast, the matrix protein-induced transformation of 3D aggregates into spheroids in MDA-MB-231 and SK-BR-3 cells is mediated primarily by the collagen I/integrin beta1 interaction with no cadherin involvement. A combination of both, homophilic E-cadherin and integrin beta1/collagen I interaction establishes spheroids in MDA-MB-468 cells. These findings indicate that an evolutionary diverse and complex pattern of interacting cell surface proteins exists in breast cancer cells that determines the 3D growth characteristic in vitro, thereby influencing small molecule or antibody permeation in preclinical in vitro and in vivo tumor models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug penetration in solid tumours
Minchinton, A. I., & Tannock, I. F. (2006) · Nature reviews. Cancer · doi:10.1038/nrc1893 · Cited by 2,805
Cell and environment interactions in tumor microregions: the multicell spheroid model.
Sutherland, R. M. (1988) · Science · doi:10.1126/science.2451290 · Cited by 1,803
The use of 3-d cultures for high-throughput screening: the multicellular spheroid model.
Kunz-Schughart, L. A., Freyer, J. P., Hofstaedter, F., & Ebner, R. (2004) · SLAS DISCOVERY · doi:10.1177/1087057104265040 · Cited by 797
Grantab, R., Sivananthan, S., & Tannock, I. F. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-3077 · Cited by 254
Common origins of MDA-MB-435 cells from various sources with those shown to have melonoma properties
Rae, J. M., Ramus, S. J., Waltham, M., Armes, J. E., Campbell, I. G., Clarke, R., Barndt, R. J., Johnson, M. D., & Thompson, E. W. (2004) · Clinical & Experimental Metastasis · doi:10.1007/s10585-004-3759-1 · Cited by 74
Cited by
Three-dimensional cell culture: the missing link in drug discovery
Breslin, S., & O’Driscoll, L. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2012.10.003 · Cited by 1,332
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264
Vinci, M., Gowan, S., Boxall, F., Patterson, L., Zimmermann, M., Court, W., Lomas, C., Mendiola, M., Hardisson, D., & Eccles, S. A. (2012) · BMC Biology · doi:10.1186/1741-7007-10-29 · Cited by 1,024
“Since then, several methods have been used to generate tumor spheroids: spontaneous aggregation [19,20], spinner flasks [21], rotary cell culture systems [3,22], poly-2-hydroxyethyl methacrylate (polyHema)-coated plates [23,24], hanging drops [25], liquid overlay on agar [26-28], low binding plates [29,30], gel/ matri…”
Method3D tumor spheroids: an overview on the tools and techniques used for their analysis
Costa, E. C., Moreira, A. F., de Melo-Diogo, D., Gaspar, V. M., Carvalho, M. P., & Correia, I. J. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.11.002 · Cited by 929
Nunes, A. S., Barros, A. S., Costa, E. C., Moreira, A. F., & Correia, I. J. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26845 · Cited by 721
Metadata
- Authors
- Ivascu, A., & Kubbies, M.
- Venue
- International Journal of Oncology
- Publisher
- Spandidos Publications
- Published
- 2007-12-01
- Volume
- 31
- Issue
- 6
- Pages
- 1403-13
- ISSN
- 1019-6439 (ISSN-L)
- 1791-2423
- OpenAlex
- W2081424254
- Cited by
- 229
- References
- 5
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.