CoChat

A Novel in Vivo Skin Extensibility Test for Joint Hypermobility

Open access
FARMER, ADAM D., DOUTHWAITE, HATTY, GARDINER, SAM, AZIZ, QASIM, GRAHAME, RODNEY · 2010 · The Journal of Rheumatology
Cited by 25

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Objective.: The stress/strain curve derived from stretching skin is not linear, but follows a J-shaped curve. An initial generous yield is followed by a steep linear phase where considerable additional force is required to achieve modest increases in deformation. The former represents the taking up of slack resulting from the alignment of dermal collagen bundles in the line of force, while the gradient of the latter represents Young’s modulus for skin. Skin hyperextensibility in Ehlers-Danlos syndrome (EDS) is limited to the initial phase of taking up slack. Skin hyperextensibility and joint hypermobility (JHM) form part of the Revised 1998 Brighton diagnostic criteria for the benign joint hypermobility syndrome (BJHS), considered by many to be akin to EDS-hypermobility type. JHM may be screened for using the Beighton Score or a 5-point questionnaire. Our aim was to validate a novel method of measuring skin extensibility based on these observations in addition to revalidating the 5-point questionnaire. Methods.: 250 volunteers (131 female), median age 39 years (range 18–89 yrs), without BJHS, had their joint mobility evaluated using the Beighton Score, compared to the 5-point questionnaire. A Beighton score ≥ 4/9 was considered to represent JHM. Skin extensibility was determined by placing 2 dots on the dorsum of the right hand between the second and third metacarpals, approximately 10 mm apart, and was measured using an electronic caliper. Perpendicular to the metacarpals, a force was applied until the skin was fully taut and the increment was measured. Skin-fold thickness was measured using a Harpenden caliper. A corrected skin extensibility score (CSES) was calculated by dividing the percentage increment by skin thickness. Interobserver variability was measured in a further 50 healthy volunteers. Results.: The prevalence of JHM was 17.6%. Revalidation of the 5-point questionnaire returned a sensitivity of 0.85 and specificity of 0.85. The mean CSES was 23.84%/mm in the hypermobile group versus 13.55%/mm in the normal mobility group (p < 0.0001). CSES sensitivity was 0.72, specificity 0.75. The κ value for interobserver variability was 0.83. Conclusion.: The CSES is a useful and reproducible measure of skin extensibility in health. Further work is warranted to validate this test in patients with BJHS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3899/jrheum.091192

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
FARMER, A. D., DOUTHWAITE, H., GARDINER, S., AZIZ, Q., & GRAHAME, R.
Venue
The Journal of Rheumatology
Published
2010-06-15
Volume
37
Issue
7
Pages
1513-1518
ISSN
  • 0315-162X (ISSN-L)
  • 1499-2752
OpenAlex
W2067346297
Cited by
25
References
8
FWCI
1.01
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.