Spectrophotometric detection of rhodamine B in tap water, lipstick, rouge, and nail polish samples after supramolecular solvent microextraction
The DOI matches its Crossref record.
Abstract
A simple and sensitive supramolecular solvent-based dispersive liquid--liquid microextraction method was described for the separation/preconcentration and spectrophotometric detection of rhodamine B. The microextraction method, which was realized at ambient temperature for the detection of rhodamine B, was carried out by using supramolecular solvents such as tetrahydrofuran and decanoic acid. The method was based on analyses of rhodamine B by using UV-Vis spectrophotometry at 558 nm. The influences of some parameters such as pH, sample volume, eluent solutions, centrifugation time, and ultrasonic bath time were optimized. The effects of various matrix ions were also investigated. Moreover, the limit of detection and limit of quantification were calculated as 0.49 $\mu $g L$^{-1}$ and 1.47 $\mu $g L$^{-1}$, respectively. The preconcentration factor was 30. The relative standard deviation was determined as 5.8% in 0.5 $\times $ 10$^{-4}$ M rhodamine B. The procedure was validated by addition/recovery tests. The microextraction method was applied to determination of rhodamine B in tap water samples and cosmetic samples such as nail polish, rouge, and lipstick.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analysis of Dyes in Cosmetics: Challenges and Recent Developments
Guerra, E., Llompart, M., & Garcia-Jares, C. (2018) · Cosmetics · doi:10.3390/cosmetics5030047 · Cited by 183
Liquid-phase microextraction of polycyclic aromatic hydrocarbons: A review
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Reviews in Analytical Chemistry · doi:10.1515/revac-2020-0101 · Cited by 50
Zhao, W., Jing, X., Tian, Y., & Feng, C. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105416 · Cited by 43
Metadata
- Authors
- ÖZKANTAR, N., SOYLAK, M., & TÜZEN, M.
- Venue
- TURKISH JOURNAL OF CHEMISTRY
- Published
- 2017
- Volume
- 41
- Pages
- 987-994
- ISSN
- 1300-0527 (ISSN-L)
- 1303-6130
- OpenAlex
- W2779394717
- Cited by
- 49
- References
- 0
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectrophotometric detection of rhodamine B in tap water, lipstick, rouge, and nail polish samples after supramolecular solvent microextraction. https://app.cochat.ai/papers/10.3906/kim-1702-72
- The paper
- ÖZKANTAR, N., SOYLAK, M., & TÜZEN, M. (2017). Spectrophotometric detection of rhodamine B in tap water, lipstick, rouge, and nail polish samples after supramolecular solvent microextraction. TURKISH JOURNAL OF CHEMISTRY. https://doi.org/10.3906/kim-1702-72
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.