Abstract

Seventy paraplegics were fitted with an improved Reciprocating Gait Orthosis powered with or without (low-level injury) electrical stimulation of the thigh muscles (RGO II) as a secondary rehabilitation phase after the acute period. The patients comprised a broad cross-section of the paraplegic population applying for medical services and varied in age from 16 to 55 years, time since injury ranging from less than 1 to 15 years, injury levels ranging from C-6/7 to T-11/12, and varying levels of spasticity, contractures, scoliosis and other related medical and physiologic problems. The success/failure ratio was dependent on the injury level, which was 1:1 for paraplegics with injury level at C-6/7; 1.67:1 for those with injury of T-1/3; and about 4:1 for paraplegics with injury level from T-3 to T-12. Lack of motivation and medical problems unrelated to the RGO II treatment were the primary reasons for failure. The duration of treatment (outpatient service three times per week) ranged from 2 to 48 weeks (mean: 16). Forty-one patients who completed the RGO II rehabilitation and were sent home with the orthosis for independent use (for at least 6 months and up to 3 years) were surveyed by a staff member for analysis of the meaning and impact of the RGO II on the patient's life and health, and potential problems. It was shown that 80.5% of the 41 patients were regular users and 19.5% were non-users. Thirty-eight of the 41 patients declined an offer to return the RGO II equipment for a full refund, while three patients were willing to return the orthosis. It was concluded that the RGO II is a viable orthosis for restoring standing and limited walking in paraplegics while providing sufficient function, safety, and reliability. The most appropriate patients for the use of such an orthosis consist primarily of those with T-3 to T-12 injury level and good motivation, although highly selected patients with higher injury levels also can benefit from its use. Regular use of the RGO II, even for exercise only, had a general positive impact on the patients' health and outlook.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/0147-7447-19970401-08

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 118

Metadata

Authors
Solomonow, M., Aguilar, E., Reisin, E., Baratta, R. V., Best, R., Coetzee, T., & D'Ambrosia, R.
Venue
Orthopedics
Publisher
SLACK, Inc.
Published
1997-04
Volume
20
Issue
4
Pages
315-324
ISSN
  • 0147-7447 (ISSN-L)
  • 1938-2367
OpenAlex
W2237549767
Cited by
118
References
2
FWCI
4.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reciprocating Gait Orthosis Powered with Electrical Muscle Stimulation (RGO II). Part I: Performance Evaluation of 70 Paraplegic Patients. https://app.cochat.ai/papers/10.3928/0147-7447-19970401-08
The paper
Solomonow, M., Aguilar, E., Reisin, E., Baratta, R. V., Best, R., Coetzee, T., & D'Ambrosia, R. (1997). Reciprocating Gait Orthosis Powered with Electrical Muscle Stimulation (RGO II). Part I: Performance Evaluation of 70 Paraplegic Patients. Orthopedics. https://doi.org/10.3928/0147-7447-19970401-08

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.