Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound

Open access
Reinstein, Dan Z., Archer, Timothy J., Gobbe, Marine, Silverman, Ronald H., Coleman, D. Jackson·2009·Journal of Refractive Surgery

Abstract

Purpose: To characterize the stromal thickness profile in a population of normal eyes. Methods: Stromal thickness profile was measured in vivo by Artemis very high-frequency digital ultrasound scanning (ArcScan, Morrison, Colo) across the central 10-mm corneal diameter on 110 normal eyes. Maps of the average, standard deviation, minimum, maximum, and range of stromal thickness were plotted. The average location of the thinnest stroma was found. The cross-sectional hemi-meridional stromal thickness profile was calculated using annular averaging. The absolute stromal thickness progression relative to the thinnest point was calculated using annular averaging as well as for 8 hemi-meridians individually. Results: The mean stromal thickness at the corneal vertex and at the thinnest point were 465.4±36.9 µ m and 461.8±37.3 µ m, respectively. The thinnest stroma was displaced on average 0.17±0.31 mm inferiorly and 0.33±0.40 mm temporally from the corneal vertex. The average absolute stromal thickness progression from the thinnest point could be described by the quadratic equation: stromal thickness = 6.411 × radius 2 + 2.444 × radius (R 2 = 0.999). Absolute stromal thickness progression was independent of stromal thickness at the thinnest point. The increase in hemi-meridional absolute stromal thickness progression was greatest superiorly and lowest temporally. Conclusions: Three-dimensional thickness mapping of the corneal stroma and stromal thickness progression in a population of normal eyes represent a normative data set, which may help in early diagnosis of corneal abnormalities such as keratoconus and pellucid marginal degeneration. Absolute stromal thickness progression was found to be independent of stromal thickness. [ J Refract Surg . 2009;25:776–786.]

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/1081597x-20090813-04

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Research works printed but not linked: 14

  1. 10.1016/j.jcrs.2006.07.016 · doi:10.1016/j.jcrs.2006.07.016
  2. 10.3928/1081-597X-20061101-04 · doi:10.3928/1081-597x-20061101-04
  3. 10.1001/archopht.1969.00990020184006 · doi:10.1001/archopht.1969.00990020184006
  4. 10.1016/S0161-6420(99)00022-6 · doi:10.1016/s0161-6420(99)00022-6
  5. 10.1016/S0886-3350(02)01275-0 · doi:10.1016/s0886-3350(02)01275-0
  6. 10.1016/S0161-6420(98)93211-0 · doi:10.1016/s0161-6420(98)93211-0
  7. 10.1016/j.jcrs.2006.08.020 · doi:10.1016/j.jcrs.2006.08.020
  8. 10.3928/1081-597X-20010501-04 · doi:10.3928/1081-597x-20010501-04
  9. 10.1097/00003226-199211000-00012 · doi:10.1097/00003226-199211000-00012
  10. Reinstein DZ, Archer TJ, Gobbe M. Exclusion of keratoconus initially diagnosed by Orbscan using epithelial and stromal layer thickness mapping. Presented at: American Academy of Ophthalmology Annual Meeting; November 11–14, 2006; Las Vegas, Nev.
  11. 10.5962/bhl.title.160281 · doi:10.5962/bhl.title.160281
  12. 10.1097/01.ico.0000127486.78424.6e · doi:10.1097/01.ico.0000127486.78424.6e
  13. 10.1097/00006324-199407000-00003 · doi:10.1097/00006324-199407000-00003
  14. 10.3928/1081597X-20090422-07 · doi:10.3928/1081597x-20090422-07

Cited by

See all 299

Metadata

Authors
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J.
Venue
Journal of Refractive Surgery
Publisher
SLACK, Inc.
Published
2009-09
Volume
25
Issue
9
Pages
776-786
ISSN
  • 1042-962X (ISSN-L)
  • 1081-597X
OpenAlex
W2083655341
Cited by
299
References
43
FWCI
13.86
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound. https://app.cochat.ai/papers/10.3928/1081597x-20090813-04
The paper
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2009). Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound. Journal of Refractive Surgery. https://doi.org/10.3928/1081597x-20090813-04

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.