Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound
Open accessAbstract
Purpose: To characterize the stromal thickness profile in a population of normal eyes. Methods: Stromal thickness profile was measured in vivo by Artemis very high-frequency digital ultrasound scanning (ArcScan, Morrison, Colo) across the central 10-mm corneal diameter on 110 normal eyes. Maps of the average, standard deviation, minimum, maximum, and range of stromal thickness were plotted. The average location of the thinnest stroma was found. The cross-sectional hemi-meridional stromal thickness profile was calculated using annular averaging. The absolute stromal thickness progression relative to the thinnest point was calculated using annular averaging as well as for 8 hemi-meridians individually. Results: The mean stromal thickness at the corneal vertex and at the thinnest point were 465.4±36.9 µ m and 461.8±37.3 µ m, respectively. The thinnest stroma was displaced on average 0.17±0.31 mm inferiorly and 0.33±0.40 mm temporally from the corneal vertex. The average absolute stromal thickness progression from the thinnest point could be described by the quadratic equation: stromal thickness = 6.411 × radius 2 + 2.444 × radius (R 2 = 0.999). Absolute stromal thickness progression was independent of stromal thickness at the thinnest point. The increase in hemi-meridional absolute stromal thickness progression was greatest superiorly and lowest temporally. Conclusions: Three-dimensional thickness mapping of the corneal stroma and stromal thickness progression in a population of normal eyes represent a normative data set, which may help in early diagnosis of corneal abnormalities such as keratoconus and pellucid marginal degeneration. Absolute stromal thickness progression was found to be independent of stromal thickness. [ J Refract Surg . 2009;25:776–786.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Worthen, D. M. (1972) · Archives of Ophthalmology · doi:10.1001/archopht.1972.01000030236034 · Cited by 798
Analysis of blink rate patterns in normal subjects
Bentivoglio, A. R., Bressman, S. B., Cassetta, E., Carretta, D., Tonali, P., & Albanese, A. (1997) · Movement Disorders · doi:10.1002/mds.870120629 · Cited by 512
Changes in Collagen Orientation and Distribution in Keratoconus Corneas
Meek, K. M., Tuft, S. J., Huang, Y., Gill, P. S., Hayes, S., Newton, R. H., & Bron, A. J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1253 · Cited by 509
Ambrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.06.025 · Cited by 451
Interaction of Eyelids and Tears in Corneal Wetting and the Dynamics of the Normal Human Eyeblink
Doane, M. G. (1980) · American Journal of Ophthalmology · doi:10.1016/0002-9394(80)90058-6 · Cited by 395
Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080601-05 · Cited by 379
Self-citationEpithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF)
Li, H. F., Petroll, W. M., Møller‐Pedersen, T., Maurer, J. K., Cavanagh, H. D., & Jester, J. V. (1997) · Current Eye Research · doi:10.1076/ceyr.16.3.214.15412 · Cited by 332
Cell Production and Migration in the Epithelial Layer of the Cornea
HANNA, C., & O'BRIEN, J. E. (1960) · Archives of Ophthalmology · doi:10.1001/archopht.1960.01840010538009 · Cited by 328
Patel, S. V., McLaren, J. W., Hodge, D. O., & Bourne, W. M. (2001) · PubMed · Cited by 286
Research works printed but not linked: 14
- 10.1016/j.jcrs.2006.07.016 · doi:10.1016/j.jcrs.2006.07.016
- 10.3928/1081-597X-20061101-04 · doi:10.3928/1081-597x-20061101-04
- 10.1001/archopht.1969.00990020184006 · doi:10.1001/archopht.1969.00990020184006
- 10.1016/S0161-6420(99)00022-6 · doi:10.1016/s0161-6420(99)00022-6
- 10.1016/S0886-3350(02)01275-0 · doi:10.1016/s0886-3350(02)01275-0
- 10.1016/S0161-6420(98)93211-0 · doi:10.1016/s0161-6420(98)93211-0
- 10.1016/j.jcrs.2006.08.020 · doi:10.1016/j.jcrs.2006.08.020
- 10.3928/1081-597X-20010501-04 · doi:10.3928/1081-597x-20010501-04
- 10.1097/00003226-199211000-00012 · doi:10.1097/00003226-199211000-00012
- Reinstein DZ, Archer TJ, Gobbe M. Exclusion of keratoconus initially diagnosed by Orbscan using epithelial and stromal layer thickness mapping. Presented at: American Academy of Ophthalmology Annual Meeting; November 11–14, 2006; Las Vegas, Nev.
- 10.5962/bhl.title.160281 · doi:10.5962/bhl.title.160281
- 10.1097/01.ico.0000127486.78424.6e · doi:10.1097/01.ico.0000127486.78424.6e
- 10.1097/00006324-199407000-00003 · doi:10.1097/00006324-199407000-00003
- 10.3928/1081597X-20090422-07 · doi:10.3928/1081597x-20090422-07
Cited by
Corneal structure and transparency
Meek, K. M., & Knupp, C. (2015) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.001 · Cited by 853
Keeping an Eye on Decellularized Corneas: A Review of Methods, Characterization and Applications
Wilson, S., Sidney, L., Dunphy, S., Rose, J., & Hopkinson, A. (2013) · Journal of Functional Biomaterials · doi:10.3390/jfb4030114 · Cited by 100
Ultraviolet light transmission through the human corneal stroma is reduced in the periphery
Doutch, J. J., Quantock, A. J., Joyce, N. C., & Meek, K. M. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2012.02.023 · Cited by 50
Mallet, J. D., Dorr, M. M., Drigeard Desgarnier, M.-C., Bastien, N., Gendron, S. P., & Rochette, P. J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0162212 · Cited by 40
Metadata
- Authors
- Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2009-09
- Volume
- 25
- Issue
- 9
- Pages
- 776-786
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2083655341
- Cited by
- 299
- References
- 43
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound. https://app.cochat.ai/papers/10.3928/1081597x-20090813-04
- The paper
- Reinstein, D. Z., Archer, T. J., Gobbe, M., Silverman, R. H., & Coleman, D. J. (2009). Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital Ultrasound. Journal of Refractive Surgery. https://doi.org/10.3928/1081597x-20090813-04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.