The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual Capsulotomies
Abstract
PURPOSE: To evaluate a laser technique and manual technique to perform capsulorrhexis in cataract eyes. METHODS: Anterior capsulotomy was performed with an intraocular femtosecond laser (LenSx Lasers Inc) in 54 eyes (FS group) and manual continuous curvilinear capsulorrhexis was performed in 57 eyes (CCC group). Circularity and area of capsulotomy and IOL decentration were measured using Photoshop CS4 Extended (Adobe Systems Inc) 1 week after surgery. Average keratometry, axial length, and preoperative anterior chamber depth were examined with the Lenstar LS 900 (Haag-Streit AG). RESULTS: No statistically significant differences were noted between groups in axial length, preoperative refractive state, and in the area of capsulotomy. Circularity values were significantly better in the FS group ( P =.032). We found incomplete overlap of capsulotomies in 28% of eyes in the CCC group and 11% in the FS group ( P =.033). Significant correlations were noted between axial length and area of capsulotomy, and between average keratometry and area of the capsulotomy in the CCC group (R=0.278, P =.036; and R=−0.29, P =.033, respectively), but both did not correlate in the FS group ( P >.05). In the CCC group, the pupillary area correlated significantly with the area of the capsulotomy (R=0.27, P =.039). Significant correlation was noted between IOL decentration and axial length in the CCC group (R=0.30, P =.026), but there was no correlation in the FS group ( P >.05). CONCLUSIONS: Femtosecond laser capsulorrhexis was more regularly shaped, showed better centration, and showed a better intraocular lens/capsule overlap than manual capsulorrhexis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20091117-04 · Cited by 563
Self-citationPupil location under mesopic, photopic, and pharmacologically dilated conditions.
Yang, Y., Thompson, K. P., & Burns, S. A. (2002) · PubMed · Cited by 230
Krueger, R. R., Kuszak, J. R., Lubatschowski, H., Myers, R., Ripken, T., & Heisterkamp, A. (2005) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2005.05.034 · Cited by 80
Cited by
Carbon footprint and cost–effectiveness of cataract surgery
Venkatesh, R., van Landingham, S. W., Khodifad, A. M., Haripriya, A., Thiel, C. L., Ramulu, P., & Robin, A. L. (2016) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000228 · Cited by 76
Metadata
- Authors
- Nagy, Z. Z., Kránitz, K., Takacs, A. I., Miháltz, K., Kovács, I., & Knorz, M. C.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2011-08
- Volume
- 27
- Issue
- 8
- Pages
- 564-569
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2127989468
- Cited by
- 268
- References
- 3
- FWCI
- 22.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual Capsulotomies. https://app.cochat.ai/papers/10.3928/1081597x-20110607-01
- The paper
- Nagy, Z. Z., Kránitz, K., Takacs, A. I., Miháltz, K., Kovács, I., & Knorz, M. C. (2011). Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual Capsulotomies. Journal of Refractive Surgery. https://doi.org/10.3928/1081597x-20110607-01
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.