Carbon footprint and cost–effectiveness of cataract surgery
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: This article raises awareness about the cost-effectiveness and carbon footprint of various cataract surgery techniques, comparing their relative carbon emissions and expenses: manual small-incision cataract surgery (MSICS), phacoemulsification, and femtosecond laser-assisted cataract surgery. RECENT FINDINGS: As the most commonly performed surgical procedure worldwide, cataract surgery contributes significantly to global climate change. The carbon footprint of a single phacoemulsification cataract surgery is estimated to be comparable to that of a typical person's life for 1 week. Phacoemulsification has been estimated to be between 1.4 and 4.7 times more expensive than MSICS; however, given the lower degree of postoperative astigmatism and other potential complications, phacoemulsification may still be preferable to MSICS in relatively resource-rich settings requiring high levels of visual function. Limited data are currently available regarding the environmental and financial impact of femtosecond laser-assisted cataract surgery; however, in its current form, it appears to be the least cost-effective option. SUMMARY: Cataract surgery has a high value to patients. The relative environmental impact and cost of different types of cataract surgery should be considered as this treatment becomes even more broadly available globally and as new technologies are developed and implemented.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There is substantial variability in waste generation and emissions from cataract surgery in different countries, suggesting improvements are possible.29,33,39”
From How Ophthalmologists Can Decarbonize Eye Care (2023) · cites this paper as [33]
Citations
Cites
Global estimates of visual impairment: 2010
Pascolini, D., & Mariotti, S. P. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300539 · Cited by 3,763
Managing the health effects of climate change
Costello, A., Abbas, M., Allen, A., Ball, S., Bell, S., Bellamy, R., Friel, S., Groce, N., Johnson, A., Kett, M., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60935-1 · Cited by 3,102 · cited 1×
“Climate change is predicted to be one of the largest global health threats of the 21st century [2].”
BackgroundLaupacis, A., Feeny, D. H., Detsky, A. S., & Tugwell, P. (1992) · Europe PMC (PubMed Central) · Cited by 1,719
Thiel, C. L., Eckelman, M., Guido, R., Huddleston, M., Landis, A. E., Sherman, J., Shrake, S. O., Copley-Woods, N., & Bilec, M. M. (2015) · Environmental Science & Technology · doi:10.1021/es504719g · Cited by 416
Self-citationEstimate of the carbon footprint of the US health care sector
Chung, J. W., & Meltzer, D. O. (2009) · JAMA · doi:10.1001/jama.2009.1610 · Cited by 415
Friedman, N. J., Palanker, D. V., Schuele, G., Andersen, D., Marcellino, G., Seibel, B. S., Batlle, J., Feliz, R., Talamo, J. H., Blumenkranz, M. S., et al. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.04.022 · Cited by 373
Ruit, S., Tabin, G., Chang, D., Bajracharya, L., Kline, D. C., Richheimer, W., Shrestha, M., & Paudyal, G. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.07.023 · Cited by 300
Femtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence Tomography
Palanker, D. V., Blumenkranz, M. S., Andersen, D., Wiltberger, M., Marcellino, G., Gooding, P., Angeley, D., Schuele, G., Woodley, B., Simoneau, M., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001305 · Cited by 277
Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual Capsulotomies
Nagy, Z. Z., Kránitz, K., Takacs, A. I., Miháltz, K., Kovács, I., & Knorz, M. C. (2011) · Journal of Refractive Surgery · doi:10.3928/1081597x-20110607-01 · Cited by 268
The carbon footprint of cataract surgery
Morris, D. S., Wright, T., Somner, J. E. A., & Connor, A. (2013) · Eye · doi:10.1038/eye.2013.9 · Cited by 238
Research works printed but not linked: 2
- Somner, 2009, urg, 35, 202
- Laupacis, 1992, CMAJ, 146, 473
Cited by
The Lancet Global Health Commission on Global Eye Health: vision beyond 2020
Burton, M. J., Ramke, J., Marques, A. P., Bourne, R. R. A., Congdon, N., Jones, I., Ah Tong, B. A. M., Arunga, S., Bachani, D., Bascaran, C., et al. (2021) · The Lancet Global Health · doi:10.1016/s2214-109x(20)30488-5 · Cited by 1,624
International comparison of health care carbon footprints
Pichler, P.-P., Jaccard, I. S., Weisz, U., & Weisz, H. (2019) · Environmental Research Letters · doi:10.1088/1748-9326/ab19e1 · Cited by 812
Eckelman, M. J., Sherman, J. D., & MacNeill, A. J. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002623 · Cited by 346
The green print: Advancement of environmental sustainability in healthcare
Sherman, J. D., Thiel, C., MacNeill, A., Eckelman, M. J., Dubrow, R., Hopf, H., Lagasse, R., Bialowitz, J., Costello, A., Forbes, M., et al. (2020) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2020.104882 · Cited by 327
Self-citationThiel, C. L., Schehlein, E., Ravilla, T., Ravindran, R. D., Robin, A. L., Saeedi, O. J., Schuman, J. S., & Venkatesh, R. (2017) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2017.08.017 · Cited by 265
Self-citation
Metadata
- Authors
- Venkatesh, R., van Landingham, S. W., Khodifad, A. M., Haripriya, A., Thiel, C. L., Ramulu, P., & Robin, A. L.
- Affiliations
- Johns Hopkins University (US)
- University of Maryland, Baltimore (US)
- Corresponding author
- Robin, Alan L.
- Venue
- Current Opinion in Ophthalmology
- Published
- 2016-01
- Volume
- 27
- Issue
- 1
- Pages
- 82-88
- ISSN
- 1040-8738 (ISSN-L)
- OpenAlex
- W2395825725
- Cited by
- 76
- References
- 31
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 10 · 2023: 4 · 2022: 14 · 2021: 8 · 2020: 7 · 2019: 3 · 2018: 7 · 2017: 6 · 2016: 1
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Opinion in Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Physical Sciences › Environmental Science › Environmental Engineering › Environmental Impact and Sustainability
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Global Health and Surgery
- Keywords
- cataract surgery, carbon footprint, cost-effectiveness, phacoemulsification, femtosecond laser-assisted cataract surgery, manual small incision cataract surgery, CO2 emissions, climate change, postoperative astigmatism, surgical complications
- MeSH terms
- Astigmatism, Cataract, Cataract Extraction, Cost-Benefit Analysis, Humans, Postoperative Period, Phacoemulsification, Carbon Footprint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon footprint and cost–effectiveness of cataract surgery. https://app.cochat.ai/papers/10.1097/icu.0000000000000228
- The paper
- Venkatesh, R., van Landingham, S. W., Khodifad, A. M., Haripriya, A., Thiel, C. L., Ramulu, P., & Robin, A. L. (2016). Carbon footprint and cost–effectiveness of cataract surgery. Current Opinion in Ophthalmology. https://doi.org/10.1097/icu.0000000000000228
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.