Detection of Keratoconus With a New Biomechanical Index
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the ability of a new combined biomechanical index called the Corvis Biomechanical Index (CBI) based on corneal thickness profile and deformation parameters to separate normal from keratoconic patients. METHODS: Six hundred fifty-eight patients (329 eyes in each database) were included in this multicenter retrospective study. Patients from two clinics located on different continents were selected to test the capability of the CBI to separate healthy and keratoconic eyes in more than one ethnic group using the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). Logistic regression was employed to determine, based on Database 1 as the development dataset, the optimal combination of parameters to accurately separate normal from keratoconic eyes. The CBI was subsequently independently validated on Database 2. RESULTS: The CBI included several dynamic corneal response parameters: deformation amplitude ratio at 1 and 2 mm, applanation 1 velocity, standard deviation of deformation amplitude at highest concavity, Ambrósio's Relational Thickness to the horizontal profile, and a novel stiffness parameter. The receiver operating characteristic curve analysis of the training database showed an area under the curve of 0.983. With a cut-off value of 0.5, 98.2% of the cases were correctly classified with 100% specificity and 94.1% sensitivity. In the validation dataset, the same cut-off point correctly classified 98.8% of the cases with 98.4% specificity and 100% sensitivity. CONCLUSIONS: The CBI was shown to be highly sensitive and specific to separate healthy from keratoconic eyes. The presence of an external validation dataset confirms this finding and suggests the possible use of the CBI in everyday clinical practice to aid in the diagnosis of keratoconus. [ J Refract Surg. 2016;32(12):803–810.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Self-citationBiomechanical properties of keratoconus and normal corneas
Andreassen, T. T., Hjorth Simonsen, A., & Oxlund, H. (1980) · Experimental Eye Research · doi:10.1016/s0014-4835(80)80027-3 · Cited by 540
Biomechanical Characterization of Keratoconus Corneas Ex Vivo With Brillouin Microscopy
Scarcelli, G., Besner, S., Pineda, R., & Yun, S. H. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14450 · Cited by 250
Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
Ambrósio Jr, R., Ramos, I., Luz, A., Faria, F. C., Steinmueller, A., Krug, M., Belin, M. W., & Roberts, C. J. (2013) · Revista Brasileira de Oftalmologia · doi:10.1590/s0034-72802013000200005 · Cited by 205
Self-citationApplication of structural analysis to the mechanical behaviour of the cornea
Anderson, K., El-Sheikh, A., & Newson, T. (2004) · Journal of The Royal Society Interface · doi:10.1098/rsif.2004.0002 · Cited by 205
Self-citationDiscriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Keratoconus
Hallahan, K., Roy, A. S., Ambrósio, R., Salomão, M. Q., & Dupps, W. J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.09.013 · Cited by 90
Self-citationHorizontal pachymetric profile for the detection of keratoconus
Lopes, B. T., Ramos, I. C. D. O., Salomão, M. Q., Canedo, A. L., & Ambrósio, R. (2015) · Revista Brasileira de Oftalmologia · doi:10.5935/0034-7280.20150080 · Cited by 29
Self-citation
Cited by
Ambrósio, R., Lopes, B. T., Faria-Correia, F., Salomão, M. Q., Bühren, J., Roberts, C. J., Elsheikh, A., Vinciguerra, R., & Vinciguerra, P. (2017) · Journal of Refractive Surgery · doi:10.3928/1081597x-20170426-02 · Cited by 477
Self-citationEliasy, A., Chen, K.-J., Vinciguerra, R., Lopes, B. T., Abass, A., Vinciguerra, P., Ambrósio Jr., R., Roberts, C. J., & Elsheikh, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00105 · Cited by 221
“With successful validation, SSI could help in identifying eyes with keratoconus, possibly increasing the sensitivity and specificity of indexes such as the Corvis Combined Biomechanical Index (CBI) (Vinciguerra et al., 2016) or the Tomography and Biomechanical Index (TBI) (Ambrósio et al., 2017b).”
MethodSelf-citationEnhanced Tomographic Assessment to Detect Corneal Ectasia Based on Artificial Intelligence
Lopes, B. T., Ramos, I. C., Salomão, M. Q., Guerra, F. P., Schallhorn, S. C., Schallhorn, J. M., Vinciguerra, R., Vinciguerra, P., Price, F. W., Price, M. O., et al. (2018) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2018.08.005 · Cited by 205
Self-citationKwok, S., Clayson, K., Hazen, N., Pan, X., Ma, Y., Hendershot, A. J., & Liu, J. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.13.33 · Cited by 19
Metadata
- Authors
- Vinciguerra, R., Ambrósio, R., Elsheikh, A., Roberts, C. J., Lopes, B., Morenghi, E., Azzolini, C., & Vinciguerra, P.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2016-12
- Volume
- 32
- Issue
- 12
- Pages
- 803-810
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2559749448
- Cited by
- 502
- References
- 8
- FWCI
- 24.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.