Tissue Plasminogen Activating Factor Assisted Removal of Subretinal Hemorrhage
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We used tissue plasminogen activator (tPA) to aid in the surgical evacuation of subretinal hemorrhages. Subretinal hemorrhage secondary to a ruptured retinal macroaneurysm was treated in two patients. The surgical technique involved using a micropipette to fashion a small retinotomy through which tPA was injected into the subretinal space and through which the dissolved clot was removed. Visual acuity improved from counts fingers to 20/50 in one patient and from counts fingers to 20/70 in the other. Three additional patients, with massive subretinal hemorrhages secondary to age-related macular degeneration, were similarly treated. In one, visual acuity improved from counts fingers to 20/400; in two others, visual acuity was stabilized; in the first patient, at 20/300, and in the second patient at 20/400. The use of tPA minimizes surgical manipulation of the sensory retina and greatly reduces the size of the retinotomy required for evacuation of subretinal blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental subretinal hemorrhage in rabbits
Glatt, H., & Machemer, R. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90301-4 · Cited by 401
(1986) · Archives of Ophthalmology · doi:10.1001/archopht.1986.01050170084028 · Cited by 227
Cited by
Schmidt-Erfurth, U., Chong, V., Loewenstein, A., Larsen, M., Souied, E., Schlingemann, R., Eldem, B., Monés, J., Richard, G., & Bandello, F. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-305702 · Cited by 639
Haupert, C. L., McCuen, B. W., Jaffe, G. J., Steuer, E. R., Cox, T. A., Toth, C. A., Fekrat, S., & Postel, E. A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00734-0 · Cited by 233
First-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
Pathophysiology and management of subretinal hemorrhage
Hochman, M. A., Seery, C. M., & Zarbin, M. A. (1997) · Survey of Ophthalmology · doi:10.1016/s0039-6257(97)00089-1 · Cited by 186
Submacular hemorrhage in neovascular age-related macular degeneration: a synthesis of the literature
Stanescu-Segall, D., Balta, F., & Jackson, T. L. (2016) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2015.04.004 · Cited by 175
Metadata
- Authors
- Peyman, G. A., Nelson, N. C., Alturki, W., Blinder, K. J., Paris, C. L., Desai, U. R., & Harper, C. A.
- Venue
- Ophthalmic Surgery, Lasers and Imaging Retina
- Publisher
- SLACK, Inc.
- Published
- 1991-10
- Volume
- 22
- Issue
- 10
- Pages
- 575-582
- ISSN
- 1542-8877 (ISSN-L)
- 2325-8160
- 2325-8179
- OpenAlex
- W176826057
- Cited by
- 101
- References
- 2
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue Plasminogen Activating Factor Assisted Removal of Subretinal Hemorrhage. https://app.cochat.ai/papers/10.3928/1542-8877-19911001-07
- The paper
- Peyman, G. A., Nelson, N. C., Alturki, W., Blinder, K. J., Paris, C. L., Desai, U. R., & Harper, C. A. (1991). Tissue Plasminogen Activating Factor Assisted Removal of Subretinal Hemorrhage. Ophthalmic Surgery, Lasers and Imaging Retina. https://doi.org/10.3928/1542-8877-19911001-07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.