CoChat

Subretinal Semiconductor Microphotodiode Array

Peyman, Gholam, Chow, Alan Y, Liang, Chanping, Chow, Vincent Y, Perlman, Jay I, Peachey, Neal S · 1998 · Ophthalmic Surgery, Lasers and Imaging Retina
Cited by 115

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

* BACKGROUND AND OBJECTIVE: To examine the function of a semiconductor microphotodiode array (SMA) surgically implanted in the subretinal space. * MATERIALS AND METHODS: Positive-intrinsic layer-negative (PiN) or negative-intrinsic layer-positive (NiP) SMAs were surgically placed into the subretinal space of rabbits through a pars plana incision and a posterior retinotomy. The implants required no external connections for power and were sensitive to light over the visible and infrared (IR) spectrum; IR stimuli were used to isolate implant-mediated responses from the activity of native photoreceptors. A stimulator ophthalmoscope was used to superimpose IR stimuli on the implant and adjacent retinal areas, and responses were recorded during the postoperative recovery period. SMA responses were also evaluated in vitro. The animals were given lethal anesthetic overdoses, and the retinas were examined histologically. * RESULTS: The in vitro implant response consisted of an electrical spike, followed by a small-amplitude DC offset that followed the time course of the IR stimulation, and an overshoot at the stimulus offset. The SMAs placed in the subretinal space retained a stable position and continued to function throughout the postoperative period. The SMA responses recorded in vivo included additional slow-wave components that were absent from the in vitro recordings. These responses reverted to the in vitro configuration following the death of the animal. There was a significant loss of retinal cells in areas overlying the implant, and the retina appeared normal away from the implant and surgical site. * CONCLUSION: SMAs can be successfully implanted into the subretinal space and will generate current in response to light stimulation during an extended period of time. [Ophthalmic Surg Lasers 1998;29:234-241.]

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/1542-8877-19980301-10

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 115

Metadata

Authors
Peyman, G., Chow, A. Y., Liang, C., Chow, V. Y., Perlman, J. I., & Peachey, N. S.
Venue
Ophthalmic Surgery, Lasers and Imaging Retina
Publisher
SLACK, Inc.
Published
1998-03
Volume
29
Issue
3
Pages
234-241
ISSN
  • 1542-8877 (ISSN-L)
  • 2325-8160
  • 2325-8179
OpenAlex
W2228542861
Cited by
115
References
3
FWCI
2.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Subretinal Semiconductor Microphotodiode Array. https://app.cochat.ai/papers/10.3928/1542-8877-19980301-10
The paper
Peyman, G., Chow, A. Y., Liang, C., Chow, V. Y., Perlman, J. I., & Peachey, N. S. (1998). Subretinal Semiconductor Microphotodiode Array. Ophthalmic Surgery, Lasers and Imaging Retina. https://doi.org/10.3928/1542-8877-19980301-10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.