Swept-Source OCT Angiography of the Retinal Vasculature Using Intensity Differentiation-based Optical Microangiography Algorithms
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND OBJECTIVE: To demonstrate the feasibility of using a 1,050-nm swept-source optical coherence tomography (SS-OCT) system to achieve noninvasive retinal vasculature imaging in human eyes. MATERIALS AND METHODS: Volumetric data sets were acquired using a 1-µm SS-OCT prototype that operated at a 100-kHz A-line rate. A scanning protocol designed to allow for motion contrast processing, referred to as OCT angiography or optical microangiography (OMAG), was used to scan an approximately 3 × 3–mm area in the central macular region of the retina within approximately 4.5 seconds. An intensity differentiation-based OMAG algorithm was used to extract three-dimensional retinal functional microvasculature information. RESULTS: Intensity signal differentiation generated capillary-level resolution en face OMAG images of the retina. The parafoveal capillaries were clearly visible, thereby allowing visualization of the foveal avascular zone in healthy subjects. CONCLUSION: The capability of OMAG to produce retinal vascular images was demonstrated using the 1-µm SS-OCT prototype. This technique has potential clinical value for studying retinal vasculature abnormalities. [ Ophthalmic Surg Lasers Imaging Retina. 2014;45:382–389.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Self-citationPotsaid, B. M., Baumann, B., Huang, D., Barry, S., Cable, A., Schuman, J. S., Duker, J. S., & Fujimoto, J. G. (2010) · Optics Express · doi:10.1364/oe.18.020029 · Cited by 531
Idiopathic Macular Telangiectasia
Yannuzzi, L. A. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.4.450 · Cited by 474
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
Chen, Z., Milner, T. E., Dave, D., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000064 · Cited by 443
Wang, R. K., An, L., Francis, P., & Wilson, D. J. (2010) · Optics Letters · doi:10.1364/ol.35.001467 · Cited by 355
Self-citationArend, O., Wolf, S., Jung, F., Bertram, B., Postgens, H., Toonen, H., & Reim, M. (1991) · British Journal of Ophthalmology · doi:10.1136/bjo.75.9.514 · Cited by 302
Ophthalmic fundus imaging: today and beyond
Yannuzzi, L. A., Ober, M. D., Slakter, J. S., Spaide, R. F., Fisher, Y. L., Flower, R. W., & Rosen, R. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2003.12.035 · Cited by 207
User-guided segmentation for volumetric retinal optical coherence tomography images
Yin, X., Chao, J. R., & Wang, R. K. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.8.086020 · Cited by 128
Self-citationPhysiology of the Human Eye and Visual System
Carr, R. E. (1980) · American Journal of Ophthalmology · doi:10.1016/0002-9394(80)90140-3 · Cited by 110
Schneider, E. W., Mruthyunjaya, P., Talwar, N., Nwanyanwu, K. H., Nan, B., & Stein, J. D. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13034 · Cited by 28
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationOptical Coherence Tomography Angiography in Diabetic Retinopathy: A Prospective Pilot Study
Ishibazawa, A., Nagaoka, T., Takahashi, A., Omae, T., Tani, T., Sogawa, K., Yokota, H., & Yoshida, A. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.04.021 · Cited by 617
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Self-citationMethods and algorithms for optical coherence tomography-based angiography: a review and comparison
Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.100901 · Cited by 371
Self-citationRoisman, L., Zhang, Q., Wang, R. K., Gregori, G., Zhang, A., Chen, C.-L., Durbin, M. K., An, L., Stetson, P. F., Robbins, G., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.01.044 · Cited by 261
Self-citation
Metadata
- Authors
- Huang, Y., Zhang, Q., Thorell, M. R., An, L., Durbin, M. K., Laron, M., Sharma, U., Gregori, G., Rosenfeld, P. J., & Wang, R. K.
- Venue
- Ophthalmic Surgery, Lasers and Imaging Retina
- Publisher
- SLACK, Inc.
- Published
- 2014-09
- Volume
- 45
- Issue
- 5
- Pages
- 382-389
- ISSN
- 1542-8877 (ISSN-L)
- 2325-8160
- 2325-8179
- OpenAlex
- W2109192379
- Cited by
- 210
- References
- 11
- FWCI
- 14.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.